Good test-retest reliability of a paired-pulse transcranial magnetic stimulation protocol to measure short-interval intracortical facilitation

被引:9
|
作者
Qasem, H. [1 ]
Fujiyama, H. [1 ]
Rurak, B. K. [1 ]
Vallence, Ann-Maree [1 ]
机构
[1] Murdoch Univ, Coll Sci Hlth Engn & Educ, Discipline Psychol, 90 South St, Murdoch, WA 6150, Australia
基金
澳大利亚研究理事会;
关键词
Primary motor cortex; Transcranial magnetic stimulation; Short-interval intracortical facilitation; Reliability; Motor control; HUMAN MOTOR CORTEX; SHORT-LATENCY FACILITATION; I-WAVE INTERACTION; CORTICOSPINAL EXCITABILITY; INHIBITION; VARIABILITY; TMS; REPRODUCIBILITY; POTENTIALS; MODULATION;
D O I
10.1007/s00221-020-05926-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Transcranial magnetic stimulation (TMS) is used frequently to study human physiology, including the indirect-wave (I-wave) circuits generating short-interval intracortical facilitation (SICF). Growing evidence implicates SICF in plasticity and motor learning, suggesting that SICF is likely of functional relevance in both health and disease. To date, test-retest reliability has not been established for measures of SICF: given the clear potential of SICF to be used as a diagnostic tool, it is critical to establish the reliability of the paired-pulse TMS protocol to measure SICF. We investigated the test-retest reliability of SICF measured using paired-pulse TMS.SICF was measured in two sessions in 20 young adults using single- and paired-pulse TMS. Single-pulse TMS was set at an intensity that elicited MEPs of 1 mV (SI1mV) and paired-pulse TMS was set with the first stimulus at SI1mV, the second stimulus (S2) 90% of resting motor threshold (RMT), and a total of 20 interstimulus intervals (ISI; 1.1-4.9 ms with a 0.2 ms step). Large intraclass correlation coefficients (ICC) indicate good test-retest reliability between sessions for all SICF peaks (ICCs ranging from 0.73 to 0.79). The ISI at which SICF was maximal within individuals was consistent at all three peaks across both experimental sessions. Results showed good test-retest reliability of SICF at all three peaks when using a standard paired-pulse protocol to measure SICF. This finding suggests that paired-pulse TMS can be used to reliably probe the excitability of the interneuronal circuits that generate SICF. This provides a strong platform for future research to investigate the functional role of I-wave circuitry, including the role of I-wave circuitry in motor control decline in healthy older adults and individuals with movement disorders.
引用
收藏
页码:2711 / 2723
页数:13
相关论文
共 47 条
  • [21] Changes in Intracortical Excitability of Affected and Unaffected Hemispheres After Stroke Evaluated by Paired-Pulse Transcranial Magnetic Stimulation
    Seo, Ho Youn
    Kim, Gi-Wook
    Won, Yu Hui
    Park, Sung-Hee
    Seo, Jeong-Hwan
    Ko, Myoung-Hwan
    ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (04): : 495 - 501
  • [22] The effect of experimental pain on short-interval intracortical inhibition with multi-locus transcranial magnetic stimulation
    Salo, Karita S-T
    Vaalto, Selja M., I
    Koponen, Lari M.
    Nieminen, Jaakko O.
    Ilmoniemi, Risto J.
    EXPERIMENTAL BRAIN RESEARCH, 2019, 237 (06) : 1503 - 1510
  • [23] A new measure of cortical inhibition by mechanomyography and paired-pulse transcranial magnetic stimulation in unanesthetized rats
    Hsieh, Tsung-Hsun
    Dhamne, Sameer C.
    Chen, Jia-Jin J.
    Pascual-Leone, Alvaro
    Jensen, Frances E.
    Rotenberg, Alexander
    JOURNAL OF NEUROPHYSIOLOGY, 2012, 107 (03) : 966 - 972
  • [24] Increased intracortical inhibition in middle-aged humans;: a study using paired-pulse transcranial magnetic stimulation
    Kossev, AR
    Schrader, C
    Däuper, J
    Dengler, R
    Rollnik, JD
    NEUROSCIENCE LETTERS, 2002, 333 (02) : 83 - 86
  • [25] Characterisation of paired-pulse transcranial magnetic stimulation conditions yielding intracortical inhibition or I-wave facilitation using a threshold-hunting paradigm
    F. Awiszus
    Helmut Feistner
    Dietmar Urbach
    Hugh Bostock
    Experimental Brain Research, 1999, 129 : 317 - 324
  • [26] The Effects of Waveform and Current Direction on the Efficacy and Test-Retest Reliability of Transcranial Magnetic Stimulation
    Davila-Perez, Paula
    Jannati, Ali
    Fried, Peter J.
    Cudeiro, Javier
    Pascual-Leone, Alvaro
    NEUROSCIENCE, 2018, 393 : 97 - 109
  • [27] Effect of stimulus orientation and intensity on short-interval intracortical inhibition (SICI) and facilitation (SICF): A multi-channel transcranial magnetic stimulation study
    Tugin, Sergei
    Souza, Victor H.
    Nazarova, Maria A.
    Novikov, Pavel A.
    Tervo, Aino E.
    Nieminen, Jaakko O.
    Lioumis, Pantelis
    Ziemann, Ulf
    Nikulin, Vadim V.
    Ilmoniemi, Risto J.
    PLOS ONE, 2021, 16 (09):
  • [28] Characterisation of paired-pulse transcranial magnetic stimulation conditions yielding intracortical inhibition or I-wave facilitation using a threshold-hunting paradigm
    Awiszus, F
    Feistner, H
    Urbach, D
    Bostock, H
    EXPERIMENTAL BRAIN RESEARCH, 1999, 129 (02) : 317 - 324
  • [29] Test-retest reliability of transcranial magnetic stimulation measures of motor cortex organization and excitability
    Malcolm, MP
    Triggs, WJ
    Khandekar, G
    Light, KE
    NEUROLOGY, 2004, 62 (07) : A281 - A281
  • [30] Mapping of multiple muscles with transcranial magnetic stimulation: absolute and relative test-retest reliability
    Nazarova, Maria
    Novikov, Pavel
    Ivanina, Ekaterina
    Kozlova, Ksenia
    Dobrynina, Larisa
    Nikulin, Vadim V.
    HUMAN BRAIN MAPPING, 2021, 42 (08) : 2508 - 2528