Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophiesle

被引:12
|
作者
Nowinska, Anna K. [1 ,2 ]
Teper, Slawomir J. [1 ]
Janiszewska, Dominika A. [1 ,2 ]
Lyssek-Boron, Anita [2 ]
Dobrowolski, Dariusz [1 ,2 ]
Koprowski, Robert [3 ]
Wylegala, Edward [1 ]
机构
[1] Med Univ Silesia, Ophthalmol Clin, PL-40760 Katowice, Poland
[2] St Barbara Hosp, Dept Ophthalmol, PL-41200 Sosnowiec, Poland
[3] Univ Silesia, Dept Biomed Comp Syst, Sosnowiec, Poland
关键词
CHAMBER ANGLE MEASUREMENTS; IN-VIVO; ENDOTHELIAL DYSTROPHY; REPRODUCIBILITY; THICKNESS; REPEATABILITY; CLOSURE; ASSOCIATION; PHENOTYPE; DEPTH;
D O I
10.1155/2015/805367
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SSOCT measurements was demonstrated form CCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of Anterior Ocular Biometric Measurements Using Swept-Source and Time-Domain Optical Coherence Tomography
    Chen, Sisi
    Gao, Rongrong
    McAlinden, Colm
    Ye, Junming
    Wang, Yiran
    Chen, Min
    Huang, Jinhai
    Sun, Yong
    Yu, A-Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [2] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [3] Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
    Chansangpetch, Sunee
    Nguyen, Anwell
    Mora, Marta
    Badr, Mai
    He, Mingguang
    Porco, Travis C.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1554 - 1561
  • [4] Imaging the anterior eye segment by polarization-sensitive spectral-domain and swept-source optical coherence tomography
    Miura, Masahiro
    Yamanari, Masahiro
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844
  • [5] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Seyed Mohammad Ghoreishi
    Seyed Ali Akbar Mortazavi
    Zahra-Alsadat Abtahi
    Mohammad-Ali Abtahi
    Seyed Ali Sonbolestan
    Seyed-Hossein Abtahi
    Mohadeseh Mohammadinia
    Kimia Nekouie Isfahani
    International Ophthalmology, 2017, 37 : 965 - 971
  • [6] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [7] Comparison of Spectral-Domain and Swept-Source Optical Coherence Tomography Choroidal Thickness Measurements in Normal Eyes
    Luu, Jennifer Yen
    Sha, Patricia
    Durbin, Mary K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Agreement in anterior segment measurements between swept-source optical coherence and dual Scheimpflug tomography devices in keratoconus eyes
    Lee, Yunjin
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [9] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167
  • [10] Choroidal Analysis in Healthy Eyes Using Swept-Source Optical Coherence Tomography Compared to Spectral Domain Optical Coherence Tomography
    Adhi, Mehreen
    Liu, Jonathan J.
    Qavi, Ahmed H.
    Grulkowski, Ireneusz
    Lu, Chen D.
    Mohler, Kathrin J.
    Ferrara, Daniela
    Kraus, Martin F.
    Baumal, Caroline R.
    Witkin, Andre J.
    Waheed, Nadia K.
    Hornegger, Joachim
    Fujimoto, James G.
    Duker, Jay S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1272 - 1281