Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models

被引:124
|
作者
Goorley, JT [1 ]
Kiger, WS
Zamenhof, RG
机构
[1] MIT, Nucl Reactor Lab, Cambridge, MA 02139 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiat Oncol, Boston, MA 02115 USA
关键词
D O I
10.1118/1.1428758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for the rational comparison of clinical results from different institutions. In this paper we report development of a reference suite of computational test problems for NCT dosimetry and discuss common issues encountered in these calculations to facilitate quantitative evaluations and comparisons of NCT treatment planning codes. Specifically, detailed depth-kerma rate curves were calculated using the Monte Carlo radiation transport code MCNP4B for four different representations of the modified Snyder head phantom, an analytic, multishell, ellipsoidal model, and voxel representations of this model with cubic voxel sizes of 16, 8, and 4 mm. Monoenergetic and monodirectional beams of 0.0253 eV, 1, 2, 10, 100, and 1000 keV neutrons, and 0.2, 0.5, 1, 2, 5, and 10 MeV photons were individually simulated to calculate kerma rates to a statistical uncertainty of <1% (1 std. dev.) in the center of the head model. In addition, a "generic" epithermal neutron beam with a broad neutron spectrum, similar to epithermal beams currently used or proposed for NCT clinical trials, was computed for all models. The thermal neutron, fast neutron, and photon kerma. rates calculated with the 4 and 8 mm. voxel models were within 2% and 4%, respectively, of those calculated for the analytical model. The 16 mm voxel model produced unacceptably large discrepancies for all dose components. The effects from different kerma data sets and tissue compositions were evaluated. Updating the kerma data from ICRU 46 to ICRU 63 data produced less than 2% difference in kerma rate profiles. The depth-dose profile data, Monte Carlo code input, kerma factors, and model construction files are available electronically to aid in verifying new and existing NCT treatment planning codes. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:145 / 156
页数:12
相关论文
共 50 条
  • [1] Comparison of Snyder head phantom models used for Neutron Capture Therapy benchmark Monte Carlo Dosimetry calculations
    Goorley, T
    Kiger, WS
    Zamenhof, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 797 - 802
  • [2] Reference dosimetry at the neutron capture therapy facility at Studsvik
    af Rosenschöld, PMM
    Giusti, V
    Ceberg, CP
    Capala, J
    Sköld, K
    Persson, BRR
    MEDICAL PHYSICS, 2003, 30 (07) : 1569 - 1579
  • [3] Phantoms for neutron capture therapy dosimetry
    Harling, OK
    Rogus, RD
    Redmond, EL
    Roberts, KA
    Moulin, DJ
    Yam, CS
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 511 - 516
  • [4] Clinical dosimetry of an epithermal neutron beam for neutron capture therapy: Dose distributions under reference conditions
    Raaijmakers, CPJ
    Konijnenberg, MW
    Mijnheer, BJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (04): : 941 - 951
  • [5] Dosimetry for gadolinium neutron capture therapy (GdNCT)
    Enger, Shirin A.
    Giusti, Valerio
    Fortin, Marc-Andre
    Lundqvist, Hans
    af Rosenschold, Per Munck
    RADIATION MEASUREMENTS, 2013, 59 : 233 - 240
  • [6] NEUTRON SPECTROMETRY AND DOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY
    PERKS, CA
    GIBSON, JAB
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 425 - 428
  • [7] Reference dosimetry for fast neutron and proton therapy
    Jones, DTL
    RADIOCHIMICA ACTA, 2001, 89 (4-5) : 279 - 287
  • [8] Reference dosimetry for fast neutron and proton therapy
    Jones, DTL
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 1588 - 1591
  • [9] Dosimetry and treatment planning for boron neutron capture therapy
    Raaijmakers, CPJ
    MEDICAL PHYSICS, 1998, 25 (02) : 255 - 255
  • [10] Fricke gel dosimetry in boron neutron capture therapy
    Gambarini, G
    Birattari, C
    Colombi, C
    Pirola, L
    Rosi, G
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A419 - A422