An experimental study on the thermal property of concrete under the load ratio condition in tunnel fire

被引:0
|
作者
Cho, Kyung Suk [1 ]
Kim, Heung Youl [1 ]
Kim, Hyung Jun [1 ]
Lee, Jae Sung [2 ]
Jung, Younghan [3 ]
机构
[1] Korea Inst Construct Technol, Gyeonggido, South Korea
[2] Hannam Univ, Daejeon, South Korea
[3] OURMRO, Daejeon, South Korea
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Under the fire, the strength of concrete decreases due to the rapid temperature increase. The ratio of the axial force under the temperature increase is a major factor in deformations of concrete structures. This study has been conducted to evaluate fire performance of the concrete lining by various fire conditions under the constant loading. The specimens are prepared according to the small scale test method in EFNARC (Specification and Guidelines for Testing of Passive Fire Protection for Concrete Tunnels Linings). To analyze the thermal properties by the strength, the adopted strengths of the specimens are 24MPa, 40MPa and 50MPa. The loading ratios are 20% and 40% of the each concrete compressive strength. MHC fire is used to study the thermal impact of the concrete by rapid temperature increase. Under the same loading ratio, the 50MPa specimen shows more cracks and spalling as time goes on as compared with the specimens of 24MPa and 40MPa.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [41] Experimental study of the interaction of concrete carbonization and chloride erosion under load
    Lian, Zibao
    FUNCTIONAL MATERIALS, 2022, 29 (04): : 559 - 566
  • [42] Experimental study on the influence of cracks on tunnel vibration under subway train load
    Ding, Zhi
    Huang, Xin
    Sun, Miao-miao
    Xu, Li-yang
    Huang, Zhang-gong
    Zhou, Qi-hui
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 142
  • [43] Experimental Study of Tunnel Fire with Natural Ventilation
    YUAN Zhong-yuan
    湖南大学学报(自然科学版), 2009, (S1) : 23 - 25
  • [44] An experimental study of smoke flow in tunnel fire
    Tongji University, Shanghai 200092, China
    不详
    Tumu Gongcheng Xuebao, 2006, 4 (95-99):
  • [45] Experimental Study of Tunnel Fire with Natural Ventilation
    YUAN ZhongyuanLEI BoCHEN PengyunSchool of Mechanical EngineeringSouthwest Jiaotong UniversityChengduSichuan China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 23 - 25
  • [46] Experimental study of tunnel fire with natural ventilation
    Yuan, Zhong-Yuan
    Lei, Bo
    Chen, Peng-Yun
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 23 - 25
  • [47] Experimental study of two-way reinforced concrete slabs under fire
    Wang, Bin
    Dong, Yuli
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (04): : 53 - 62
  • [48] Experimental Study on Dynamic Bond Behavior between Reinforcement and Concrete under Fire
    Liu, Caiwei
    Qiu, Ziwen
    Zhang, Shilong
    Yan, Liangtai
    Miao, Jijun
    Zheng, Chunying
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2024, 36 (06)
  • [49] Reliability analysis of reinforced concrete member under fire load
    Jiang, Feng-Guo
    Zhao, Jing-Lu
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2013, 43 (06): : 1500 - 1503
  • [50] Experimental Investigation of Pollutant-Luminous Environment Relation Under Tunnel Fire Condition Based on Spectral Analysis
    Quan, Yani
    Xue, Peng
    Chen, Junwei
    Wang, Shaofeng
    Zhang, Yuwei
    Ni, Zhikai
    Li, Yanfeng
    Li, Junmei
    Zhang, Nan
    Xie, Jingchao
    SUSTAINABILITY, 2024, 16 (24)