RETRACTED: Diagnostic accuracy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease (Retracted Article)

被引:25
|
作者
Pelliccia, F. [1 ]
Pasceri, V. [2 ]
Evangelista, A. [1 ,3 ]
Pergolini, A. [1 ,3 ]
Barilla, F. [1 ]
Viceconte, N. [1 ]
Tanzilli, G. [1 ]
Schiariti, M. [1 ]
Greco, C. [1 ,4 ]
Gaudio, C. [1 ,4 ]
机构
[1] Univ Roma La Sapienza, Dept Heart & Great Vessels Attilio Reale, I-00179 Rome, Italy
[2] San Filippo Neri Hosp, Dept Cardiovasc Dis, Rome, Italy
[3] Villa Sandra Hosp, Dept Radiol, Rome, Italy
[4] Eleonora Lorillard Spencer Cenci Fdn, Rome, Italy
来源
关键词
Angiography; Computed tomography; Coronary artery disease; Coronary vessels; Imaging; RADIATION-EXPOSURE; IMAGE QUALITY; PERFORMANCE; VALIDATION; REGRESSION;
D O I
10.1007/s10554-012-0095-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Noninvasive coronary angiography with multislice computed tomography (CT) scanners is feasible with high sensitivity and negative predictive value. The radiation exposure associated with this technique, however, is high and concerns in the widespread use of CT have arisen. We evaluated the diagnostic accuracy of coronary angiography using 320-row CT, which avoids exposure-intensive overscanning and overranging. We prospectively studied 118 unselected consecutive patients with suspected coronary artery disease (CAD) referred for invasive coronary angiography (ICA). All patients had 320-row CT within 1 week of ICA, which, together with quantitative analysis, served as the reference standard. Of the 65 out of 118 patients who were diagnosed as having CAD by ICA, 64 (98 %) were correctly identified at 320-row CT. Noteworthy, 320-row CT correctly detected CAD in 3 patients with atrial fibrillation and ruled out the disease in the other 8 patients. From 151 significant coronary stenoses detected on ICA, 137 (91 %) were correctly identified with 320-row CT. In the per-patient analysis, sensitivity and specificity of 320-row CT were 98 and 91 %, respectively. In the per-vessel analysis, sensitivity and specificity of 320-row CT were 93 and 95 %, respectively. In the per segment analysis, sensitivity and specificity of 320-row CT were 91 and 99 %, respectively. Diameter stenosis determined with the use of CT showed good correlation with ICA (P < 0.001, R = 0.81) without significant underestimation or overestimation (-3.1 +/- A 24.4 %; P = 0.08). Comparison of CT with ICA revealed a significantly smaller effective radiation dose (3.1 +/- A 2.3 vs. 6.5 +/- A 4.2 mSv; P < 0.05) and amount of contrast agent required (99 +/- A 51 vs. 65 +/- A 42 ml, P < 0.05) for 320 row CT. The present study in an unselected population including patients with atrial fibrillation demonstrates that 320-row CT may significantly reduce the radiation dose and amount of contrast agent required compared with ICA while maintaining a very high diagnostic accuracy.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 50 条
  • [31] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [32] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [33] Diagnostic Accuracy of 320-Row Computed Tomography for Characterizing Coronary Atherosclerotic Plaques: Comparison with Intravascular Optical Coherence Tomography
    Ybarra, Luiz F.
    Szarf, Gilberto
    Ishikawa, Walther
    Chamie, Daniel
    Caixeta, Adriano
    Puri, Rishi
    Perin, Marco A.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (05) : 640 - 646
  • [34] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [35] Coronary Computed Tomography Angiography Guided Triage of Patients with Suspected Coronary Artery Disease
    Zhai, Xue
    Gai, Luyue
    Gai, Jingling
    Zhang, Kaiyi
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (07): : 71B - 71B
  • [36] Computed tomography coronary angiography plaque burden in patients with suspected coronary artery disease
    Maffei, Erica
    Seitun, Sara
    Romano, Matteo
    Palumbo, Alessandro A.
    Martini, Chiara
    Tarantini, Giuseppe
    Tedeschi, Carlo
    Weustink, Annick C.
    Mollet, Nico R.
    Arcadi, Teresa
    Salamone, Ignazio
    Blandino, Alfredo
    La Grutta, Ludovico
    Midiri, Massimo
    Cademartiri, Filippo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (12) : 913 - 920
  • [37] RETRACTED: Prognostic Utility of Coronary Computed Tomographic Angiography: A 5-Year Follow-Up in Type 2 Diabetes Patients with Suspected Coronary Artery Disease (Retracted Article)
    Liu, Daliang
    Jia, Huijuan
    Fu, Yucun
    He, Wen
    Ma, Daqing
    JOURNAL OF DIABETES RESEARCH, 2014, 2014
  • [38] REDUCTION OF RADIATION DOSE OF 320-ROW CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY THROUGH PRIOR CORONARY CALCIUM SCANNING
    Dewey, Marc
    Zimmermann, Elke
    Wollenberg, Ulrike
    Rief, Matthias
    Greupner, Johannes
    Hamm, Bernd
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [39] Diagnostic Performance of 64-versus 256-Slice Computed Tomography Coronary Angiography Compared with Conventional Coronary Angiography in Patients with Suspected Coronary Artery Disease
    Chua, Su-Kiat
    Hung, Huei-Fong
    Cheng, Jun-Jack
    Tseng, Min-Tsung
    Law, Wai-Yip
    Kuo, Chu-Jen
    Chiu, Chiung-Zuan
    Chang, Che-Ming
    Lee, Shih-Huang
    Lo, Huey-Ming
    Lin, Sheng-Chang
    Liou, Jer-Young
    Shyu, Kou-Gi
    ACTA CARDIOLOGICA SINICA, 2013, 29 (02) : 151 - 159
  • [40] Possibility of novel non-contrast coronary artery assessment with 320-row computed tomography: promising compatibility with coronary angiography study
    Ide, S.
    Yokoi, K.
    Okayama, K.
    Siegrist, P.
    Mizote, I.
    Kumada, M.
    Kuroda, T.
    Tachibana, K.
    Sumitsuji, S.
    Nanto, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 845 - 846