Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: a systematic review and meta-analysis

被引:41
|
作者
Bhatia, Kartik Dev [1 ]
Kortman, Hans [1 ]
Orru, Emanuele [1 ]
Klostranec, Jesse M. [1 ]
Pereira, Vitor M. [1 ]
Krings, Timo [1 ,2 ,3 ]
机构
[1] Toronto Western Hosp, Joint Dept Med Imaging, Div Neuroradiol, Toronto, ON M5T 2S8, Canada
[2] Univ Hlth Network, Div Neuroradiol, Dept Med Imaging, Toronto Western Hosp, Toronto, ON, Canada
[3] Univ Hlth Network, Div Neurosurg, Dept Surg, Toronto Western Hosp, Toronto, ON, Canada
关键词
aneurysm; flow diverter; hemorrhage; stroke; complication; EMBOLIZATION DEVICE; DIVERSION; SAFETY; STENTS;
D O I
10.1136/neurintsurg-2019-014937
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Flow diverters are a breakthrough treatment for large and giant intracranial aneurysms but carry a risk of periprocedural death or major stroke. Pipeline Flex is a second-generation device that is thought to have lower complication rates because of improvements in the delivery system as well as increased operator experience. Our objective was to analyze the risk of periprocedural death or major complications using Pipeline Flex for unruptured intracranial aneurysms. Methods A systematic search of three databases was performed for studies of >= 10 treatments using Pipeline Flex for unruptured intracranial aneurysms (2014-2019) using PRISMA guidelines. Random effects meta-analysis was used to pool the rates of periprocedural (<30 days) death, major ischemic stroke, symptomatic intracranial hemorrhage, and minor stroke/transient ischemic attack. Results We included eight studies reporting 901 treatments in 879 patients. Periprocedural mortality (<30 days) was 0.8% (5/901; 95%CI 0.4% to 1.5%; I-2=0%). Rate of major complications (death, major ischemic stroke, or symptomatic intracranial hemorrhage) was 1.8% (14/901; 95%CI 1.0% to 2.7%; I-2=0%). Aneurysm size >= 10mm was a statistically significant predictor of a major complication (OR 6.4; 95%CI 2.0 to 20.7; p=0.002). Risk of a major complication in aneurysms <10mm was 0.9% (95% CI 0.3% to 1.7%; I-2=0%). The meta-analysis was limited by the predominance of anterior circulation aneurysms. Conclusion Treatment of unruptured intracranial aneurysms using the Pipeline Flex flow diverter has a low periprocedural risk of death (0.8%) or major complication (1.8%). The risk of a major complication is significantly higher for large/giant aneurysms (4.4%) and is very low for aneurysms <10mm (0.9%).
引用
收藏
页码:817 / 824
页数:8
相关论文
共 50 条
  • [41] Endovascular treatment of pediatric intracranial aneurysms: A systematic review and meta-analysis
    Bond, Brandon
    Bond, Kamila
    Ilorah, Chike
    Kattah, Jorge
    NEUROLOGY, 2017, 88
  • [42] Safety and efficacy of low profile flow diverter stents for intracranial aneurysms in small parent vessels: systematic review and meta-analysis
    Elek, Alperen
    Karagoz, Sidar
    Dindar, Gulfem Nur
    Yucel, Semra
    Cinar, Celal
    Kusbeci, Mahmut
    Ozturk, Egemen
    Oran, Ismail
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2025,
  • [43] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    D. Ley
    R. Mühl-Benninghaus
    U. Yilmaz
    H. Körner
    G. F. M. Cattaneo
    W. Mailänder
    Y-J. Kim
    B. Scheller
    W. Reith
    A. Simgen
    Clinical Neuroradiology, 2017, 27 : 335 - 343
  • [44] Flow diverters in the treatment of intracranial dissecting aneurysms: a systematic review and meta-analysis of safety and efficacy
    Amoukhteh, Melika
    Hassankhani, Amir
    Valizadeh, Parya
    Jannatdoust, Payam
    Ghozy, Sherief
    Kobeissi, Hassan
    Kallmes, David F.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (10)
  • [45] Predictive value of the systemic immune-inflammation index for periprocedural complications in flow diverter treatment for patients with intracranial aneurysms
    Huang, Jiwan
    Huang, Yaxian
    Feng, Xin
    Huang, Chi
    Huang, Mengshi
    Wen, Zhuohua
    Xu, Anqi
    Ge, Runze
    Yuan, Hao
    Shi, Hongyu
    Ma, Gengwu
    Li, Can
    Lin, Jiancheng
    Yi, Ruizhe
    Hu, Yuqi
    Jin, Yuheng
    Liang, Shuyin
    Bi, Yiming
    Su, Shixing
    Zhang, Xin
    Li, Xifeng
    Duan, Chuanzhi
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [46] Procedural Clinical Complications, Case-Fatality Risks, and Risk Factors in Endovascular and Neurosurgical Treatment of Unruptured Intracranial Aneurysms A Systematic Review and Meta-analysis
    Algra, Annemijn M.
    Lindgren, Antti
    Vergouwen, Mervyn D. I.
    Greving, Jacoba P.
    van der Schaaf, Irene C.
    van Doormaal, Tristan P. C.
    Rinkel, Gabriel J. E.
    JAMA NEUROLOGY, 2019, 76 (03) : 282 - 293
  • [47] Flow-Diversion Treatment of Unruptured Saccular Anterior Communicating Artery Aneurysms: A Systematic Review and Meta-Analysis
    Cagnazzo, F.
    Limbucci, N.
    Nappini, S.
    Renieri, L.
    Rosi, A.
    Laiso, A.
    di Carlo, D. Tiziano
    Perrini, P.
    Mangiafico, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (03) : 497 - 502
  • [48] Flow diverter treatment of posterior circulation aneurysms. A meta-analysis
    Cheng-Bin Wang
    Wen-Wen Shi
    Guang-Xu Zhang
    Hu-Chen Lu
    Jun Ma
    Neuroradiology, 2016, 58 : 391 - 400
  • [49] Headache Outcomes After Treatment of Unruptured Intracranial Aneurysm: A Systematic Review and Meta-Analysis
    Dandurand, Charlotte
    Parhar, Harman S.
    Naji, Faysal
    Prakash, Swetha
    Redekop, Gary
    Haw, Charles S.
    Prisman, Eitan
    Gooderham, Peter A.
    STROKE, 2019, 50 (12) : 3628 - 3631
  • [50] Flow diverter treatment of posterior circulation aneurysms. A meta-analysis
    Wang, Cheng-Bin
    Shi, Wen-Wen
    Zhang, Guang-Xu
    Lu, Hu-Chen
    Ma, Jun
    NEURORADIOLOGY, 2016, 58 (04) : 391 - 400