Oxide Layer Mass Determination at the Silicon Sphere of the Avogadro Project

被引:19
|
作者
Busch, Ingo [1 ]
Danzebrink, Hans-Ulrich [1 ]
Krumrey, Michael [1 ]
Borys, Michael [1 ]
Bettin, Horst [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
Avogadro; density; ellipsometry; flotation; silicon; silicon oxide; surface; X-ray reflectometry (XRR); X-RAY REFLECTOMETRY; DENSITY DETERMINATION; SI;
D O I
10.1109/TIM.2008.2007037
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Within the International Avogadro Project, two spheres of highly enriched Si-28 crystals have been produced to perform new determination of Avogadro constant N-A. The mass of the oxide layer of the spheres has to be measured as one of the critical tasks. For this purpose, a method consisting of precise thickness measurements and density determinations is proposed and tested. Part of this procedure is the thermal oxidation of the Si spheres to produce a SiO2 layer with a well-defined structure and stoichiometry. Consecutively, its thickness is determined by a combination of X-ray reflectometry (XRR) for absolute thickness determination and spectral ellipsometry for mapping. Starting with the analysis of the assumed uncertainty budget, the allowed uncertainties of each part of the procedure were estimated to realize the required uncertainty in an oxide layer mass of 10 mu g. The measurements at the test spheres have been carried out to show that an uncertainty of u(d) = 0.1 urn for the thickness measurements directly at the silicon spheres can be achieved, e.g., the thickness of the SiO2 layer at the PTB-01 sphere at a (100) lattice plane has been determined to be d = 6.2(1) nm. The second major part of the procedure described in this paper Is the determination of the density or the oxide layer of the sphere by pressure of floatation at an additional test sphere. A value of rho = 2228(18) kg /m(3) has been determined and confirmed in a remeasurement, with the resulting value of rho = 2223 (15) kg/m(3).
引用
收藏
页码:891 / 896
页数:6
相关论文
共 50 条
  • [21] Influence of the optical quality of the interferometer optics on the diameter measurement of the Avogadro silicon sphere
    Nicolaus, R. Arnold
    Bartl, Guido
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 412 - 413
  • [22] Determination of silicon oxide layer thickness by time-of-flight secondary ion mass spectroscopy
    Brox, O
    Iltgen, K
    Hellweg, S
    Benninghoven, A
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1999, 17 (05): : 2191 - 2192
  • [23] Molar-mass measurement of a 28Si-enriched silicon crystal for determination of the Avogadro constant
    Narukawa, Tomohiro
    Hioki, Akiharu
    Kuramoto, Naoki
    Fujii, Kenichi
    METROLOGIA, 2014, 51 (03) : 161 - 168
  • [24] The Avogadro constant determination via enriched silicon-28
    Becker, P.
    Friedrich, H.
    Fujii, K.
    Giardini, W.
    Mana, G.
    Picard, A.
    Pohl, H-J
    Riemann, H.
    Valkiers, S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (09)
  • [25] DETERMINATION OF SILICON EPITAXIAL LAYER THICKNESS THROUGH A DEPOSITED OXIDE LAYER
    RUSSELL, LK
    LEGAT, WH
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1966, 113 (03) : C64 - &
  • [26] Evaluation of the molar volume of silicon crystals for a determination of the Avogadro constant
    Fujii, K
    Waseda, A
    Kuramoto, N
    Tanaka, M
    Valkiers, S
    Taylor, P
    Kessel, R
    De Biévre, P
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 560 - 561
  • [27] Evaluation of the molar volume of silicon crystals for a determination of the Avogadro constant
    Fujii, K
    Waseda, A
    Kuramoto, N
    Mizushima, S
    Tanaka, M
    Valkiers, S
    Taylor, P
    Kessel, R
    De Bièvre, P
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 646 - 651
  • [28] Measuring the molar mass of silicon for a better avogadro constant: Reduced uncertainty
    Gonfiantini, R
    DeBievre, P
    Valkiers, S
    Taylor, PDP
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 566 - 571
  • [29] Absolute silicon molar mass measurements, the Avogadro constant and the redefinition of the kilogram
    Vocke, R. D., Jr.
    Rabb, S. A.
    Turk, G. C.
    METROLOGIA, 2014, 51 (05) : 361 - 375
  • [30] Prompt (n,gamma)-spectrometry for the isotopic analysis of silicon crystals for the Avogadro Project
    Rottger, S
    Paul, A
    Keyser, U
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 560 - 562