Effective densities of atmospheric aerosols in various locations of the Los Angeles Basin were determined by a DMA-APM technique. Effective density was calculated by comparing voltage distributions of sampled atmospheric aerosols with PSL particles of known density. The five sites chosen for field experiments were: (1) Interstate-710 Freeway, impacted by heavy-duty diesel vehicles; (2) State Route CA-110, open only to gasoline vehicles; (3) Riverside, a receptor site known for secondary particle formation; (4) University of Southern California, a typical urban and industrial environment; (5) Coast for marine aerosol. The size range selected for this study was from 50 nm to 414 nm. While 50 nm particles exhibited a single effective density multiple effective densities were measured for each of the other particle sizes as significant fractions of these particles are transported from background sources. Regardless of location, 322-414 nm particle effective densities were considerably lower than unity. The lowest effective densities (approximate to 0.1 g cm(-3)) were reported for I-710, confirming that diesel combustion aerosols are rich in chain agglomerates with large void spaces. Riverside exhibited high effective densities (approximate to 1.2-1.5 g cm(-3)) for 50-202 nm particles, which we hypothesize is due to transformations that occur during advection from Los Angeles. Measurements of diurnal variation of effective density at Riverside support this hypothesis. Overall, our results suggest that effective density declines as the particle mobility diameter increases irrespective of location. Fractal dimensions calculated from average effective densities were lowest for I-710 (D-f = 2.41) and CA-110 (D-f = 2.54) aerosols, presumably due to the influence of vehicular combustion emission on these sites. By contrast, average fractal dimensions at USC, Riverside and Coast were found to be 2.79, 2.83, and 2.92, respectively. High fractal dimensions at these sites may be the effects of aging, moisture absorption and/or organic vapor condensation on the particles, which fills void space and makes particles more spherical.
引用
收藏
页码:709 / 723
页数:15
相关论文
共 50 条
  • [31] COMPARISON AND COMBINATION OF AEROSOL-SIZE DISTRIBUTIONS MEASURED WITH A LOW-PRESSURE IMPACTOR, DIFFERENTIAL MOBILITY PARTICLE SIZER, ELECTRICAL AEROSOL ANALYZER, AND AERODYNAMIC PARTICLE SIZER
    PETERS, TM
    CHEIN, HM
    LUNDGREN, DA
    KEADY, PB
    AEROSOL SCIENCE AND TECHNOLOGY, 1993, 19 (03) : 396 - 405
  • [32] Measurement of Aerosol Particle Charge and Size Distributions by Laser Particle Size Analyzer
    Kashcheev, V. A.
    Poluektov, P. P.
    Semykin, A. H.
    Czitrovszky, A.
    Yani, P.
    LASER PHYSICS, 1992, 2 (04) : 613 - 615
  • [33] New method for particle mass classification - the Couette centrifugal particle mass analyzer
    Olfert, JS
    Collings, N
    JOURNAL OF AEROSOL SCIENCE, 2005, 36 (11) : 1338 - 1352
  • [34] Determination of arbitrary moments of aerosol size distributions from measurements with a differential mobility analyzer
    Natl Research Lab of Metrology, Ibaraki, Japan
    J Aerosol Sci, Suppl. 1 (S369-S370):
  • [35] Determination of arbitrary moments of aerosol size distributions from measurements with a differential mobility analyzer
    Ehara, K
    Mulholland, GW
    Hagwood, RC
    AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (05) : 434 - 452
  • [36] Aqueous film formation on irregularly shaped inorganic nanoparticles before deliquescence, as revealed by a hygroscopic differential mobility analyzer-Aerosol particle mass system
    Hsiao, Ta-Chih
    Young, Li-Hao
    Tai, Yu-Chun
    Chen, Ke-Ching
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (06) : 568 - 577
  • [37] A miniature cylindrical differential mobility analyzer for sub-3 nm particle sizing
    Cai, Runlong
    Chen, Da-Ren
    Hao, Jiming
    Jiang, Jingkun
    JOURNAL OF AEROSOL SCIENCE, 2017, 106 : 111 - 119
  • [38] LOSS OF ULTRAFINE AEROSOL-PARTICLES IN DIFFERENTIAL MOBILITY ANALYZER
    KOUSAKA, Y
    OKUYAMA, K
    HAYASHI, K
    JOURNAL OF AEROSOL SCIENCE, 1984, 15 (03) : 375 - 376
  • [39] Measurement of aerosol effective density by single particle mass spectrometry
    ZHANG GuoHua
    BI XinHui
    HAN BingXue
    QIU Ning
    DAI ShouHui
    WANG XinMing
    SHENG GuoYing
    FU JiaMo
    Science China(Earth Sciences), 2016, 59 (02) : 320 - 327
  • [40] Measurement of aerosol effective density by single particle mass spectrometry
    Zhang GuoHua
    Bi XinHui
    Han BingXue
    Qiu Ning
    Dai ShouHui
    Wang XinMing
    Sheng GuoYing
    Fu JiaMo
    SCIENCE CHINA-EARTH SCIENCES, 2016, 59 (02) : 320 - 327