The routine leukocyte differential flow cytometry HematoFlow method: A new flagging system for automatic validation

被引:12
|
作者
Allou, Kaoutar [1 ]
Vial, Jean-Philippe [1 ]
Bene, Marie C. [2 ]
Lacombe, Francis [1 ]
机构
[1] Univ Hosp Bordeaux, Haut Leveque Hosp, Pessac, France
[2] Univ Hosp Nantes, Nantes, France
关键词
flow cytometry; hematology; immunophenotyping; multiparameter analysis; peripheral blood; BLOOD; ENUMERATION;
D O I
10.1002/cyto.b.21242
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The complete blood cell count and white blood cell differential are the first step in the biological diagnosis of hematological diseases. Both are currently performed by automated instruments which control data and produce alerts. If such flags are activated, the automated differential cannot be validated and the operator must activate a visual blood smear review. Microscopic examination is still today the reference method despite its lack of sensitivity and reproducibility. The HematoFlow (Beckman Coulter) system is the first flow cytometry commercialized method designed for the routine differential. Using six markers in five colors and an automated gating strategy, it provides differentials proven to be reliable for 17 leukocyte subpopulations detection. Relying first on a retrospective analysis of 6,462 blood samples processed by HematoFlow, thresholds were determined to detect the presence of immature granulocytes and/or blast cells. All possible gating strategy misclassifications of leukocyte subpopulations were then summarized in a systematic nomenclature leading to the development of an original flag system based on the detection of aberrant localization of cell events in specific new bivariate histograms. Ultimately, more than 50% of the results could be automatically validated using the HematoFlow system, without any false negative, thereby dramatically contributing to an important decrease of technicians' workload. Moreover a noticeable help was given for smear review interpretation and new immunological flags led to the confirmation of blood disease after classical immunophenotyping. These results were confirmed in a second prospective study including 15,335 cases, where more than 50% of the results were automatically validated by this new flag system. MFC stands as being more and more essential for analyzing differentials in routine and this new flag system could greatly improve its implementation. (c) 2015 International Clinical Cytometry Society
引用
收藏
页码:375 / 384
页数:10
相关论文
共 50 条
  • [1] HEMATOFLOW®: A FLAGGING SYSTEM TOWARD AN AUTOMATIC VALIDATION
    Allou, Kaoutar
    Vial, Jean-Philippe
    Lacombe, Francis
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 44 - 44
  • [2] CONCLUSIVE IMPROVEMENT OF AN AUTOMATIC FLAGGING SYSTEM IN HEMATOFLOW
    Allou, Kaoutar
    Lacombe, Francis
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 39 - 40
  • [3] Place of immunophenotyping in routine differential leukocyte analysis. A practical example with Hematoflow®
    Francis, Lacombe
    Jean-Philippe, Vial
    Kaoutar, Allou
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 5 - 6
  • [4] Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method
    Jo, Yongjun
    Kim, Soo Hwa
    Koh, Kwangsang
    Park, Jongmoon
    Shim, Yang Bo
    Lim, Jihyang
    Kim, Yonggoo
    Park, Yeon-Joon
    Han, Kyungja
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2011, 31 (03): : 131 - 137
  • [5] Verification of a quantitative method: complete blood count by flow cytometry, the HematoFlow™ system (Beckman Coulter)
    Vergnolle, Ines
    Allou, Kaoutar
    Lacombe, Francis
    Mahon, Francois Xavier
    Vial, Jean-Philippe
    ANNALES DE BIOLOGIE CLINIQUE, 2016, 74 (05) : 617 - 631
  • [6] Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer
    Kim, J. -E.
    Kim, B. -R.
    Woo, K. -S.
    Han, J. -Y.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 (05) : 547 - 550
  • [7] Preliminary evaluation of a new flow cytometry method for the routine hematology workflow
    Seghezzi, Michela
    Moioli, Valentina
    Previtali, Giulia
    Manenti, Barbara
    Lopez, Ramon-Simon
    Kono, Mari
    Tirloni, Ezio
    Alessio, Maria Grazia
    Buoro, Sabrina
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (10) : 1608 - 1622
  • [8] Flow Cytometry Method Validation Protocols
    Selliah, Nithianandan
    Nash, Veronica
    Eck, Steven
    Green, Cherie
    Oldaker, Teri
    Stewart, Jennifer
    Vitaliti, Alessandra
    Litwin, Virginia
    CURRENT PROTOCOLS, 2023, 3 (08):
  • [9] Development and validation of a flow cytometry method to examine circulating leukocyte subpopulations in barramundi ( Lates calcarifer )
    Titus, Jaison
    Nayak, Sagar
    Sultan, Eliya
    Gershoni-Yahalom, Orly
    Sinai, Tamar
    Zilberg, Dina
    Rosental, Benyamin
    COMPARATIVE IMMUNOLOGY REPORTS, 2024, 6
  • [10] AUTOMATIC MICROSCOPE SYSTEM FOR DIFFERENTIAL LEUKOCYTE COUNTING
    DEW, B
    KING, T
    MIGHDOLL, D
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1974, 22 (07) : 685 - 696