Barrel calorimeter of the CMD-3 detector

被引:6
|
作者
Anisenkov, A. V. [1 ]
Aulchenko, V. M. [1 ,2 ]
Barkov, L. M. [1 ]
Bashtovoy, N. S. [1 ]
Bondar, A. E. [1 ,2 ]
Epifanov, D. A. [1 ,4 ]
Epshteyn, L. B. [1 ,3 ]
Erofeev, A. L. [1 ]
Grebenuk, A. A. [1 ,2 ]
Ignatov, F. V. [1 ]
Karpov, S. V. [1 ]
Khazin, B. I. [1 ,2 ]
Kovalenko, O. A. [1 ,2 ]
Kozyrev, A. N. [1 ]
Kuzmin, A. S. [1 ]
Logashenko, I. B. [1 ,2 ]
Mikhailov, K. Yu. [1 ,2 ]
Pestov, Yu. N. [1 ]
Pivovarov, S. G. [1 ]
Popov, A. S. [1 ,2 ]
Razuvaev, G. P. [1 ]
Ruban, A. A. [1 ]
Ryzhenenkov, A. E. [1 ,2 ]
Shebalin, V. E. [1 ]
Shemyakin, D. N. [1 ,2 ]
Shwartz, B. A. [1 ,2 ]
Solodov, E. P. [1 ,2 ]
Titov, V. M. [1 ]
Talyshev, A. A. [1 ,3 ]
Yudin, Yu. V. [1 ]
机构
[1] SB RAS, Budker Inst Nucl Phys, Novosibirsk 630090, Russia
[2] Novosibirsk State Univ, Novosibirsk 630090, Russia
[3] Novosibirsk State Tech Univ, Novosibirsk 630092, Russia
[4] Tokyo Inst Technol, Tokyo 1528550, Japan
关键词
VEPP-2000; CMD-3; Liquid Xenon calorimeter; Scintillation crystals; LIQUID XENON; VEPP-2000; COLLIDER;
D O I
10.1016/j.nima.2013.07.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since 2010 the CMD-3 detector has been collecting data at the e(+) e(-) collider VEPP-2000 at Budker Institute of Nuclear Physics. CMD-3 is a general purpose detector designed to study e(+) e annihilation into hadrons in the wide energy range root s = 0.3-2 GeV, The CMD-3 barrel electromagnetic calorimeter consists of two subsystems: closest to the beam pipe is the Liquid Xenon calorimeter and the outer one is based on CsI scintillation crystals. The design of the calorimeter and its current performance are presented. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:463 / 465
页数:3
相关论文
共 50 条
  • [21] Upgrade of the CMD-3 BGO Endcap Calorimeter
    Grigoriev, D. N.
    Akhmetshin, R. R.
    Kazanin, V. F.
    Kuzmenko, A. E.
    Yudin, Yu V.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1143 - 1146
  • [22] Drift chamber for the CMD-3 detector
    Grancagnolo, F.
    Fiore, G.
    Ignatov, F. V.
    Karavdina, A. V.
    Khazin, B. I.
    Miccoli, A.
    Pivovarov, S. G.
    Popov, A. S.
    Ruban, A. A.
    Sibidanov, A. L.
    Snopkov, I. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 105 - 106
  • [23] Electromagnetic calorimeters of the CMD-3 detector
    Epifanov, Denis
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [24] CMD-3 Detector Offline Software Development
    Anisenkov, A.
    Ignatov, F.
    Pirogov, S.
    Sibidanov, A.
    Viduk, S.
    Zaytsev, A.
    17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [25] Processing of the signals from the liquid-xenon calorimeter of the CMD-3 detector for timing measurements
    Epshtein, L. B.
    Yudin, Yu V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2012, 55 (05) : 551 - 560
  • [26] Recent results from the CMD-3 detector
    Lukin, P. A.
    Akhmetshin, R. R.
    Amirkhanov, A. N.
    Anisenkov, A., V
    Aulchenko, V. M.
    Banzarov, V. Sh
    Bashtovoy, N. S.
    Berkaev, D. E.
    Bondar, A. E.
    Bragin, A., V
    Eidelman, S., I
    Epifanov, D. A.
    Epshtein, L. B.
    Erofeev, A. L.
    Fedotovich, G., V
    Gayazov, S. E.
    Grebenuk, A. A.
    Gribanov, S. S.
    Grigoriev, D. N.
    Ignatov, F., V
    Ivanov, V. L.
    Karpov, V
    Kazanin, V. F.
    Koop, I. A.
    Kirpotin, A. N.
    Korobov, A. A.
    Kozyrev, A. N.
    Kozyrev, E. A.
    Krokovny, P. P.
    Kuzmenko, A. E.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu
    Okhapkin, V. S.
    Otboev, A., V
    Pestov, Yu N.
    Popov, A. S.
    Razuvaev, G. P.
    Rogovsky, Yu A.
    Ruban, A. A.
    Ryskulov, N. M.
    Ryzhenenkov, A. E.
    Semenov, A., V
    Senchenko, A., I
    Shatunov, P. Yu
    Shatunov, Yu M.
    Shebalin, V. E.
    Shemyakin, D. N.
    Shwartz, B. A.
    Shwartz, D. B.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2020, 309 : 99 - 102
  • [27] Processing of the signals from the liquid-xenon calorimeter of the CMD-3 detector for timing measurements
    L. B. Epshtein
    Yu. V. Yudin
    Instruments and Experimental Techniques, 2012, 55 : 551 - 560
  • [28] The electronics for TOF system of the CMD-3 detector
    Kozyrev, A. N.
    Ruban, A. A.
    Amerhanov, A. N.
    Fedotovich, G. V.
    Gribanov, S. S.
    Popov, A. S.
    Ryskulov, N. M.
    Ryzhenenkov, A. E.
    Shemyakin, D. N.
    Tolmachev, S. S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [29] CMD-3 detector for VEPP-2000
    Fedotovich, G. V.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 162 : 332 - 338
  • [30] Architecture of the system of registration and triggering of the CMD-3 detector
    Aulchenko V.M.
    Epifanov D.A.
    Kozyrev A.N.
    Logashenko I.B.
    Popov A.S.
    Ruban A.A.
    Selivanov A.N.
    Talyshev A.A.
    Titov V.M.
    Yudin Y.V.
    Epshteyn L.B.
    Optoelectronics, Instrumentation and Data Processing, 2015, 51 (01) : 24 - 30