A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

被引:11
|
作者
Gyure, B. [1 ,2 ]
Markus, B. G. [1 ,2 ]
Bernath, B. [1 ,2 ]
Muranyi, F. [3 ]
Simon, F. [1 ,2 ]
机构
[1] Budapest Univ Technol & Econ, Dept Phys, H-1521 Budapest, Hungary
[2] PROSPIN, MTA BME Lendlet Spintron Res Grp, H-1521 Budapest, Hungary
[3] Fdn Res Informat Technol Soc ITIS, CH-8004 Zurich, Switzerland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 09期
基金
欧洲研究理事会;
关键词
CAVITY PERTURBATION TECHNIQUE; SPECTROSCOPY;
D O I
10.1063/1.4929865
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is pumped with the microwave radiation at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emitted microwave signal is down-converted with a microwave mixer, digitized, and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being a FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method has similar accuracy to the existing ones, which are based on sweeping or modulating the frequency of the microwave radiation. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Photonic-Assisted Microwave Frequency Measurement Using High Q-Factor Microdisk with High Accuracy
    Zhao, Mengyao
    Wang, Wenyu
    Shi, Lei
    Che, Chicheng
    Dong, Jianji
    PHOTONICS, 2023, 10 (07)
  • [42] GENERALIZED INCREMENTAL FREQUENCY RULE FOR COMPUTING Q-FACTOR OF A MICROWAVE RESONATOR
    CHU, QX
    KEXUE TONGBAO, 1988, 33 (09): : 789 - 791
  • [43] Accurate resonance frequency detection in a microwave moisture measurement
    Okamura, S
    Miyagaki, S
    Ma, Z
    JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 1998, 33 (03) : 143 - 150
  • [44] Damping Noise Induced Stochastic Resonance Improves Q-Factor of M/NEMS Resonators
    Singh, Priyanka
    Yadava, R. D. S.
    ADVANCED COMPUTATIONAL AND COMMUNICATION PARADIGMS, VOL 1, 2018, 475 : 515 - 523
  • [45] Optimum Frequency of High Q-factor Resonator for Magnetic Resonance Coupling
    Park, Jae-Hyun
    Park, Byung-Chul
    Lee, Jeong-Hae
    Ryu, Young-Ho
    Park, Eun-Seok
    Kwon, Sang-Wook
    2011 41ST EUROPEAN MICROWAVE CONFERENCE, 2011, : 61 - 63
  • [46] MEASUREMENT OF UNLOADED Q-FACTOR FROM STANDING-WAVE METHOD BY USING FREQUENCY SWEEP
    YUBA, Y
    MAKIMOTO, T
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1966, 49 (10): : 107 - +
  • [47] Method to Judge the Coupling State of the Resonator in the Q-Factor Measurement
    Zhang, Hai
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2018, PT V, 2018, 10964 : 227 - 235
  • [48] Frequency trimming and Q-factor enhancement of micromechanical resonators via localized filament annealing
    Wang, K
    Wong, AC
    Hsu, WT
    Nguyen, CTC
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 109 - 112
  • [49] COMPUTER-AIDED MEASUREMENT OF Q-FACTOR WITH APPLICATION TO QUASI OPTICAL OPEN RESONATORS
    ARORA, RK
    ADITYA, S
    XU, XZ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (05) : 863 - 866
  • [50] Q-factor estimation from surface seismic data in the time-frequency domain: A comparative analysis
    Xue, Ya-Juan
    Cao, Jun-Xing
    Wang, Xing-Jian
    Du, Hao-Kun
    Chen, Wei
    You, Jia-Chun
    Tan, Feng
    GEOPHYSICS, 2022, 87 (04) : V261 - V277