Development of a highly sensitive, second antibody format chemiluminescence enzyme immunoassay for the determination of 17β-estradiol in wastewater

被引:72
|
作者
Zhao, LX
Lin, JM [1 ]
Li, ZJ
Ying, XT
机构
[1] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Ecoenvironm Sci Res Ctr, Beijing 100085, Peoples R China
[2] Beijing Acad Sci Technol, Kemei Dongya Inst Biotech, Beijing 100012, Peoples R China
基金
中国国家自然科学基金;
关键词
17; beta-estradiol; fluorescein-iso-thiocyanate (FITC)-anti-FITC system; chemiluminescence immunoassay; wastewater;
D O I
10.1016/j.aca.2005.11.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a highly sensitive chemiluminescence enzyme immunoassay (CLEIA) method for the determination of 17 beta-estradiol (E2) in the wastewater was developed, which used the fluorescein-iso-thiocyanate (FITC)-anti-FITC system as solid phase and the biotin-streptavidin system as signal amplification system, with the highly sensitive 4-methoxy-4-(3-phosphatephenyl)-spiro-(1,2-dioxetane-3,2'-adamantane) (AMPPD)-alkaline phosphatase (ALP) system as chemiluminescence detection system. The specific polyclonal antibody was produced against a conjugate of estradiol-bovine serum albumin (BSA), biotinoyl-diaminodioxaoctane-estradiol conjugate was synthesized. The specificity of anti-E2 antibody was also studied. The results showed that anti-E2 antibody has no cross-reactions for estriol, ethinyl E2, estrone commonly coexisting with E2 in the wastewater. Samples were prepared with solid-phase extraction using C-18 cartridges for the removal of matrix effects. The linear range was 2.5-1600 pg ml(-1) and detection limit was 1.5 pg ml(-1). As our known of knowledge, the method was more sensitive for the determination of E2 in water compared with other immunoassay methods. Recoveries were in the range of 80-110% in spiked tap water and wastewater. This method has been successfully used for the detection of E2 in wastewater, compared with the commercially radioimmunoassay (RIA) kit, the correlation was good. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 50 条
  • [41] HIGHLY SENSITIVE AND SPECIFIC ENZYME-IMMUNOASSAY METHOD FOR OESTRADIOL-17-BETA
    EXLEY, D
    ABUKNESHA, R
    FEBS LETTERS, 1978, 91 (02) : 162 - 165
  • [42] Development of sensitive direct chemiluminescent enzyme immunoassay for the determination of dihydroartemisinin in plasma
    Laura Zehnacker
    Marie-Claire Nevers
    Véronique Sinou
    Dominique Parzy
    Christophe Créminon
    Daniel Parzy
    Stéphane Azoulay
    Analytical and Bioanalytical Chemistry, 2015, 407 : 7823 - 7830
  • [43] DEVELOPMENT OF A SENSITIVE ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF VINPOCETINE IN HUMAN PLASMA
    RECK, B
    DINGLER, E
    LOHMANN, A
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1992, 42-2 (10): : 1171 - 1174
  • [44] Development of sensitive direct chemiluminescent enzyme immunoassay for the determination of dihydroartemisinin in plasma
    Zehnacker, Laura
    Nevers, Marie-Claire
    Sinou, Veronique
    Parzy, Dominique
    Creminon, Christophe
    Parzy, Daniel
    Azoulay, Stephane
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (25) : 7823 - 7830
  • [45] Development of a highly sensitive magnetic particle-based chemiluminescence enzyme immunoassay for thyroid stimulating hormone and comparison with two other immunoassays
    Xiao, Qin
    Li, Haifang
    Lin, Jin-Ming
    CLINICA CHIMICA ACTA, 2010, 411 (15-16) : 1151 - 1153
  • [46] Development of highly sensitive chemiluminescence enzyme immunoassay based on the anti-recombinant HC subunit of botulinum neurotoxin type A monoclonal antibodies
    Liu, Zhijia
    Song, Chaojun
    Li, Yongming
    Liu, Fei
    Zhang, Kui
    Sun, Yuanjie
    Li, Haitao
    Wei, Yuying
    Xu, Zhuwei
    Zhang, Chunmei
    Yang, Angang
    Xu, Zhikai
    Yang, Kun
    Jin, Boquan
    ANALYTICA CHIMICA ACTA, 2012, 735 : 23 - 30
  • [47] Development of a Generic Enzyme-Immunoassay for the Detection of Fluoro(quinolone)-Residues in Foodstuffs Based on a Highly Sensitive Monoclonal Antibody
    Acaroz, Ulas
    Dietrich, Richard
    Knauer, Maria
    Maertlbauer, Erwin
    FOOD ANALYTICAL METHODS, 2020, 13 (03) : 780 - 792
  • [48] Development of a Generic Enzyme-Immunoassay for the Detection of Fluoro(quinolone)-Residues in Foodstuffs Based on a Highly Sensitive Monoclonal Antibody
    Ulas Acaroz
    Richard Dietrich
    Maria Knauer
    Erwin Märtlbauer
    Food Analytical Methods, 2020, 13 : 780 - 792
  • [49] The development of a highly specific, sensitive enzyme immunoassay for prostaglandin E1
    Linsky, R
    Buckwalter, J
    Schmidt, N
    Scheuer, B
    Hart, R
    RECENT ADVANCES IN PROSTAGLANDIN, THROMBOXANE, AND LEUKOTRIENE RESEARCH, 1997, 433 : 423 - 426
  • [50] Production of antibodies and development of highly sensitive formats of enzyme immunoassay for saxitoxin analysis
    Micheli, L
    Di Stefano, S
    Moscone, D
    Palleschi, G
    Marini, S
    Coletta, M
    Draisci, R
    Quadri, FD
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) : 678 - 684