Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophiesle

被引:12
|
作者
Nowinska, Anna K. [1 ,2 ]
Teper, Slawomir J. [1 ]
Janiszewska, Dominika A. [1 ,2 ]
Lyssek-Boron, Anita [2 ]
Dobrowolski, Dariusz [1 ,2 ]
Koprowski, Robert [3 ]
Wylegala, Edward [1 ]
机构
[1] Med Univ Silesia, Ophthalmol Clin, PL-40760 Katowice, Poland
[2] St Barbara Hosp, Dept Ophthalmol, PL-41200 Sosnowiec, Poland
[3] Univ Silesia, Dept Biomed Comp Syst, Sosnowiec, Poland
关键词
CHAMBER ANGLE MEASUREMENTS; IN-VIVO; ENDOTHELIAL DYSTROPHY; REPRODUCIBILITY; THICKNESS; REPEATABILITY; CLOSURE; ASSOCIATION; PHENOTYPE; DEPTH;
D O I
10.1155/2015/805367
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SSOCT measurements was demonstrated form CCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457
  • [12] Anterior Segment Angiography with 1050 nm Swept-Source Optical Coherence Tomography
    Li, Yan
    Lu, Chen D.
    Jia, Yali
    Lee, ByungKun
    Kraus, Martin F.
    Hornegger, Joachim
    Fujimoto, James G.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [13] Dynamic imaging of accommodation by swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Ruggeri, Marco
    Protti, Alessandra
    Lead, Rosachiara
    Gandolfi, Stefano A.
    Macaluso, Claudio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03): : 501 - 510
  • [14] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [15] Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography
    Arriola-Villalobos, Pedro
    Ignacio Fernandez-Vigo, Jose
    Diaz-Valle, David
    Almendral-Gomez, Jaime
    Fernandez-Perez, Cristina
    Benitez-del-Castillo, Jose M.
    CORNEA, 2017, 36 (02) : 183 - 188
  • [16] Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography
    Steinberg, Johannes
    Casagrande, Maria K.
    Frings, Andreas
    Katz, Toam
    Druchkiv, Vasyl
    Richard, Gisbert
    Linke, Stephan J.
    CORNEA, 2015, 34 (11) : 1413 - 1419
  • [17] VISUALIZATION OF THE MACULA IN GAS-FILLED EYES Spectral Domain Optical Coherence Tomography Versus Swept-Source Optical Coherence Tomography
    Ahn, Seong Joon
    Park, Seung Hoon
    Lee, Byung Ro
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (03): : 480 - 489
  • [18] Repeatability of Keratometry Measurements with Swept-Source Optical Coherence Tomography in Normal Eyes
    Poulsen, Anne
    Cui, Amy Lu David
    Seeger, Catherine
    Lehman, Erik
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [19] Anterior segment characteristics in normal and keratoconus eyes evaluated with a new type of swept-source optical coherence tomography
    Kim, Kook Young
    Lee, Seongjun
    Jeon, Young Joon
    Min, Ji Sang
    PLOS ONE, 2022, 17 (09):
  • [20] Defining the Clinical Role of Swept-Source Anterior Segment Optical Coherence Tomography in Eyes Undergoing Strabismus Surgery
    Pujari, Amar
    Patil, Vinay
    Chauhan, Nidhi
    Thangavel, Rajeswari
    Phuljhele, Swati
    Saxena, Rohit