Experimental investigation on heat recovery from flue gas using falling film method

被引:7
|
作者
Min, Chunhua [1 ,2 ]
Yang, Xuguang [1 ,2 ]
He, Jing [1 ,2 ]
Wang, Kun [1 ,2 ]
Xie, Liyao [1 ,2 ]
Onwude, Daniel, I [3 ,4 ]
Zhang, Wenbin [5 ]
Wu, Hongwei [5 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[2] Hebei Univ Technol, Hebei Key Lab Thermal Sci & Energy Clean Utilizat, Tianjin 300401, Peoples R China
[3] Empa, Swiss Fed Labs Mat Sci & Technol, Lab Biomimet Membranes & Text, Lerchenfeldstr 5, CH-9014 St Gallen, Switzerland
[4] Univ Uyo, Fac Engn, Dept Agr & Food Engn, Uyo 52021, Nigeria
[5] Univ Hertfordshire, Sch Phys Engn & Comp Sci, Hatfield AL10 9AB, Herts, England
基金
中国国家自然科学基金;
关键词
Falling film; Spraying tower; Heat recovery; Flue gas; Heat transfer; WASTE HEAT; EXHAUST-GAS; ENERGY; EXCHANGER; WATER; PUMP; BOILER; SYSTEM; FLOW; ORC;
D O I
10.1016/j.tsep.2021.100839
中图分类号
O414.1 [热力学];
学科分类号
摘要
The discharge of the flue gas is rich in water vapor and its latent heat, which leads to the main heat and moisture loss for the natural gas. In this article, based on the falling film spray technology, a new test rig was set up to test the heat and moisture recovery performance from flue gas. The effects of water-air ratio and inlet air temperature on the heat transfer effectiveness were examined in a systematic manner. Four case studies, i.e. empty tower, conical baffles staggered arranged in the tower, falling film plates and baffle plates fixed on the falling film plate were designed for the current system. Experimental results showed that: (i) increasing the water-air ratio or decreasing the inlet air temperature can improve the heat transfer effectiveness; (ii) the case with conical baffles shows the highest heat transfer effectiveness. In comparison with the falling film plates, the arranged baffle plates on the falling film plate can further improve the heat transfer effectiveness; (iii) for the cases with falling plates, the heat transfer effectiveness increases with the increase of the number of the falling film plates. The maximum heat transfer effectiveness is obtained at 5 falling film plates; (iv) for the case with conical baffles, increasing the floor of the conical baffles can improve the heat transfer effectiveness. In the range of the present work, the larger central angle of the spiracle is beneficial to increase the heat transfer effectiveness. For the optimal case in the range of the present work, the heat transfer effectiveness is 41.0% higher than that for the empty tower.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Experimental investigation of water vapor condensation from flue gas in different rows of a heat exchanger model
    Poskas, Robertas
    Sirvydas, Arunas
    Mingilaite, Laura
    Jouhara, Hussam
    Poskas, Povilas
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47
  • [42] Experimental and numerical studies on novel airfoil fins heat exchanger in flue gas heat recovery system
    Han, ZengXiao
    Guo, Jiangfeng
    Zhang, Haiyan
    Chen, Junlin
    Huai, Xiulan
    Cui, Xinying
    APPLIED THERMAL ENGINEERING, 2021, 192
  • [43] EXPERIMENTAL INVESTIGATION OF FALLING-FILM REWETTING
    DUA, SS
    TIEN, CL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1978, 21 (07) : 955 - 965
  • [44] Experimental Study on a Ceramic Membrane Condenser with Air Medium for Water and Waste Heat Recovery from Flue Gas
    Teng, Da
    An, Liansuo
    Shen, Guoqing
    Zhang, Shiping
    Zhang, Heng
    MEMBRANES, 2021, 11 (09)
  • [45] Experimental study on Organic Rankine Cycle for waste heat recovery from low-temperature flue gas
    Zhou, Naijun
    Wang, Xiaoyuan
    Chen, Zhuo
    Wang, Zhiqi
    ENERGY, 2013, 55 : 216 - 225
  • [46] Improved performance of secondary heat exchanger for latent heat recovery from flue gas using mini-tubes
    Yamashita, Junpei
    Utaka, Yoshio
    APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 230 - 239
  • [47] Experimental investigation on heat transfer in horizontal-tube falling-film evaporator
    Shen, Shengqiang
    Mu, Xingsen
    Yang, Yong
    Liang, Gangtao
    Liu, Xiaohua
    DESALINATION AND WATER TREATMENT, 2015, 56 (06) : 1440 - 1446
  • [48] Flue gas desulfurization and flue gas heat utilization based on the Dresden method
    Heinrich, G.
    List, M.
    Schenk, J.
    Vogel, P.
    Luft- und Kaltetechnik Karlsruhe, 1988, 24 (04): : 199 - 203
  • [49] Experimental investigation on the heat transfer performance of falling film with deionized water on horizontal tubes
    Yan, Yan
    Weichao, Wang
    Zhao, Pan
    Xiufeng, Gao
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (05) : 1080 - 1089
  • [50] Investigation of a falling film tube bank heat exchanger with baffle design for water recovery applications
    Tang L.
    Cao X.
    Zhong W.
    Yu L.
    Yin L.
    Energy and Built Environment, 2024, 5 (05): : 817 - 828