Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques

被引:63
|
作者
Iorio, R. [1 ,2 ]
Pagnottelli, M. [1 ,2 ]
Vadala, A. [1 ,2 ]
Giannetti, S. [1 ,2 ]
Di Sette, P. [1 ,2 ]
Papandrea, P. [1 ,2 ]
Conteduca, F. [1 ,2 ]
Ferretti, A. [1 ,2 ]
机构
[1] Univ Roma La Sapienza, S Andrea Hosp, Orthopaed Unit, I-00123 Rome, RM, Italy
[2] Univ Roma La Sapienza, S Andrea Hosp, Kirk Kilgour Sports Injury Ctr, I-00123 Rome, RM, Italy
关键词
Open-wedge high tibial osteotomy; mFTA; Tibial slope; Computer-assisted technique; TERM-FOLLOW-UP; LONG-TERM; VARUS GONARTHROSIS; VALGUS OSTEOTOMY; PATELLAR HEIGHT; SAGITTAL PLANE; CONVENTIONAL TECHNIQUE; EXTERNAL FIXATOR; AXIAL ALIGNMENT; KNEE;
D O I
10.1007/s00167-011-1785-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of our study was to compare clinical and radiological results of two groups of patients treated for medial compartment osteoarthritis of the knee with either conventional or computer-assisted open-wedge high tibial osteotomy (HTO). Goals of surgical treatment were a correction of the mechanical axis between 2A degrees and 6A degrees of valgus and a modification of posterior tibial slope between -2A degrees and +2A degrees. Twenty-four patients (27 knees) affected by varus knee deformity and operated with HTO were prospectively followed-up. They were randomly divided in two groups, A (11 patients, conventional treatment) and B (13 patients, navigated treatment). The American Knee Society Score and the Modified Cincinnati Rating System Questionnaire were used for clinical assessment. All patients were radiologically evaluated with a comparative lower limb weight-bearing digital radiograph, a standard digital anteroposterior, a latero-lateral radiograph of the knee, and a Rosenberg view. Patients were followed-up at a mean of 39 months. Clinical evaluation showed no statistical difference (n.s.) between the two groups. Radiological results showed an 86% reproducibility in achieving a mechanical axis of 182A degrees-186A degrees in group B compared to a 23% in group A (p = 0.0392); furthermore, in group B, we achieved a modification of posterior tibial slope between -2A degrees and +2A degrees in 100% of patients, while in group A, this goal was achieved only in 24% of cases (p = 0.0021). High tibial osteotomy with navigator is more accurate and reproducible in the correction of the deformity compared to standard technique. Therapeutic study, Level II.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [31] Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
    Lee, Sung-Sahn
    Park, Jaesung
    Lee, Dae-Hee
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [32] PRECISION OF NAVIGATED AND CONVENTIONAL OPEN-WEDGE HIGH TIBIAL OSTEOTOMY IN A CADAVER STUDY
    Luetzner, J.
    Gross, A. F.
    Guenther, K. P.
    Kirschner, S.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 (03) : 117 - 120
  • [33] A new technique of autologous bone grafting for open-wedge high tibial osteotomy
    Gong, Yongchao
    Jin, Lin
    Wang, Yanwei
    Liu, Boxu
    Shen, Pengfei
    Zhang, Zhiang
    Yuwen, Peizhi
    Zhao, Kuo
    Ma, Lijie
    Chen, Wei
    Zhang, Yingze
    FRONTIERS IN SURGERY, 2024, 11
  • [34] Closed-wedge high tibial osteotomy is more advantageous to maintain the correction than open-wedge high tibial osteotomy in osteopenic patients
    Song, Sang Jun
    Yoon, Kyoung Ho
    Kim, Kang Il
    Park, Cheol Hee
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (04) : 1563 - 1570
  • [35] Closed-wedge high tibial osteotomy is more advantageous to maintain the correction than open-wedge high tibial osteotomy in osteopenic patients
    Sang Jun Song
    Kyoung Ho Yoon
    Kang Il Kim
    Cheol Hee Park
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1563 - 1570
  • [36] Tranexamic acid is effective for blood management in open-wedge high tibial osteotomy
    Kim, Kang-Il
    Kim, Hwan Jin
    Kim, Gi Beom
    Bae, Seong Hae
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) : 1003 - 1007
  • [37] No correction angle loss with stable plates in open-wedge high tibial osteotomy
    Min Kyu Kim
    Jeong Ku Ha
    Dhong Won Lee
    Sang Wook Nam
    Jin Goo Kim
    Yong Seuk Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1999 - 2006
  • [38] Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
    Lee, Yong Seuk
    Kim, Min Gyu
    Byun, Hae Won
    Kim, Sang Bum
    Kim, Jin Goo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 846 - 851
  • [39] No correction angle loss with stable plates in open-wedge high tibial osteotomy
    Kim, Min Kyu
    Ha, Jeong Ku
    Lee, Dhong Won
    Nam, Sang Wook
    Kim, Jin Goo
    Lee, Yong Seuk
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) : 1999 - 2006
  • [40] Tranexamic Acid Is Beneficial to Patients Undergoing Open-Wedge High Tibial Osteotomy
    Chen, De-Sheng
    Zhu, Jia-Wang
    Wang, Tong-Fu
    Zhu, Bo
    Feng, Cai-Hong
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020