Dynamic Changes in Anterior Segment Morphology during the Valsalva Maneuver Assessed with Ultrasound Biomicroscopy

被引:17
|
作者
Wang, Bing-Song [3 ]
Xiao, Lin [3 ]
Liu, Jing [3 ]
Dong, Ning [3 ]
Aung, Tin [1 ,2 ,4 ]
机构
[1] Singapore Natl Eye Ctr, Glaucoma Serv, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Capital Univ Med Sci, Beijing Shijitan Hosp, Dept Ophthalmol, Beijing, Peoples R China
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
关键词
ANGLE-CLOSURE GLAUCOMA; INTRAOCULAR-PRESSURE; CHINESE; ASSOCIATION; PREVALENCE;
D O I
10.1167/iovs.12-10497
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We evaluated dynamic changes in anterior segment morphology during the Valsalva maneuver with ultrasound biomicroscopy (UBM). METHODS. For this prospective observational study, a group of patients with narrow angles and a group of normal subjects were recruited. The anterior segment of subjects was imaged and analyzed quantitatively using UBM before and during the Valsalva maneuver. Changes in anterior segment parameters from baseline and during the Valsalva maneuver, and the differences in parameters between the narrow angle and control groups were analyzed. RESULTS. Of 151 subjects recruited for the study, 68 (45.0%) were men and 83 (54.9%) had narrow angles. For the overall group, during Valsalva maneuver, the subjects' central anterior chamber depth (ACD) became shallower (from 2.286-2.262 mm, P < 0.001), and the anterior chamber angle became narrower (from 14.673-13.370 degrees, P = 0.004), the angle opening distance became smaller (from 0.158-0.140 mm, P 0.014), and the peripheral iris thickness became thicker (from 0.494-0.508 mm, P = 0.041), while the central iris thickness did not change. Compared to normal controls, narrow angle subjects had shallower ACD and thicker iris at baseline, but there was no significant difference between the 2 groups in dynamic changes in the anterior segment after the Valsalva maneuver. CONCLUSIONS. The Valsalva maneuver, performed frequently in daily activities, can lead to significant narrowing of the angles in subjects with open and narrow angles. This factor may be important in eyes at risk for angle closure glaucoma. (Invest Ophthalmol Vis Sci. 2012; 53: 7286-7289) DOI: 10.1167/iovs.12-10497
引用
收藏
页码:7286 / 7289
页数:4
相关论文
共 50 条
  • [41] The use of ultrasound biomicroscopy in the evaluation of anterior segment tumors and simulating conditions
    Guenduez, Kaan
    Hosal, Banu M.
    Zilelioglu, Gueler
    Guenalp, Ilhan
    OPHTHALMOLOGICA, 2007, 221 (05) : 305 - 312
  • [42] Longitudinal study of anterior segment inflammation by ultrasound biomicroscopy in patients with acute anterior uveitis
    Yang Peizeng
    Meng Qianli
    Huang Xiangkun
    Zhou Hongyan
    Wang Li
    Kijlstra, Aize
    ACTA OPHTHALMOLOGICA, 2009, 87 (02) : 211 - 215
  • [43] Clinical 3D Imaging of the Anterior Segment With Ultrasound Biomicroscopy
    Helms, Richard W.
    Minhaz, Ahmed Tahseen
    Wilson, David L.
    Orge, Faruk H.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (03):
  • [44] Ultrasound Biomicroscopy of Anterior Segment Accommodative Changes with Posterior Chamber Phakic Intraocular Lens in High Myopia
    Du, Chixin
    Wang, Jianhua
    Wang, Xiaoyu
    Dong, Ying
    Gu, Yangshun
    Shen, Ye
    OPHTHALMOLOGY, 2012, 119 (01) : 99 - 105
  • [45] Imaging the Canaliculops With Ultrasound Biomicroscopy and Anterior Segment Ocular Coherence Tomography
    Singh, Swati
    Ali, Mohammad Javed
    Peguda, Hari Kumar
    Naik, Milind N.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : E143 - E144
  • [46] Findings in the anterior segment on ultrasound biomicroscopy in Maroteaux-Lamy syndrome
    Casanova, FHC
    Adan, CBD
    Allemann, N
    de Freitas, D
    CORNEA, 2001, 20 (03) : 333 - 338
  • [47] Morphologic changes in the anterior segment using ultrasound biomicroscopy after cataract surgery and intraocular lens implantation
    Unsal, Erkan
    Eltutar, Kadir
    Muftuoglu, Ilkay K.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (01) : 31 - 38
  • [48] Evaluation of Changes in Anterior Segment Configuration by Ultrasound Biomicroscopy after Phacoemulsification and Foldable Intraocular Lens Implantation
    Salcan, Ilhami
    Aykan, Umit
    Yilmaz, Burhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (04): : 200 - 206
  • [49] Anterior Segment Imaging: Optical Coherence Tomography Versus Ultrasound Biomicroscopy
    Garcia, Julian P. S., Jr.
    Rosen, Richard B.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (06) : 476 - 484
  • [50] Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases
    Bianciotto, Carlos
    Shields, Carol L.
    Guzman, Juan M.
    Romanelli-Gobbi, Massi
    Mazzuca, Douglas, Jr.
    Green, W. Ross
    Shields, Jerry A.
    OPHTHALMOLOGY, 2011, 118 (07) : 1297 - 1302