Discussion on the Feasibility of Deep Peak Regulation for Ultra-Supercritical Circulating Fluidized Bed Boiler

被引:8
|
作者
Xin, Shengwei [1 ]
Wang, Hu [1 ]
Li, Jianbo [2 ]
Wang, Gang [3 ]
Wang, Quanhai [2 ]
Cao, Peiqing [1 ]
Zhang, Peng [1 ]
Lu, Xiaofeng [2 ]
机构
[1] CHN Energy Grp CFB Technol R&D Ctr, Xian 710065, Peoples R China
[2] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
[3] Harbin Boiler Co Ltd, Harbin 150046, Peoples R China
关键词
boiler load; deep peak regulation; stable combustion; ultra-SC-CFB;
D O I
10.3390/en15207720
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to meet the flexibility operation needs of coal-fired units under the goal of carbon peak and carbon neutralization, it is imperative for circulating fluidized bed (CFB) units to participate in deep peak regulation. By systematically summarizing deep peak regulation operation practice of existing SC and subcritical-parameter-levels CFB units, the feasibility of deep peak regulation technology of an ultra-supercritical (USC) CFB unit under development and being built is analyzed and demonstrated; meanwhile, the deep peak regulation capacity of the boiler is also predicted. The results show that by analyzing the structural characteristics and design performance of the USC-CFB boiler, for technical problems such as stable combustion under low load, hydrodynamic safety, denitration performance under wide load, and rapid boiler load change rate existing in deep peak regulation, technical measures were implemented by selecting advanced boiler furnace type, adopting good design technology of the secondary rising water wall and uniformity design of bed temperature and bed pressure, strengthening the reducing atmosphere inside the furnace, improving the performance of wear-resistant refractory materials, quickly controlling the furnace bed material stock under variable load, optimizing the control strategy of CFB unit, and so on. The boiler achieved good operation characteristics and good deep peak regulation performance, and the pollutant emissions can steadily achieve ultra-low emission standards. When the USC-CFB unit participates in deep peak regulation, the minimum stable combustion load of the boiler can reach 20 similar to 30% BMCR, and a boiler load change rate under 30% BMCR or above could reach 1.5 similar to 2% BMCR/min, while that below 30% BMCR could reach 1% BMCR/min. The research results can provide references for the deep peak regulation of in-service supercritical (SC) CFB units and design optimization of similar USC-CFB units.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Computational Analysis on Thermal-hydraulic Characteristics and Flow Instability of a 660MW Ultra-supercritical Circulating Fluidized Bed Boiler
    Dong L.
    Xin Y.
    Li J.
    Yang D.
    Jiang X.
    Wang G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (05): : 1545 - 1553
  • [22] Hydrodynamic Characteristics of Deep Peak Shaving and Calculation of Water Wall Thermal Deviation of Supercritical Circulating Fluidized Bed Boiler
    Zhang, Xirong
    Song, Yuanyuan
    Zhou, Yanjun
    Lyu, Junfu
    Huang, Zhong
    Yang, Dong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (15): : 6047 - 6056
  • [23] Experimental and Theoretical Study on CHF of a Ultra-Supercritical Circulating Fluidized Bed Boiler Water-Wall Tube at near-Critical Pressures
    WANG Wenyu
    MA Zhan
    QING Hao
    NIE Chao
    YANG Haoyu
    BI Lingfeng
    YANG Dong
    PAN Wenxiao
    Journal of Thermal Science, 2023, 32 (01) : 166 - 182
  • [24] Experimental and Theoretical Study on CHF of a Ultra-Supercritical Circulating Fluidized Bed Boiler Water-Wall Tube at Near-Critical Pressures
    Wenyu Wang
    Zhan Ma
    Hao Qing
    Chao Nie
    Haoyu Yang
    Lingfeng Bi
    Dong Yang
    Wenxiao Pan
    Journal of Thermal Science, 2023, 32 : 166 - 182
  • [25] Experimental and Theoretical Study on CHF of a Ultra-Supercritical Circulating Fluidized Bed Boiler Water-Wall Tube at Near-Critical Pressures
    Wang Wenyu
    Ma Zhan
    Qing Hao
    Nie Chao
    Yang Haoyu
    Bi Lingfeng
    Yang Dong
    Pan Wenxiao
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (01) : 166 - 182
  • [26] Calculation and Analysis of Flow Instability Characteristics in Water Wall of Supercritical Circulating Fluidized Bed Boiler During Deep Peak Shaving
    Li, Weiteng
    Guo, Zerui
    Han, Lei
    Yang, Dong
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2025, 59 (01): : 68 - 77
  • [27] Deep Desulphurization and DeNOX in Circulating Fluidized Bed Boiler
    Zeng Tinghua
    Electricity, 2011, 22 (05) : 46 - 49
  • [28] Online tracking simulation system for a 660 MW Ultra-Supercritical circulating fluidized bed boiler based on mechanistic models and artificial neural network models
    Yang, Chen
    Sun, Li
    Wang, Xiaosheng
    Zhang, Zonglong
    APPLIED THERMAL ENGINEERING, 2025, 270
  • [29] Design of 600MW supercritical circulating fluidized bed boiler
    Dongfang boiler Co. Ltd., Zigong 643001, China
    Dongli Gongcheng, 2008, 5 (701-706):
  • [30] Research on energy distribution characteristics of supercritical circulating fluidized bed boiler
    Xie, Guowei
    Hu, Changhua
    Zhang, Peng
    Gu, Congyang
    Xin, Shengwei
    Wang, Hu
    Wu, Wanzhu
    Du, Jiajun
    THIRD INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2019, 227