摘要
As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for the rational comparison of clinical results from different institutions. In this paper we report development of a reference suite of computational test problems for NCT dosimetry and discuss common issues encountered in these calculations to facilitate quantitative evaluations and comparisons of NCT treatment planning codes. Specifically, detailed depth-kerma rate curves were calculated using the Monte Carlo radiation transport code MCNP4B for four different representations of the modified Snyder head phantom, an analytic, multishell, ellipsoidal model, and voxel representations of this model with cubic voxel sizes of 16, 8, and 4 mm. Monoenergetic and monodirectional beams of 0.0253 eV, 1, 2, 10, 100, and 1000 keV neutrons, and 0.2, 0.5, 1, 2, 5, and 10 MeV photons were individually simulated to calculate kerma rates to a statistical uncertainty of <1% (1 std. dev.) in the center of the head model. In addition, a "generic" epithermal neutron beam with a broad neutron spectrum, similar to epithermal beams currently used or proposed for NCT clinical trials, was computed for all models. The thermal neutron, fast neutron, and photon kerma. rates calculated with the 4 and 8 mm. voxel models were within 2% and 4%, respectively, of those calculated for the analytical model. The 16 mm voxel model produced unacceptably large discrepancies for all dose components. The effects from different kerma data sets and tissue compositions were evaluated. Updating the kerma data from ICRU 46 to ICRU 63 data produced less than 2% difference in kerma rate profiles. The depth-dose profile data, Monte Carlo code input, kerma factors, and model construction files are available electronically to aid in verifying new and existing NCT treatment planning codes. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 50 条
  • [11] Fricke gel dosimetry in boron neutron capture therapy
    Gambarini, G
    Birattari, C
    Colombi, C
    Pirola, L
    Rosi, G
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 419 - 422
  • [12] A comparison of the COG and MCNP codes in computational neutron capture therapy modeling, part I: Boron neutron capture therapy models
    Culbertson, CN
    Wangerin, K
    Ghandourah, E
    Jevremovic, T
    HEALTH PHYSICS, 2005, 89 (02): : 127 - 134
  • [13] ANALYTICAL MODELING FOR NEUTRON-CAPTURE THERAPY
    WHEELER, FJ
    GRIEBENOW, ML
    WESSOL, DE
    NIGG, DW
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 186 - 188
  • [14] Epithermal neutron beam dosimetry with thermoluminescence dosemeters for boron neutron capture therapy
    Aschan, C
    Toivonen, M
    Savolainen, S
    Seppälä, T
    Auterinen, I
    RADIATION PROTECTION DOSIMETRY, 1999, 81 (01) : 47 - 56
  • [15] Dosimetry and spectrometry at accelerator based neutron source for boron neutron capture therapy
    Bayanov, B.
    Burdakov, A.
    Kuznetsov, A.
    Makarov, A.
    Sinitskii, S.
    Sulyaev, Yu.
    Taskaev, S.
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1462 - 1464
  • [16] Neutron dosimetry on phantom model of pancreatic cancer for boron neutron capture therapy
    Yanagie, H.
    Sakurai, Y.
    Ogura, K.
    Kobayashi, T.
    Furuya, Y.
    Sugiyama, H.
    Hisa, T.
    Ishikawa, M.
    Amemiya, K.
    Takahashi, H.
    Kobayashi, H.
    Tago, M.
    Masunaga, S.
    Ono, K.
    Nakagawa, K.
    Nakzawa, M.
    Eriguchi, M.
    KURRI Progress Report, 2003,
  • [17] Neutron activation and dosimetry studies for a clinical facility of Boron Neutron Capture Therapy
    Magni, C.
    Ferrarini, M.
    Postuma, I.
    Protti, N.
    Fatemi, S.
    Gong, C.
    Anselmi-Tamburini, U.
    Vercesi, V.
    Battistoni, G.
    Bortolussi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2021, 44 (4-5):
  • [18] Computational dosimetry and treatment planning for Boron Neutron Capture Therapy
    David W. Nigg
    Floyd J. Wheeler
    Daniel E. Wessol
    Jacek Capala
    Manjeet Chadha
    Journal of Neuro-Oncology, 1997, 33 : 93 - 103
  • [19] Computational dosimetry and treatment planning considerations for neutron capture therapy
    Nigg, DW
    JOURNAL OF NEURO-ONCOLOGY, 2003, 62 (01) : 75 - 86
  • [20] Computational Dosimetry and Treatment Planning Considerations for Neutron Capture Therapy
    David W. Nigg
    Journal of Neuro-Oncology, 2003, 62 (1) : 75 - 86