Durability Evaluation of Headed Shear Studs Embedded in Ultrahigh-Performance Concrete via Electrochemical Corrosion

被引:16
|
作者
Kruszewski, Dominic [1 ]
Zaghi, Arash E. [2 ]
Wille, Kay [2 ]
机构
[1] WSP USA, 1 Penn Plaza, New York, NY 10119 USA
[2] Univ Connecticut, Dept Civil & Environm Engn, 261 Glenbrook Rd, Storrs, CT 06269 USA
关键词
Corrosion damage; Accelerated corrosion; Push-out; Shear studs; Shear connector; Ultrahigh-performance (UHPC); Faraday's theory; BEHAVIOR; DESIGN;
D O I
10.1061/(ASCE)BE.1943-5592.0001401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion is one of the most common sources of deterioration for steel girder bridges, especially in regions where deicing chemicals are frequently used. Over time, the end-bearing capacity of the girder is significantly reduced as the corrosion results in section loss of the web plate and flanges. A novel repair method utilizing ultrahigh-performance concrete (UHPC) has been proposed to restore the bearing strength of corroded girder ends. In this method, shear studs are welded to the intact area of the web plate near the bearing and embedded in a UHPC cast to create an alternative load path. As part of a multiyear research project, extensive experimental and analytical studies have proven the structural effectiveness of this repair. Yet, the durability of the repair needs to be investigated to gain confidence in its long-term performance. This article presents the results of push-out experiments performed on six specimens after subjecting them to accelerated electrochemical corrosion. The objective was to evaluate parameters relevant to the repair to investigate the effect of (a) the presence of chlorides before the repair is applied and (b) penetration of chlorides after losing the bond between the UHPC and web plate due to cyclic loading. In addition, the durability behavior of high-strength concrete (HSC) as the repair material was compared to UHPC. The results suggest that accelerated electrochemical corrosion induced onto a push-out sample did not reduce the mechanical performance of the headed studs during the limited time of exposure. These results were obtained for both UHPC and HSC. Although the electrochemical process accelerated the corrosion of the exposed steel material, it did not expedite or facilitate the penetration of ions into the concrete. (c) 2019 American Society of Civil Engineers.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Modeling the Shear Connection in Adjacent Box-Beam Bridges with Ultrahigh-Performance Concrete Joints. II: Load Transfer Mechanism
    Sargand, Shad M.
    Walsh, Kenneth K.
    Hussein, Husam H.
    Al Rikabi, Fouad T.
    Steinberg, Eric P.
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (08)
  • [42] Bayesian-Network-Based Evaluation for Corrosion State of Reinforcements Embedded in Concrete by Multiple Electrochemical Indicators
    Guo, Zengwei
    Fan, Jianhong
    Feng, Shengyang
    Wu, Chaoyuan
    Yao, Guowen
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [43] Shear Performance of Prefabricated Steel Ultra-High-Performance Concrete (UHPC) Composite Beams under Combined Tensile and Shear Loads: Single Embedded Nut Bolts vs. Studs
    Wang, Guodong
    Xian, Bingxiong
    Ma, Feiyang
    Fang, Shu
    BUILDINGS, 2024, 14 (08)
  • [44] Effect of migratory corrosion inhibitors on the durability of chloride-contaminated rereinforced concrete-electrochemical performance and penetration concentration
    School of Civil Engineering, Yantai University, Yantai 264005, China
    不详
    不详
    Kuei Suan Jen Hsueh Pao, 2009, 7 (1254-1260):
  • [45] Performance Evaluation of Longitudinal Ultrahigh-Performance Concrete Closure Pour Connection for Use in Modular Bridge Construction: Pairwise Comparison of Capacity and Ductility at Failure Limit State
    Deng, Yaohua
    Phares, Brent M.
    Putz, Andrew J.
    Carter, Curtis
    Nop, Michael
    Bierwagen, Dean
    TRANSPORTATION RESEARCH RECORD, 2016, (2592) : 65 - 75
  • [46] DURABILITY OF STEEL IN REINFORCED-CONCRETE STRUCTURES IN EGYPT .3. NEW ACCELERATED ELECTROCHEMICAL TEST FOR EVALUATION OF CORROSION SUSCEPTIBILITY OF REINFORCEMENT
    MOUSSA, AA
    GAHFAR, IA
    KAMAL, AA
    ZAHRAN, MG
    EGYPTIAN JOURNAL OF CHEMISTRY, 1972, 15 (06): : 577 - 588
  • [47] Effect of nano-silica and nano-waste material on durability and corrosion rate of steel reinforcement embedded in high-performance concrete
    Tawfik T.A.
    El-Yamani M.A.
    Abd El-Aleem S.
    Serag Gabr A.
    Abd El-Hafez G.M.
    Asian Journal of Civil Engineering, 2019, 20 (1) : 135 - 147
  • [48] Seismic Performance Evaluation of Corrosion-Damaged Reinforced Concrete Columns Controlled by Shear Based on Experiment and FEA
    Kim, Young-Shik
    Lee, Bok-Gi
    Jung, Ju-Seong
    Lee, Kang-Seok
    MATERIALS, 2022, 15 (18)
  • [49] Evaluation of the nano silica and nano waste materials on the corrosion protection of high strength steel embedded in ultra-high performance concrete
    Sahar A. Mostafa
    Mohamed M. EL-Deeb
    Ahmed A. Farghali
    A. Serag Faried
    Scientific Reports, 11
  • [50] Evaluation of the nano silica and nano waste materials on the corrosion protection of high strength steel embedded in ultra-high performance concrete
    Mostafa, Sahar A.
    EL-Deeb, Mohamed M.
    Farghali, Ahmed A.
    Faried, A. Serag
    SCIENTIFIC REPORTS, 2021, 11 (01)