Inkjet printing of paraffin on paper allows low-cost point-of-care diagnostics for pathogenic fungi

被引:48
|
作者
Prabhu, Anusha [1 ]
Giri Nandagopal, M. S. [2 ]
Peralam Yegneswaran, Prakash [3 ,4 ]
Singhal, Hardik Ramesh [5 ]
Mani, Naresh Kumar [1 ,4 ]
机构
[1] Manipal Acad Higher Educ, Dept Biotechnol, Manipal Inst Technol, Manipal 576104, Karnataka, India
[2] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
[3] Manipal Acad Higher Educ, Dept Microbiol, Kasturba Med Coll Manipal, Manipal 576104, Karnataka, India
[4] Manipal Acad Higher Educ, Manipal McGill Ctr Infect Dis, Prasanna Sch Publ Hlth, Manipal 576104, Karnataka, India
[5] Manipal Acad Higher Educ, Dept Chem Engn, Manipal Inst Technol, Manipal 576104, Karnataka, India
关键词
Inkjet printing; Paraffin formulation; Candida albicans; Point-of-care; MICROFLUIDIC DEVICES; FABRICATION; WAX; IDENTIFICATION; DYNAMICS;
D O I
10.1007/s10570-020-03314-3
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
We present a high resolution, ultra-frugal printing of paper microfluidic devices using in-house paraffin formulation on a simple filter paper. The patterns printed using an office inkjet printer formed a selective hydrophobic barrier of 4 +/- 1 mu m thickness with a hydrophilic channel width of 275 mu m. These printed patterns effectively confine common aqueous solutions and solvents, which was verified by solvent compatibility studies. SEM analysis reveals that the solvent confinement is due to pore blockage in the filter paper. The fabricated paper-based device was validated for qualitative assessment ofCandida albicans(pathogenic fungi) by using a combination of L-proline beta-naphthylamide as the substrate and cinnamaldehyde as an indicator. Our studies reveal that the pathogenic fungi can be detected within 10 min with the limit of detection (LOD) of 0.86 x 10(6) cfu/mL. Owing to its simplicity, this facile method shows high potential and can be scaled up for developing robust paper-based devices for biomarker detection in resource-limited settings. [GRAPHICS] .
引用
收藏
页码:7691 / 7701
页数:11
相关论文
共 50 条
  • [31] Low-Cost, Disposable Fluorescence-Based Biorecognition System Architecture for Multiplexed Point-of-Care Molecular Diagnostics
    Smith, Joseph T.
    Obahiagbon, Uwadiae
    Ewaisha, Radwa
    Katchman, Benjamin A.
    Kaftanoglu, Korhan
    Arafa, Hany M.
    Kullman, Dixie E.
    Anderson, Karen S.
    Christen, Jennifer Blain
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 154 - 157
  • [32] Advances in paper-based point-of-care diagnostics
    Hu, Jie
    Wang, ShuQi
    Wang, Lin
    Li, Fei
    Pingguan-Murphy, Belinda
    Lu, Tian Jian
    Xu, Feng
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 585 - 597
  • [33] Unconventional Low-Cost Fabrication and Patterning Techniques for Point of Care Diagnostics
    Sharma, Himanshu
    Diep Nguyen
    Chen, Aaron
    Lew, Valerie
    Khine, Michelle
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (04) : 1313 - 1327
  • [34] Unconventional Low-Cost Fabrication and Patterning Techniques for Point of Care Diagnostics
    Himanshu Sharma
    Diep Nguyen
    Aaron Chen
    Valerie Lew
    Michelle Khine
    Annals of Biomedical Engineering, 2011, 39 : 1313 - 1327
  • [35] Low-Cost Inkjet Printing Technology for the Rapid Prototyping of Transducers
    Ando, Bruno
    Baglio, Salvatore
    Bulsara, Adi R.
    Emery, Teresa
    Marletta, Vincenzo
    Pistorio, Antonio
    SENSORS, 2017, 17 (04)
  • [36] A modular yeast biosensor for low-cost point-of-care pathogen detection
    Ostrov, Nili
    Jimenez, Miguel
    Billerbeck, Sonja
    Brisbois, James
    Matragrano, Joseph
    Ager, Alastair
    Cornish, Virginia W.
    SCIENCE ADVANCES, 2017, 3 (06):
  • [37] A Rapid, Low-Cost, Point-of-Care Test for Diabetic Peripheral Neuropathy
    Boettcher, Bonniejean
    Tracey, Brian
    Kong, Xuan
    Williams, Mike
    Gozani, Shai N.
    DIABETES, 2011, 60 : A175 - A175
  • [38] Low-cost point-of-care urine test to enhance PrEP adherence
    Leite, Iuri da Costa
    Marinho, Daniel Savignon
    LANCET HIV, 2024, 11 (08): : e497 - e498
  • [39] Preface - Low-cost devices for point-of-care, food, and environmental analysis
    Cheng, Chao-Min
    TALANTA, 2015, 145 : 1 - 1
  • [40] Inkjet catalyst printing and electroless copper deposition for low-cost patterned microwave passive devices on paper
    Cook, Benjamin S.
    Fang, Yunnan
    Kim, Sangkil
    Le, Taoran
    Goodwin, W. Brandon
    Sandhage, Kenneth H.
    Tentzeris, Manos M.
    ELECTRONIC MATERIALS LETTERS, 2013, 9 (05) : 669 - 676