Integrated quantitative susceptibility and R2* mapping for evaluation of liver fibrosis: An ex vivo feasibility study

被引:10
|
作者
Jafari, Ramin [1 ,2 ]
Hectors, Stefanie J. [1 ]
Koehne de Gonzalez, Anne K. [3 ]
Spincemaille, Pascal [1 ]
Prince, Martin R. [1 ]
Brittenham, Gary M. [4 ]
Wang, Yi [1 ,2 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[2] Cornell Univ, Meinig Sch Biomed Engn, Ithaca, NY 14853 USA
[3] Columbia Univ, Dept Pathol, Med Ctr, New York, NY 10032 USA
[4] Columbia Univ, Dept Pediat, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
liver fibrosis; magnetic resonance imaging; quantitative susceptibility mapping; ENABLED DIPOLE INVERSION; SAMPLING VARIABILITY; CHRONIC HEPATITIS; IRON; MRI; FAT; QUANTIFICATION; COLLAGEN; DISEASE; BIOPSY;
D O I
10.1002/nbm.4412
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To develop a method for noninvasive evaluation of liver fibrosis, we investigated the differential sensitivities of quantitative susceptibility mapping (QSM) and R-2* mapping using corrections for the effects of liver iron. Liver fibrosis is characterized by excessive accumulation of collagen and other extracellular matrix proteins. While collagen increases R-2* relaxation, measures of R-2* for fibrosis are confounded by liver iron, which may be present in the liver over a wide range of concentrations. The diamagnetic collagen contribution to susceptibility values measured by QSM is much less than the contribution of highly paramagnetic iron. In 19 ex vivo liver explants with and without fibrosis, QSM (chi), R-2* and proton density fat fraction (PDFF) maps were constructed from multiecho gradient-recalled echo (mGRE) sequence acquisition at 3 T. Median parameter values were recorded and differences between the MRI parameters in nonfibrotic vs. advanced fibrotic/cirrhotic samples were evaluated using Mann-Whitney U tests and receiver operating characteristic analyses. Logistic regression with stepwise feature selection was employed to evaluate the utility of combined MRI measurements for detection of fibrosis. Median R-2* increased in fibrotic vs. nonfibrotic liver samples (P= .041), while differences in chi and PDFF were nonsignificant (P= .545 andP= .395, respectively). Logistic regression identified the combination of chi and R-2* significant for fibrosis detection (logit [prediction] = -8.45 + 0.23 R-2* - 28.8 chi). For this classifier, a highly significant difference between nonfibrotic vs. advanced fibrotic/cirrhotic samples was observed (P= .002). The model exhibited an AUC of 0.909 (P= .003) for detection of advanced fibrosis/cirrhosis, which was substantially higher compared with AUCs of the individual parameters (AUC 0.591-0.784). An integrated QSM and R-2* analysis of mGRE 3 T imaging data is promising for noninvasive diagnostic assessment of liver fibrosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quantitative susceptibility mapping of the human carotid artery: Assessing sensitivity to elastin and collagen ex vivo
    Stone, Alan J.
    Tornifoglio, Brooke
    Digeronimo, Francesco
    Shmueli, Karin
    Lally, Caitriona
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [42] Detection of Hepatic Fibrosis in Ex Vivo Liver Samples Using an Open-Photoacoustic-Cell Method: Feasibility Study
    S. Stolik
    D. A. Fabila
    J. M. de la Rosa
    G. Escobedo
    K. Suárez-Álvarez
    S. A. Tomás
    International Journal of Thermophysics, 2015, 36 : 2410 - 2416
  • [43] Detection of Hepatic Fibrosis in Ex Vivo Liver Samples Using an Open-Photoacoustic-Cell Method: Feasibility Study
    Stolik, S.
    Fabila, D. A.
    de la Rosa, J. M.
    Escobedo, G.
    Suarez-Alvarez, K.
    Tomas, S. A.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (09) : 2410 - 2416
  • [44] EVALUATION OF HIVINDUCED LIVER INFLAMMATION AND FIBROSIS USING A NOVEL EX VIVO HUMAN LIVER MODEL
    Wang, Yongtao
    Salloum, Shadi
    Leaker, Ben
    Sojoodi, Mozhdeh
    Eissa, Ibrahim
    Lin, Wenyu
    Xu, Min
    Alatrakchi, Nadia
    Reed, James
    Epstein, Eliana
    Eddy, Jonathan
    Dimowo, Oizoshimoshiofu
    Bach-Nielsen, Cecilie Siem
    Tanabe, Kenneth
    Lauer, Georg
    Chung, Raymond
    HEPATOLOGY, 2024, 80 : S1519 - S1520
  • [45] Quantitative susceptibility mapping and R1 measurement: Determination of the myelin volume fraction in the aging ex vivo rat corpus callosum
    Cho, Hwapyeong
    Lee, Hansol
    Gong, Yelim
    Kim, Young Ro
    Cho, Junghun
    Cho, Hyung Joon
    NMR IN BIOMEDICINE, 2022, 35 (03)
  • [46] Toward in vivo histology: A comparison of quantitative susceptibility mapping (QSM) with magnitude-, phase-, and R2*-imaging at ultra-high magnetic field strength
    Deistung, Andreas
    Schaefer, Andreas
    Schweser, Ferdinand
    Biedermann, Uta
    Turner, Robert
    Reichenbach, Juergen R.
    NEUROIMAGE, 2013, 65 : 299 - 314
  • [47] Quantitative liver iron measurement by magnetic resonance imaging: in vitro and in vivo assessment of the liver to muscle signal intensity and the R2*methods
    Virtanen, Johanna M.
    Komu, Markku E.
    Parkkola, Riitta K.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (08) : 1175 - 1182
  • [48] Susceptibility-weighted MR Imaging in the Grading of Liver Fibrosis: A Feasibility Study
    Balassy, Csilla
    Feier, Diana
    Peck-Radosavljevic, Markus
    Wrba, Friedrich
    Witoszynskyj, Stephan
    Kiefer, Berthold
    Reiter, Gert
    Dai, Yongming
    Ba-Ssalamah, Ahmed
    RADIOLOGY, 2014, 270 (01) : 149 - 158
  • [49] Quantitative susceptibility mapping of carotid arterial tissue ex vivo: Assessing sensitivity to vessel microstructural composition
    Stone, Alan J.
    Tornifoglio, Brooke
    Johnston, Robert D.
    Shmueli, Karin
    Kerskens, Christian
    Lally, Caitriona
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (05) : 2512 - 2527
  • [50] Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study
    Olivier Seror
    Matthieu Lepetit-Coiffé
    Bruno Quesson
    Hervé Trillaud
    Chrit T W Moonen
    European Radiology, 2006, 16 : 2265 - 2274