Ultrasensitive peptide-based multiplexed electrochemical biosensor for the simultaneous detection of Listeria monocytogenes and Staphylococcus aureus

被引:59
|
作者
Eissa, Shimaa [1 ]
Zourob, Mohammed [1 ,2 ]
机构
[1] Alfaisal Univ, Dept Chem, Al Zahrawi St,Al Takhassusi Rd, Riyadh 11533, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Zahrawi St, Riyadh 12713, Saudi Arabia
关键词
Multiplexed detection; Square wave voltammetry; Magnetic nanobeads; Biotinylated peptide; Array electrodes; Gold nanoparticles; METHICILLIN-RESISTANT; SALMONELLA-TYPHIMURIUM; SENSITIVE DETECTION; RAPID DETECTION; GRAPHENE OXIDE; IMMUNOSENSOR; APTASENSOR; DIFFERENTIATION; IMMOBILIZATION; FLUORESCENCE;
D O I
10.1007/s00604-020-04423-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical biosensor is reported for simultaneous detection of two of the most common food-borne pathogens: Listeria monocytogenes and Staphylococcus aureus. The biosensor is composed of an array of gold nanoparticles-modified screen-printed carbon electrodes on which magnetic nanoparticles coupled to specific peptides were immobilized via streptavidin-biotin interaction. Taking advantage of the proteolytic activities of the protease enzymes produced from the two bacteria on the specific peptides, the detection was achieved in 1 min. The detection was realized by measuring the percentage increase of the square wave voltammetric peak current at 0.1 V versus a Ag/AgCl reference electrode in ferro/ferricyanide redox couple after incubation with the bacteria protease. The integration of the specificity of the bacterial enzymes towards their peptide substrates with the sensitivity of the electrochemical detection on the sensor array allows the rapid, sensitive and selective quantification of the two bacteria. Outstanding sensitivities were achieved using this biosensor array platform with limit of detection of 9 CFU mL(-1) for Listeria monocytogenes and 3 CFU mL(-1) for Staphylococcus aureus. The multiplexing capability and selectivity of the array voltammetric biosensor were demonstrated by analysing samples of Staphylococcus aureus, Listeria monocytogenes or E. coli and also containing a mixture of two or three bacteria. Using this biosensor, the two bacteria were successfully quantified simultaneously in one step without the need for DNA extraction or amplification techniques. This platform offers promise for rapid, simple and cost-effective simultaneous detection of various bacteria. Graphical abstract
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Simultaneous quantitative analysis of Listeria monocytogenes and Staphylococcus aureus based on antibiotic-introduced lateral flow immunoassay
    Huang, Qiong
    ANALYTICAL METHODS, 2021, 13 (48) : 5866 - 5874
  • [22] Chronopotentiometric sensors for antimicrobial peptide-based biosensing of Staphylococcus aureus
    Zhao, Jiarong
    Ding, Jiawang
    Luan, Feng
    Qin, Wei
    MICROCHIMICA ACTA, 2024, 191 (06)
  • [23] Flow-Through Electrochemical Biosensor for the Detection of Listeria monocytogenes Using Oligonucleotides
    Armstrong, Cheryl M.
    Lee, Joe
    Gehring, Andrew G.
    Capobianco, Joseph A.
    SENSORS, 2021, 21 (11)
  • [24] A Bacteriophage-Based Electrochemical Biosensor for Detection of Methicillin-Resistant Staphylococcus aureus
    Patel, Dhara
    Zhou, Yan
    Ramasamy, Ramaraja P.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [25] Ultrasensitive Electrochemical Biosensor for the Detection of the mecA Gene Sequence in Methicillin Resistant Strains of Staphylococcus aureus Employing Gold Nanoparticles
    Liu, Min
    Xiang, Hua
    Hua, Erhui
    Wang, Li
    Jing, Xiaoying
    Cao, Xianqing
    Sheng, Shangchun
    Xie, Guoming
    ANALYTICAL LETTERS, 2014, 47 (04) : 579 - 591
  • [26] A dual electrochemical/colorimetric magnetic nanoparticle/peptide-based platform for the detection ofStaphylococcus aureus
    Eissa, Shimaa
    Zourob, Mohammed
    ANALYST, 2020, 145 (13) : 4606 - 4614
  • [27] PlcA-based nanofabricated electrochemical DNA biosensor for the detection of Listeria monocytogenes in raw milk samples
    Kritika Saini
    Ankur Kaushal
    Shagun Gupta
    Dinesh Kumar
    3 Biotech, 2020, 10
  • [28] Development of dual polymerase spiral reaction for detection of Listeria monocytogenes and Staphylococcus aureus simultaneously
    Zhang, Moran
    Chen, Hongzhou
    Huang, Jiaming
    Dai, Yongjin
    Liu, Yujuan
    Zhou, Xiyao
    Li, Xiangfei
    Pang, Xinyi
    Sun, Jing
    Lu, Yingjian
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2025, 430
  • [29] Construction of an electrochemical aptasensor based on a covalent organic framework for rapid and ultrasensitive detection of Staphylococcus aureus
    Zhang, Tianzhan
    Wang, Yurou
    Yuan, Rongrong
    Qi, Yanfei
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 428
  • [30] A Distributed MEMS Based Biosensor For Detection Of Staphylococcus Aureus
    Gupta, Siddhant
    Upadhayay, Madhur Deo
    Pal, Srikanta