Effects of rotational speed on the hydrodynamic properties of pharmaceutical antibodies measured by analytical ultracentrifugation sedimentation velocity

被引:5
|
作者
Krayukhina, Elena [1 ]
Uchiyama, Susumu [1 ]
Fukui, Kiichi [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Suita, Osaka 5650871, Japan
关键词
Antibody; Analytical ultracentrifugation; Sedimentation velocity; Frictional ratio; SIZE-EXCLUSION CHROMATOGRAPHY; FIELD-FLOW FRACTIONATION; MOLECULAR-WEIGHT; PROTEIN AGGREGATION; HUMAN-IGG; QUANTITATION; DISTRIBUTIONS; FORMULATION; STRATEGIES; PARTICLES;
D O I
10.1016/j.ejps.2012.06.005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Analytical ultracentrifugation sedimentation velocity (AUC-SV) has recently become one of the most important tools for the measurement of hydrodynamic properties of proteins. Although a number of studies using AUC-SV as applied to pharmaceutical antibodies have been conducted, the effect of rotational speed on molecular properties has not been systematically examined. The present study aimed to elucidate the influence of rotational speed on the hydrodynamic parameters of pharmaceutical antibodies. A monoclonal and a polyclonal antibody were studied by using AUC-SV at 5 different rotor speeds, and the acquired data were analyzed either by using the computer programs SEDFIT or UltraScan. The frictional ratio of the studied antibodies decreased at high rotor speeds, resulting in underestimation of molecular weight. The frictional ratio value of the monoclonal antibody measured at the low rotor speed was consistent with that of human immunoglobulin Cl computed from its three-dimensional structure. The best agreement between the measured molecular weight and the value calculated from the antibody sequence was achieved at the lower rotor speed. Similar to the results obtained using antibodies, AUC-SV analysis of human serum albumin revealed that the frictional ratio and apparent molecular weight behave in a speed-dependent manner. We deduced that the findings were mainly attributable to the hydrostatic pressure in the analytical ultracentrifuge. The current study implies that rotor speed should be carefully considered in antibody studies using AUC-SV. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 50 条
  • [21] Small Volume Analytical Ultracentrifugation of AAV Vectors Based on the Band Sedimentation Velocity Method
    Maruno, Takahiro
    Ishii, Kentaro
    Torisu, Tetsuo
    Uchiyama, Susumu
    MOLECULAR THERAPY, 2023, 31 (04) : 577 - 577
  • [22] Fluorescence Detected Sedimentation Velocity Analytical Ultracentrifugation for Investigating Affinity and Stoichiometry of Protein Interactions
    Zhao, Huaying
    Chaturvedi, Sumit
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 199A - 199A
  • [23] A Bayesian Approach for Quantifying Trace Amounts of Antibody Aggregates by Sedimentation Velocity Analytical Ultracentrifugation
    Brown, Patrick H.
    Balbo, Andrea
    Schuck, Peter
    AAPS JOURNAL, 2008, 10 (03): : 481 - 493
  • [24] Sedimentation Velocity Analytical Ultracentrifugation Analysis of Marketed Rituximab Drug Product Size Distribution
    Sharadrao M. Patil
    John Nguyen
    David A. Keire
    Kang Chen
    Pharmaceutical Research, 2020, 37
  • [25] Sedimentation velocity analytical ultracentrifugation studies of the 14-3-3 protein complexes
    Petrvalska, O.
    Kosek, D.
    Smidova, A.
    Kylarova, S.
    Kalabova, D.
    Obsilova, V.
    Obsil, T.
    FEBS JOURNAL, 2017, 284 : 85 - 86
  • [26] Sedimentation Velocity Analytical Ultracentrifugation Analysis of Marketed Rituximab Drug Product Size Distribution
    Patil, Sharadrao M.
    Nguyen, John
    Keire, David A.
    Chen, Kang
    PHARMACEUTICAL RESEARCH, 2020, 37 (12)
  • [27] Studying Rapidly Reversible Protein-Protein Interactions by Sedimentation Velocity Analytical Ultracentrifugation
    Zhao, Huaying
    Brown, Patrick H.
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 387 - 387
  • [28] Tubulin Heterodimers Reversibly Dissociate with Moderate Kinetics as Demonstrated using Sedimentation Velocity Analytical Ultracentrifugation
    Montecinos-Franjola, Felipe
    Sackett, Dan L.
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2014, 106 (02) : 351A - 351A
  • [29] A new adaptive grid-size algorithm for the simulation of sedimentation velocity profiles in analytical ultracentrifugation
    Brown, Patrick H.
    Schuck, Peter
    COMPUTER PHYSICS COMMUNICATIONS, 2008, 178 (02) : 105 - 120
  • [30] An optical alignment system improves precision of soluble aggregate quantitation by sedimentation velocity analytical ultracentrifugation
    Doyle, Brandon L.
    Budyak, Ivan L.
    Rauk, Adam P.
    Weiss, William F.
    ANALYTICAL BIOCHEMISTRY, 2017, 531 : 16 - 19