Inkjet printing of paraffin on paper allows low-cost point-of-care diagnostics for pathogenic fungi

被引:48
|
作者
Prabhu, Anusha [1 ]
Giri Nandagopal, M. S. [2 ]
Peralam Yegneswaran, Prakash [3 ,4 ]
Singhal, Hardik Ramesh [5 ]
Mani, Naresh Kumar [1 ,4 ]
机构
[1] Manipal Acad Higher Educ, Dept Biotechnol, Manipal Inst Technol, Manipal 576104, Karnataka, India
[2] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
[3] Manipal Acad Higher Educ, Dept Microbiol, Kasturba Med Coll Manipal, Manipal 576104, Karnataka, India
[4] Manipal Acad Higher Educ, Manipal McGill Ctr Infect Dis, Prasanna Sch Publ Hlth, Manipal 576104, Karnataka, India
[5] Manipal Acad Higher Educ, Dept Chem Engn, Manipal Inst Technol, Manipal 576104, Karnataka, India
关键词
Inkjet printing; Paraffin formulation; Candida albicans; Point-of-care; MICROFLUIDIC DEVICES; FABRICATION; WAX; IDENTIFICATION; DYNAMICS;
D O I
10.1007/s10570-020-03314-3
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
We present a high resolution, ultra-frugal printing of paper microfluidic devices using in-house paraffin formulation on a simple filter paper. The patterns printed using an office inkjet printer formed a selective hydrophobic barrier of 4 +/- 1 mu m thickness with a hydrophilic channel width of 275 mu m. These printed patterns effectively confine common aqueous solutions and solvents, which was verified by solvent compatibility studies. SEM analysis reveals that the solvent confinement is due to pore blockage in the filter paper. The fabricated paper-based device was validated for qualitative assessment ofCandida albicans(pathogenic fungi) by using a combination of L-proline beta-naphthylamide as the substrate and cinnamaldehyde as an indicator. Our studies reveal that the pathogenic fungi can be detected within 10 min with the limit of detection (LOD) of 0.86 x 10(6) cfu/mL. Owing to its simplicity, this facile method shows high potential and can be scaled up for developing robust paper-based devices for biomarker detection in resource-limited settings. [GRAPHICS] .
引用
收藏
页码:7691 / 7701
页数:11
相关论文
共 50 条
  • [1] Inkjet printing of paraffin on paper allows low-cost point-of-care diagnostics for pathogenic fungi
    Anusha Prabhu
    M. S. Giri Nandagopal
    Prakash Peralam Yegneswaran
    Hardik Ramesh Singhal
    Naresh Kumar Mani
    Cellulose, 2020, 27 : 7691 - 7701
  • [2] LOW-COST PLAIN-PAPER COLOR INKJET PRINTING
    KEARL, DA
    ARD, MS
    HEWLETT-PACKARD JOURNAL, 1992, 43 (04): : 64 - &
  • [3] A Low-Cost Smartphone-Based Electrochemical Biosensor for Point-of-Care Diagnostics
    Sun, Alexander
    Wambach, Travis
    Venkatesh, A. G.
    Hall, Drew A.
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 312 - 315
  • [4] Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics
    Wang, Li-Ju
    Chang, Yu-Chung
    Sun, Rongrong
    Li, Lei
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI, 2018, 10486
  • [5] Low-cost, point-of-care biomarker quantification
    Piorino, Fernanda
    Patterson, Alexandra T.
    Styczynski, Mark P.
    CURRENT OPINION IN BIOTECHNOLOGY, 2022, 76
  • [6] A Dedicated Low-Cost Fluorescence Microfluidic Device Reader for Point-of-Care Ocular Diagnostics
    Pestana, Noah
    Walsh, David
    Hatch, Adam
    Hahn, Paul
    Jaffe, Glenn J.
    Murthy, Shashi K.
    Niedre, Mark
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2013, 7 (02):
  • [7] Low-cost paper diagnostics
    不详
    CHEMICAL & ENGINEERING NEWS, 2007, 85 (06) : 26 - 26
  • [8] A paper-based photoelectrochemical immunoassay for low-cost and multiplexed point-of-care testing
    Wang, Panpan
    Ge, Lei
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    Huang, Jiadong
    CHEMICAL COMMUNICATIONS, 2013, 49 (32) : 3294 - 3296
  • [9] Point-of-Care Diagnostics with Inkjet-Printed Microchips
    Lesch, A.
    Jovic, M.
    Baudoz, M.
    Zhu, Y.
    Tacchini, P.
    Gumy, F.
    Girault, H. H.
    SOLID-STATE ELECTRONICS AND PHOTONICS IN BIOLOGY AND MEDICINE 4, 2017, 77 (07): : 73 - 81
  • [10] A low-cost miniaturized potentiostat for point-of-care diagnosis
    Cruz, Andres Felipe Diaz
    Norena, Nicolas
    Kaushik, Ajeet
    Bhansali, Shekhar
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 249 - 254