In conventional X-ray computed tomography (CT), X-rays are measured as electric current. Materials inside a subject are described by the linear attenuation coefficients averaged by the energy spectrum of the X-rays. A CT image cannot distinguish materials such as iodine and calcium, because the linear attenuation coefficient is not inherent to a material, but the product of X-ray mass attenuation coefficient and the density of the material. Materials such as iodine and calcium can be distinguished using an energy-resolved CT technique, with a current-mode detector system, using segment detectors aligned in the direction of X-ray incidence: the energy-resolved CT images are reconstructed by the X-rays with the energy of interest, by unfolding electric currents measured by the segment detectors. (C) 2014 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 50 条
  • [31] A Current-Mode Detector for Unfolding X-ray Energy Distribution
    Kanno, Ikuo
    Imamura, Ryo
    Mikami, Kenta
    Uesaka, Akio
    Hashimoto, Makoto
    Ohtaka, Masahiko
    Ara, Kuniaki
    Nomiya, Seiichiro
    Onabe, Hideaki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, 45 (11) : 1165 - 1170
  • [32] ASPECTS OF SEMICONDUCTOR CURRENT MODE DETECTORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GLASOW, PA
    CONRAD, B
    KILLIG, K
    LICHTENBERG, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 563 - 571
  • [33] Two-dimensional "transXend" detector for third-generation energy-resolved computed tomography
    Kanno, Ikuo
    Yamashita, Yoshiki
    Kanai, Eri
    Ogawa, Tsuyoshi
    Shinsho, Kiyomitsu
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2016, 53 (02) : 258 - 262
  • [34] Dual-energy X-ray computed tomography system using an LSO-MPPC detector
    Sato, Eiichi
    Oda, Yasuyuki
    Yamaguchi, Satoshi
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Osawa, Akihiro
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Kusachi, Shinya
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [35] Spectral X-ray computed tomography scanner using a cadmium telluride detector
    Sato, Eiichi
    Oda, Yasuyuki
    Yamaguchi, Satoshi
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Watanabe, Manabu
    Kusachi, Shinya
    RADIATION DETECTORS: SYSTEMS AND APPLICATIONS XVII, 2016, 9969
  • [36] A simulation study on the influence of scattered X-rays in energy-resolved computed tomography
    Tsai, Tien-Hsiu
    Kanno, Ikuo
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2017, 54 (02) : 205 - 212
  • [37] Seeing through Materials:X-Ray Imaging Using Computed Tomography
    Yisheng Miao
    Chengpeng Xue
    Xuelong Wu
    Zhongyao Li
    Junsheng Wang
    JournalofBeijingInstituteofTechnology, 2023, 32 (04) : 494 - 516
  • [38] RESPONSE OF SILICON DETECTOR FOR HIGH-ENERGY X-RAY COMPUTED-TOMOGRAPHY
    MIYAI, H
    KAWASAKI, S
    KITAGUCHI, H
    IZUMI, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 999 - 1003
  • [39] Conebeam X-ray computed tomography with an offset detector array
    Gregor, J
    Gleason, SS
    Paulus, MJ
    2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 803 - 806
  • [40] Monolithically integrated X-ray detector arrays for computed tomography
    Sudharsanan, R
    Yoganathan, M
    Vakerlis, G
    Ferekides, CS
    McCandless, B
    Birkmire, R
    Deych, R
    Luhta, R
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 573 - 578