Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor

被引:286
|
作者
Fishman, KE [1 ]
Shannon, RV [1 ]
Slattery, WH [1 ]
机构
[1] HOUSE EAR RES INST, LOS ANGELES, CA 90057 USA
来源
关键词
cochlear implant; speech recognition; electrical stimulation; electrode number;
D O I
10.1044/jslhr.4005.1201
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Speech recognition was measured in listeners with the Nucleus-22 SPEAK speech processing strategy as a function of the number of electrodes. Speech stimuli were analyzed into 20 frequency bands and processed according to the usual SPEAK processing strategy. In the normal clinical processor each electrode is assigned to represent the output of one Filter. To create reduced-electrode processors the output of several adjacent filters were directed to a single electrode, resulting in processors with 1, 2, 4, 7, 10, and 20 electrodes. The overall spectral bandwidth was preserved, but the number of active electrodes was progressively reduced. After a 2-day period of adjustment to each processor, speech recognition performance was measured on medial consonants, vowels, monosyllabic words, and sentences. Performance with a single electrode processor was poor in all listeners, and average performance increased dramatically on all test materials as the number of electrodes was increased from 1 to 4. No differences in average performance were observed on any test in the 7-, 10-, and 20-electrode conditions. On sentence and consonant tests there was no difference between average performance with the 4-electrode and 20-electrode processors. This pattern of results suggests that cochlear implant listeners are not able to make Full use of the spectral information on all 20 electrodes. Further research is necessary to understand the reasons For this limitation and to understand how to increase the amount of spectral information in speech received by implanted listeners.
引用
收藏
页码:1201 / 1215
页数:15
相关论文
共 50 条
  • [41] Speech Intelligibility in Noise With a Pinna Effect Imitating Cochlear Implant Processor
    Wimmer, Wilhelm
    Weder, Stefan
    Caversaccio, Marco
    Kompis, Martin
    OTOLOGY & NEUROTOLOGY, 2016, 37 (01) : 19 - 23
  • [42] Design and simulation of a speech processor for cochlear implant based on Arabic language
    Al Zeyoudi, Fatima Ali
    Al Qaydi, Fatima Saeed
    Al Rashedi, Safa Salem
    Barhumi, Imad
    2009 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION TECHNOLOGY, 2009, : 178 - 179
  • [43] Speech perception with a cochlear implant sound processor incorporating loudness models
    McDermott, HJ
    Sucher, CM
    McKay, CM
    ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2005, 6 (01): : 7 - 13
  • [44] Selection of speech processor in cochlear implant patients: experience in a tertiary hospital
    Park, Sung-Min
    Chun, Yejun
    Choi, Byung Yoon
    ACTA OTO-LARYNGOLOGICA, 2024, 144 (02) : 91 - 95
  • [45] Companding to improve cochlear-implant speech recognition in speech-shaped noise
    Bhattacharya, Aparajita
    Zeng, Fan-Gang
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (02): : 1079 - 1089
  • [46] Speech recognition by normal-hearing and cochlear implant listeners as a function of intensity resolution
    Loizou, PC
    Dorman, M
    Poroy, O
    Spahr, T
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (05): : 2377 - 2387
  • [47] Cochlear Implant Melody Recognition as a Function of Melody Frequency Range, Harmonicity, and Number of Electrodes
    Singh, Sonya
    Kong, Ying-Yee
    Zeng, Fan-Gang
    EAR AND HEARING, 2009, 30 (02): : 160 - 168
  • [48] A SPEECH RECOGNITION PROCESSOR
    IWATA, T
    ISHIZUKA, H
    WATARI, M
    HOSHI, T
    KAWAKAMI, Y
    MIZUNO, M
    ISSCC DIGEST OF TECHNICAL PAPERS, 1983, 26 : 120 - &
  • [49] Speech Recognition and Cognitive Skills in Bimodal Cochlear Implant Users
    Hua, Hakan
    Johansson, Bjorn
    Magnusson, Lennart
    Lyxell, Bjorn
    Ellis, Rachel J.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2017, 60 (09): : 2752 - 2763
  • [50] Influence of Speech Rate on Auditory Recognition in Cochlear Implant Users
    de Sousa, Aline Faria
    da Costa, Lucas Bevilacqua Alves
    Costa, Maristela Julio
    Brito Neto, Rubens, V
    AUDIOLOGY AND NEUROTOLOGY, 2024, 29 (06) : 480 - 486