FULL-COVERAGE FILM COOLING: HEAT TRANSFER COEFFICIENTS AND FILM EFFECTIVENESS FOR A SPARSE HOLE ARRAY AT DIFFERENT BLOWING RATIOS AND CONTRACTION RATIOS

被引:0
|
作者
Ligrani, Phil [1 ]
Goodrog, Matt [1 ]
Fox, Michael D. [2 ]
Moon, Hee-Koo [2 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford, England
[2] Solar Turbines Inc, San Diego, CA USA
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3B | 2013年
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present experimental investigation considers a full coverage film cooling arrangement with differrent streamwise static pressure gradients. The film cooling holes in adjacent streamwise rows are staggered with respect to each other, with sharp edges, and streamwise inclination angles of 20 degrees with respect to the liner surface. Data are provided for turbulent film cooling, contraction ratios of 1 and 4, blowing ratios (at the test section entrance) of 2.0, 5.0, and 10.0, coolant Reynolds numbers of 12,000, freestream temperatures from 75 degrees C to 115 degrees C, a film hole diameter of 7 mm, and density ratios from 1.15 to 1.25. Non-dimensional streamwise and spanwise film cooling hole spacings, X/D and Y/D, are 18, and 5, respectively. Data illustrating the effects of contraction ratio, blowing ratio, and streamwise location on local, line-averaged and spatially-averaged adiabatic film effectiveness data, and on local, line-averaged and spatially-averaged heat transfer coefficient data are presented. Varying blowing ratio values are utilized along the length of the contraction passage, which contains the cooling hole arrangement, when contraction ratio is 4. Dependence on blowing ratio indicates important influences of coolant concentration and distribution. For example, line-averaged and spatially-averaged adiabatic effectiveness data show vastly different changes with blowing ratio BR for the configurations with contraction ratios of 1 and 4. These changes from acceleration are thus mostly due to different blowing ratio distributions along the test section. In particular, much larger effectiveness alterations are present as BR changes from 2.0 to 10.0, when significant acceleration is present and Cr=4 (in comparison with the Cr=1 data). When BR=10.0, much smaller changes due to different contract ratios are present. This is because coolant distributions along the test surfaces are so abundant that magnitudes of streamwise acceleration (and different streamwise variations of blowing ratio) have little effect on near-wall film concentration distributions, or on variations of film cooling effectiveness.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] TURBINE BLADE TIP FILM-COOLING AND HEAT TRANSFER MEASUREMENTS AT HIGH BLOWING RATIOS
    Narzary, Diganta
    Liu, Kevin
    Han, Je-Chin
    Mhetras, Shantanu
    Landis, Kenneth
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5B, 2014,
  • [22] EFFECTS OF DENSITY AND BLOWING RATIOS ON THE TURBULENT STRUCTURE AND EFFECTIVENESS OF FILM-COOLING
    Stratton, Zachary T.
    Shih, Tom I-R
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2018, VOL 5A, 2018,
  • [23] AN EXPERIMENTAL INVESTIGATION OF FULL-COVERAGE FILM COOLING EFFECTIVENESS AND HEAT TRANSFER COEFFICIENT OF A TURBINE GUIDE VANE IN A LINEAR TRANSONIC CASCADE
    Fu, Zhong-yi
    Zhu, Hui-ren
    Liu, Cun-liang
    Liu, Cong
    Li, Zheng
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 5C, 2016,
  • [24] FULL-COVERAGE FILM COOLING .2. HEAT-TRANSFER DATA AND NUMERICAL-SIMULATION
    CRAWFORD, ME
    KAYS, WM
    MOFFAT, RJ
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1980, 102 (04): : 1006 - 1012
  • [25] Experimental Evaluation of Large Spacing Compound Angle Full-Coverage Film Cooling Arrays: Adiabatic Film Cooling Effectiveness
    Natsui, Greg
    Claretti, Roberto
    Ricklick, Mark A.
    Kapat, Jayanta S.
    Crawford, Michael E.
    Brown, Glenn
    Landis, Kenneth
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2016, 138 (07):
  • [26] Film cooling in the trailing edge cutback with different land shapes and blowing ratios
    Du, Wei
    Luo, Lei
    Wang, Songtao
    Sunden, Bengt
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 125
  • [27] Experimental investigation of adiabatic effectiveness of inclined multihole wall full-coverage film cooling with heat-mass transfer analogy method
    Fang, Ren
    Li, Bin
    Lin, Yuzhen
    Liu, Gao'en
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 13 (01): : 65 - 68
  • [28] EFFECT OF BLOWING RATIO ON THE FILM COOLING EFFECTIVENESS ON A FLAT PLATE WITH VARIOUS BLOCKAGE RATIOS
    Aly, Omar Deyab
    Wright, Lesley M.
    Hassan, Ibrahim
    PROCEEDINGS OF ASME 2024 HEAT TRANSFER SUMMER CONFERENCE, HT 2024, 2024,
  • [29] FULL-COVERAGE FILM COOLING .1. COMPARISON OF HEAT-TRANSFER DATA FOR 3 INJECTION ANGLES
    CRAWFORD, ME
    KAYS, WM
    MOFFAT, RJ
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1980, 102 (04): : 1000 - 1005
  • [30] Full-coverage film cooling on curved walls, part 3, cooling effectiveness on concave and convex walls
    Kasagi, Nobuhide
    Hirata, Masaru
    Ikeyama, Masataka
    Makino, Masaki
    Kumada, Masaya
    Heat Transfer - Japanese Research, 1989, 18 (02): : 28 - 42