Evaluation of the dose variation for prostate heavy charged particle therapy using four-dimensional computed tomography

被引:5
|
作者
Kumagai, Motoki [1 ]
Okada, Tohru [1 ]
Mori, Shinichiro [1 ]
Kandatsu, Susumu [1 ]
Tsuji, Hiroshi [1 ]
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, Chiba 2638555, Japan
关键词
charged particle therapy; 4DCT; intrafractional motion; prostate; REAL-TIME; HYPOFRACTIONATED RADIOTHERAPY; CONFORMAL RADIOTHERAPY; PERFORMANCE EVALUATION; ION RADIOTHERAPY; CT-SCANNER; MOTION; CANCER; IRRADIATION; TRACKING;
D O I
10.1093/jrr/rrs106
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We quantified dose variation effects due to respiratory-induced intrafractional motion in conventional carbon-ion prostate treatment by using four-dimensional computed tomography (4DCT). 4DCT scans of 20 patients were acquired under free-breathing conditions using a 256 multi-slice CT scanner. The clinical target volume (CTV) was defined as the prostate and the seminal vesicle. Two types of planning target volumes (PTVs) were defined to minimize excessive dose to the rectum. The first PTV (= PTV1) was calculated by adding a 3D uniform margin to the CTV. The second PTV (= PTV2) was cut in a straight line from the top surface of the rectum from PTV1. Compensating boli were designed for the respective PTVs at the peak-exhalation phase, and carbon-ion dose distributions for a single respiratory cycle were calculated using these boli. Dose conformation to prostate, CTV, PTV1 and PTV2 were unchanged for all respiratory phases. The dose for > 95% volume irradiation (D95) was 97.7% for prostate, 92.5% for CTV, 74.1% for PTV1 and 96.1% for PTV2 averaged over all patients. The rectum volume at inhalation phase receiving < 50% of the prescribed dose was smaller than the planning dose due to the abdominal thickness variation. The target dose is not affected by intrafractional respiration in carbon-ion prostate treatment. Small dose variations, however, were observed due to respiratory-induced abdominal thickness variation; therefore the geometrical changes should be considered for prostate particle therapy.
引用
收藏
页码:357 / 366
页数:10
相关论文
共 50 条
  • [21] Semiautomated four-dimensional computed tomography segmentation using deformable models
    Ragan, D
    Starkschall, G
    McNutt, T
    Kaus, M
    Guerrero, T
    Stevens, CW
    MEDICAL PHYSICS, 2005, 32 (07) : 2254 - 2261
  • [22] Use of four-dimensional computed tomography in conformal therapy planning for lung cancer
    Wahab, S
    Low, D
    ElNaqa, I
    Parikh, P
    Nystrom, M
    Bradley, J
    Mutic, S
    Dempsey, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1364 - 1364
  • [23] Four-dimensional evaluation of a giant pseudo-aneurysm by multislice computed tomography
    Mollet, NR
    Cademartiri, F
    Runza, G
    Belgrano, M
    Baks, T
    Meijboom, WB
    de Feyter, PJ
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (06): : 667 - 668
  • [24] Four-Dimensional Evaluation of a Giant Pseudo-Aneurysm by Multislice Computed Tomography
    Nico R. Mollet
    Filippo Cademartiri
    Giuseppe Runza
    Manuel Belgrano
    Timo Baks
    Willem B. Meijboom
    Pim J. de Feyter
    The International Journal of Cardiovascular Imaging, 2005, 21 : 667 - 668
  • [25] Utility of four-dimensional computed tomography for analysis of intrafractional and interfractional variation in lung volumes
    Rosen, Benjamin
    Starkschall, George
    Britton, Keith
    Mohan, Radhe
    Cox, James D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : 288 - 294
  • [26] First clinical evaluation of breathing controlled four-dimensional computed tomography imaging
    Szkitsak, Juliane
    Werner, Rene
    Fernolendt, Susanne
    Schwarz, Annette
    Ott, Oliver J.
    Fietkau, Rainer
    Hofmann, Christian
    Bert, Christoph
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 20 : 56 - 61
  • [27] Variability of four-dimensional computed tomography patient models
    Sonke, Jan-Jakob
    Lebesque, Joos
    Van Herk, Marcel
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 590 - 598
  • [28] Four-Dimensional Computed Tomography for Localisation of Parathyroid Adenomas
    Leung, H. S.
    Liu, S. Y. W.
    Wong, K. T.
    Yu, S. M.
    King, A. D.
    HONG KONG JOURNAL OF RADIOLOGY, 2023, 26 (03): : 185 - 193
  • [29] Four-dimensional Computed Tomography and Trigger Lunate Syndrome
    Troupis, John M.
    Amis, Benjamin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 639 - 643
  • [30] Four-dimensional cardiac imaging with multislice computed tomography
    Nieman, K
    van Ooijen, P
    Rensing, B
    Oudkerk, M
    de Feyter, PJ
    CIRCULATION, 2001, 103 (12) : E62 - E62