Implants made of commercially pure titanium (cpTi) are widely and successfully used in dentistry. For certain indications, diameter-reduced Ti alloy implants with improved mechanical strength are highly desirable. The aim was to compare the osseointegration of titanium-zirconium (TiZr) and cpTi implants with a modified sandblasted and acid-etched (SLActive) surface and with a Ti6Al4V alloy that was sand-blasted and acid-washed. Cylindrical implants with two, 0.75 mm deep, circumferential grooves were placed in the maxilla of miniature pigs and allowed to heal for 1, 2, 4 and 8 weeks. Undecalcified toluidine blue-stained ground sections were produced. Surface topography, area fraction of tissue components, and bone-to-implant contact (BIC) were determined. All materials showed significantly different surface roughness parameters. The amount of new bone within the implant grooves increased over time, without significant differences between materials. However, BIC values were significantly related to the implant material and the healing period. For TiZr and cpTi implants, the BIC increased over time, reaching values of 59.38 % and 76.15 % after 2 weeks, and 74.50 % and 84.67 % after 8 weeks, respectively. In contrast, the BIC for Ti6Al4V implants peaked with 42.29 % after 2 weeks followed by a decline to 28.60 % at 8 weeks. Significantly more surface was covered by multinucleated giant cells on Ti6Al4V implants after 4 and 8 weeks. In conclusion, TiZr and cpTi implants showed faster osseointegration than Ti6Al4V implants. Both chemistry and surface topography might have influenced the results. The use of diameter-reduced TiZr implants in more challenging clinical situations warrants further documentation in long-term clinical studies.
引用
收藏
页码:273 / 288
页数:16
相关论文
共 50 条
  • [41] CRANIAL BONE APPOSITION AND INGROWTH IN A POROUS NICKEL-TITANIUM IMPLANT
    SIMSKE, SJ
    SACHDEVA, R
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (04): : 527 - 533
  • [42] Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis
    Altuna, P.
    Lucas-Taule, E.
    Gargallo-Aibiol, J.
    Figueras-Alvarez, O.
    Hernandez-Alfaro, F.
    Nart, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (07) : 842 - 850
  • [43] One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes
    Zembic, Anja
    Tahmaseb, Ali
    Jung, Ronald E.
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (07) : e60 - e67
  • [44] The influence of surface energy of titanium-zirconium alloy on osteoblast cell functions in vitro
    Sista, Subhash
    Wen, Cui'e
    Hodgson, Peter D.
    Pande, Gopal
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2011, 97A (01) : 27 - 36
  • [45] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Paola Herrera-Pérez
    Ana María García-De-La-Fuente
    Eztizen Andia-Larrea
    Xabier Marichalar-Mendia
    José Manuel Aguirre-Urizar
    Luis Antonio Aguirre-Zorzano
    BMC Oral Health, 24
  • [46] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Herrera-Perez, Paola
    Garcia-De-La-Fuente, Ana Maria
    Andia-Larrea, Eztizen
    Marichalar-Mendia, Xabier
    Aguirre-Urizar, Jose Manuel
    Aguirre-Zorzano, Luis Antonio
    BMC ORAL HEALTH, 2024, 24 (01)
  • [47] Dose-response effect of chlorhexidine on a multispecies oral biofilm formed on pure titanium and on a titanium-zirconium alloy
    Silva Souza, Joao Gabriel
    Lima, Carolina Veloso
    Costa Oliveira, Barbara Emanoele
    Ricomini-Filho, Antonio Pedro
    Faveri, Marcelo
    Sukotjo, Cortino
    Feres, Magda
    Del Bel Cury, Altair Antoninha
    Ricardo Barao, Valentim Adelino
    BIOFOULING, 2018, 34 (10) : 1175 - 1184
  • [48] Survival rate of titanium-zirconium narrow diameter dental implants versus commercially pure titanium narrow diameter dental implants: A systematic review
    Iegami, Carolina Mayumi
    Uehara, Priscila Nakasone
    Sesma, Newton
    Pannuti, Claudio Mendes
    Neto, Pedro Tortamano
    Mukai, Marcio Katsuyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (06) : 1015 - 1022
  • [49] Cell biological responses of osteoblasts on anodized nanotubular surface of a titanium-zirconium alloy
    Sista, Subhash
    Nouri, Alireza
    Li, Yuncang
    Wen, Cuie
    Hodgson, Peter D.
    Pande, Gopal
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2013, 101 (12) : 3416 - 3430
  • [50] Stability and Marginal Bone Level Changes of SLActive Titanium-Zirconium Implants Placed with Flapless Surgery: A Prospective Pilot Study
    Altinci, Pinar
    Can, Gulsen
    Gunes, Onur
    Ozturk, Caner
    Eren, Hakan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (06) : 1193 - 1199