A study of impurities in some CdS/CdTe photovoltaic cells prepared by wet-chemical methods using secondary ion mass spectrometry and X-ray photoelectron spectroscopy

被引:14
|
作者
Boyle, DS
Hearne, S
Johnson, DR
O'Brien, P
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem, London SW7 2AZ, England
[2] Natl Univ Ireland Univ Coll Cork, Natl Microelect Res Ctr, Cork, Ireland
[3] BP Solar Ltd, Sunbury On Thames TW16 7DX, Middx, England
关键词
D O I
10.1039/a904661e
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Quantitative Secondary Ion Mass Spectrometry has been used to determine the elemental profiles and concentrations of isotopes C-12, O-16, S-34 and Cl-35 within n-CdS/p-CdTe thin film photovoltaic cells. Chemical Bath Deposition (CBD) was used to deposit the CdS window layers. The annealing process induces the formation of a chloride-rich surface layer on CdS as evidenced from X-ray photoelectron spectroscopy measurements. The carbon impurity in heterostructures appears to influence the chloride-promoted recrystallisation of CdTe. High concentrations of O-16, of the order 10(20)-10(21) atoms cm(-3) throughout the cells, are consistent with the formation of oxide material in the post-deposition thermal processing. Isotopic profiles for C-12, S-34 and Cl-35 have similar maxima (approximate to 10(19) atoms cm(-3)) but concentrate at the CdS-CdTe interface. The relatively high tolerance to high concentrations of impurities in our cells suggests that wet chemical methods may have great potential in the fabrication of large area/low cost devices.
引用
收藏
页码:2879 / 2884
页数:6
相关论文
共 50 条
  • [21] Characterization of hydrogenated graphite powder by X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry
    Xie, Wenjing
    Ng, Kai Mo
    Weng, Lu-Tao
    Chan, Chi-Ming
    RSC ADVANCES, 2016, 6 (84): : 80649 - 80654
  • [23] Study of Asphaltene Adsorption on Kaolinite by X-ray Photoelectron Spectroscopy and Time-of-Flight Secondary Ion Mass Spectroscopy
    Wang, Shanshan
    Liu, Qi
    Tan, Xiaoli
    Xu, Chunming
    Gray, Murray R.
    ENERGY & FUELS, 2013, 27 (05) : 2465 - 2473
  • [24] Characterization of Composition C4 Explosives using Time-of-Flight Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy
    Mahoney, Christine M.
    Fahey, Albert J.
    Steffens, Kristen L.
    Benner, Bruce A., Jr.
    ANALYTICAL CHEMISTRY, 2010, 82 (17) : 7237 - 7248
  • [25] Surface characterization of lipid/chitosan nanoparticles assemblies, using X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry
    Grenha, Ana
    Seijo, Begna
    Serra, Carmen
    Remunan-Lopez, Carmen
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (01) : 358 - 365
  • [26] Combined use of atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectrometry for cell surface analysis
    Dague, Etienne
    Delcorte, Arnaud
    Latge, Jean-Paul
    Dufrene, Yves F.
    LANGMUIR, 2008, 24 (07) : 2955 - 2959
  • [27] SURFACE-ANALYSIS OF WOOL BY X-RAY PHOTOELECTRON-SPECTROSCOPY AND STATIC SECONDARY-ION MASS-SPECTROMETRY
    WARD, RJ
    WILLIS, HA
    GEORGE, GA
    GUISE, GB
    DENNING, RJ
    EVANS, DJ
    SHORT, RD
    TEXTILE RESEARCH JOURNAL, 1993, 63 (06) : 362 - 368
  • [28] Surface functionalization of PEEK films studied by time-of-flight secondary ion mass spectrometry and x-ray photoelectron spectroscopy
    Henneuse-Boxus, C
    Poleunis, C
    De Ro, A
    Adriaensen, Y
    Bertrand, P
    Marchand-Brynaert, J
    SURFACE AND INTERFACE ANALYSIS, 1999, 27 (03) : 142 - 152
  • [29] Characterization of insulin adsorption in the presence of albumin by time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy
    Henry, M.
    Dupont-Gillain, C.
    Bertrand, P.
    LANGMUIR, 2008, 24 (02) : 458 - 464
  • [30] Surface functionalization of PEEK films studied by time-of-flight secondary ion mass spectrometry and x-ray photoelectron spectroscopy
    Lab. de Chim. Organique de Synt., Univ. Cathol. Louvain Bat. Lavoisier, place Louis Pasteur 1, B-1348 Louvain-la-Neuve, Belgium
    不详
    Surf Interface Anal, 3 (142-152):