Validation by collaborative trial of an isotope dilution liquid chromatographic tandem mass spectrometric method to determine the content of acrylamide in roasted coffee

被引:12
|
作者
Wenzl, T. [1 ]
Szilagyi, S. [1 ]
Rosen, J. [2 ]
Karasek, L. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[2] Swedish Natl Food Adm, Chem Div 1, S-75126 Uppsala, Sweden
关键词
chromatography; inter-laboratory validation; liquid chromatography/mass spectrometry (LC/MS); acrylamide; coffee; FOOD;
D O I
10.1080/02652030902939689
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method for the determination of acrylamide in roasted coffee was subjected to method validation by collaborative trial. The aim was to extend the scope of a method already standardized for the determination of acrylamide in bakery and potato products to include roasted coffee. Modifications of the already standardized method were therefore kept to a minimum. The method was based on aqueous extraction of the roasted coffee matrix and solid-phase extraction (SPE) clean-up followed by isotope dilution high-performance liquid chromatography with tandem mass spectrometric detection (LC-MS/MS). The test portion of the sample was spiked with stable isotope-labelled acrylamide and extracted on a mechanical shaker with n-hexane and water for 1 h. The sample extract was centrifuged, the organic phase discarded, and a portion of the aqueous extract further cleaned-up by SPE on an Isolute Multimode cartridge followed by a second clean-up step on an Isolute ENV+cartridge. The volume of the acrylamide-containing fraction eluted from the second SPE column was reduced by evaporation and analysed by LC-MS/MS. Three coffee samples and one aqueous acrylamide standard solution were sent to eleven laboratories from eight European Union Member States. All samples were sent as blind duplicates. Based on the reported results, the relative standard deviations for reproducibility (RSDR) were 11.5% at a level of 160 mu g kg(-1), 10.1% at a level of 263 mu g kg(-1), and 9.6% at a level of 585 mu g kg(-1). The values for repeatability (RSDr) in those materials ranged from 1.0% to 3.5%. The method performance parameters satisfied internationally accepted criteria. Hence, the method would be suitable for the enforcement of regulatory limits.
引用
收藏
页码:1146 / 1152
页数:7
相关论文
共 50 条
  • [31] Rapid liquid chromatographic - Tandem mass spectrometric method for the quantification of pentoxifylline in human plasma
    Ramakrishna, NVS
    Vishwottaml, KN
    Manoj, S
    Koteshwara, M
    Santosh, M
    Anjaneyulu, Y
    CHROMATOGRAPHIA, 2006, 63 (3-4) : 135 - 141
  • [32] Liquid chromatographic - electrospray tandem mass spectrometric method for the quantification of nimodipine in human plasma
    Nirogi, R. V. S.
    Kandikere, V. N.
    Maurya, S.
    Mudigonda, K.
    Boosi, R.
    PHARMAZIE, 2006, 61 (10): : 828 - 834
  • [33] An isotope dilution gas chromatographic-mass spectrometric method for the simultaneous assay of estrogens and phytoestrogens in urine
    Adlercreutz, H
    Kiuru, P
    Rasku, S
    Wähälä, K
    Fotsis, T
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2004, 92 (05): : 399 - 411
  • [34] Analytical method for multimycotoxins in roasted coffee samples using liquid chromatography-tandem mass spectrometry
    Choi, B.
    Kim, J. H.
    Lee, K. S.
    Kim, C., I
    Lee, J. Y.
    Park, H. M.
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2023, 30 (02): : 487 - 496
  • [35] Analysis of acrylamide in food by isotope-dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Riediker, S
    Stadler, RH
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 121 - 130
  • [36] Analysis of acrylamide in water using a coevaporation preparative step and isotope dilution liquid chromatography tandem mass spectrometry
    Chu, Shaogang
    Metcalfe, Chris D.
    ANALYTICAL CHEMISTRY, 2007, 79 (13) : 5093 - 5096
  • [37] Evaluation of an isotope dilution liquid chromatography tandem mass spectrometry method for pharmaceuticals in fish
    Du, B.
    Perez-Hurtado, P.
    Brooks, B. W.
    Chambliss, C. K.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1253 : 177 - 183
  • [38] Development and Interlaboratory Study of a Liquid Chromatography Tandem Mass Spectrometric Method for the Determination of Multiple Mycotoxins in Cereals Using Stable Isotope Dilution
    Ye, Jin
    Wu, Yu
    Guo, Qilei
    Lu, Meiling
    Wang, Songshan
    Xin, Yuanyuan
    Xie, Gang
    Zhang, Yan
    Mariappan, Meena
    Wang, Songxue
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (03) : 667 - 676
  • [39] Validation of a rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method for quantification of chlorogenic acids in roasted coffee
    Colomban, Silvia
    Guercia, Elena
    Navarini, Luciano
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (11):
  • [40] Development and validation of an analytical method for the analysis of Sterigmatocystin in roasted coffee beans and black pepper using liquid chromatography-tandem mass spectrometry
    Chung, Stephen W. C.
    Wu, Andy H. T.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (02): : 355 - 362