Intracardiac echocardiography in the interventional catheterization laboratory: Preliminary experience with a novel, phased-array transducer

被引:17
|
作者
Bruce, CJ [1 ]
Nishimura, RA [1 ]
Rihal, CS [1 ]
Hagler, DJ [1 ]
Higano, ST [1 ]
Seward, JB [1 ]
Holmes, DR [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2002年 / 89卷 / 05期
关键词
D O I
10.1016/S0002-9149(01)02316-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To date, intracardiac ultrasonographic guidance of interventional procedures has been limited.(1,2) The major limitation has been the poor depth of penetration of the transducers. Either catheters have had transducers with lower frequency (and thus enhanced depth penetration) that require mounting on catheters with large-bore caliber or the catheters have had smaller, higher frequency transducers that make visualization of left-sided structures impossible with the imaging catheter in the right side of the heart. Also, except for the phased-array catheter of our study, available catheters cannot provide hemodynamic assessment because they lack Doppler capabilities. Recently, a phased-array intracardiac echocardiographic catheter was introduced that has a range of frequencies (5.5 to 10 MHz) and full Doppler capability (pulsed,continuous-wave, color flow, and tissue Doppler).(3,4) Thus, this new generation imaging catheter may overcome the limitations of other available intracardiac catheters. We present preliminary results of the utility of this novel intracardiac echocardiographic catheter during interventional procedures in the cardiac catheterization laboratory.
引用
收藏
页码:635 / +
页数:7
相关论文
共 50 条
  • [41] A NOVEL INSTRUMENT FOR THE CONTROL OF A PHASED-ARRAY FOR NDE
    CAMPBELL, MA
    MCNAB, A
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 101 - 101
  • [42] Acoustic Field of Phased-Array Ultrasound Transducer with the Focus/Foci Shifting
    Lean, Hui Qi
    Zhou, Yufeng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (06) : 919 - 931
  • [43] Catheter-based intracardiac echocardiography in the interventional cardiac laboratory
    Liu, Z
    McCormick, D
    Dairywala, I
    Surabhi, S
    Goldberg, S
    Turi, Z
    Vannan, MA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (01) : 63 - 71
  • [44] Acoustic Field of Phased-Array Ultrasound Transducer with the Focus/Foci Shifting
    Hui Qi Lean
    Yufeng Zhou
    Journal of Medical and Biological Engineering, 2019, 39 : 919 - 931
  • [45] NOVEL OPTICAL TECHNIQUE FOR PHASED-ARRAY PROCESSING
    HONG, JH
    MCMICHAEL, I
    OPTICAL ENGINEERING, 1991, 30 (12) : 1976 - 1980
  • [46] A NOVEL PHASED-ARRAY ACOUSTOOPTIC BRAGG CELL
    CHEN, TS
    YAO, SK
    JOURNAL OF APPLIED PHYSICS, 1986, 60 (10) : 3732 - 3734
  • [47] A cylindrical phased-array ultrasound transducer for breast tumor thermal therapy
    Ho, CS
    Ju, KC
    Chen, YY
    Lin, WL
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1724 - 1727
  • [48] Super-Harmonic Imaging: Development of an Interleaved Phased-Array Transducer
    van Neer, Paul L. M. J.
    Matte, Guillaume
    Danilouchkine, Mikhail G.
    Prins, Christian
    van den Adel, Franc
    de Jong, Nico
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (02) : 455 - 468
  • [49] Adjustable impedance tuner for ultrasound phased-array transducer at 1.5 MHz
    de Oliveira, P. Lourenco
    Rodes, F.
    Mougenot, C.
    Moonen, C.
    ELECTRONICS LETTERS, 2009, 45 (17) : 913 - U76
  • [50] ANALYSIS OF A PULSE-ECHO ULTRASOUND TAPERED PHASED-ARRAY TRANSDUCER
    BENKESER, PJ
    GOFF, EF
    RICE, WO
    ULTRASONICS, 1987, 25 (06) : 376 - 376