Optical biometry of eyes corrected by phakic intraocular lenses

被引:9
|
作者
Pitault, G [1 ]
Leboeuf, C [1 ]
Jardins, SLL [1 ]
Auclin, F [1 ]
Chong-Sit, D [1 ]
Baudouin, C [1 ]
机构
[1] Ctr Hosp Natl Ophthalmol Quinze Vingts, Serv Ophtalmol 3, F-75012 Paris, France
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2005年 / 28卷 / 10期
关键词
biometry; IOL master; phakic intraocular lens; cataract;
D O I
10.1016/S0181-5512(05)81137-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to determine whether eye length measurements obtained with the IOL Master((R)) (Zeiss Humphrey) before and after phakic IOL implantation would show any changes. Methods: In a prospective study, we used the IOL Master((R)) to measure optical biometry in 25 myopic eyes of 15 patients before and after phakic IOL implantation (PRL(TM), ICL (TM), Artisan (TM)). The differences between both axial length measurements were calculated and compared using a nonparametric Wilcoxon test. Results: The difference between the preoperative and postoperative measurements ranged from -0,16 mm to 0,06 mm and averaged -0,016 mm, which was not statistically significant (p = 0.20). Both measurements correlated in a highly positive manner (r = 0.999; p < 0.0001). The reproducibility of the preoperative and postoperative axial length measurements was very high (coefficient of variation = 0.09% and 0.07%, respectively). The precision was 26 mu m for preoperative measurements and 19 lurn for postoperative measurements. Conclusion: Our results showed that postoperative measurements of axial length are highly comparable to preoperative measurements and that optical biometry can achieve highly precise and reliable axial length measurements in eyes with phakic IOLs. This application becomes clinically relevant in evaluating eyes with phakic IOLs that might require cataract surgery. Hence, accurate axial length measurements in eyes with phakic IOLs will be extremely important when cataract occurs in these eyes and when the preoperative measurements are no longer available.
引用
收藏
页码:1052 / 1057
页数:6
相关论文
共 50 条
  • [31] Magnification and accommodation with phakic intraocular lenses
    Langenbucher, Achim
    Szentmary, Nora
    Seitz, Berthold
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (03) : 295 - 302
  • [32] Phakic anterior chamber intraocular lenses
    Werner, L
    Apple, DJ
    Izak, AM
    Pandey, SK
    Trivedi, RH
    Macky, TA
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2001, 41 (03) : 133 - 152
  • [33] Phakic intraocular lenses: past and present
    Wissiak, Elfriede
    Lackner, Eva-Maria
    Vidic, Bertram
    Ardjomand, Navid
    SPEKTRUM DER AUGENHEILKUNDE, 2013, 27 (06) : 274 - 280
  • [34] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Ruiz-Moreno, JM
    Alió, JL
    Pérez-Santonja, JJ
    de la Hoz, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (03) : 270 - 275
  • [35] Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses
    Dejaco-Ruhswurm, I
    Scholz, U
    Pieh, S
    Hanselmayer, G
    Lackner, B
    Italon, C
    Ploner, M
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09): : 1589 - 1593
  • [36] Correction of high myopia by implantation of minus-power intraocular lenses in phakic eyes
    Wichmann, W
    JOURNAL OF REFRACTIVE SURGERY, 1996, 12 (06): : 672 - 673
  • [37] Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes
    Coskunseven, Efekan
    Kayhan, Belma
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (11) : e797 - e803
  • [38] Endothelial changes in phakic eyes with anterior chamber intraocular lenses to correct high myopia
    PerezSantonja, JJ
    Iradier, MT
    SanzIglesias, L
    Serrano, JM
    Zato, MA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (08): : 1017 - 1022
  • [39] The current status of phakic intraocular lenses
    Zaldivar, R
    Rocha, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1996, 36 (04) : 107 - 111
  • [40] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Kwok, AKH
    Young, AL
    Bhende, P
    Lam, DSC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 395 - 396