Deriving concentrations of oxygen and carbon in human tissues using single- and dual-energy CT for ion therapy applications

被引:51
|
作者
Landry, Guillaume [1 ]
Parodi, Katia [2 ]
Wildberger, Joachim E. [3 ]
Verhaegen, Frank [1 ,4 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, NL-6201 BN Maastricht, Netherlands
[2] Univ Munich, Dept Phys, Munich, Germany
[3] Maastricht Univ Med Ctr, Dept Radiol, Maastricht, Netherlands
[4] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 15期
关键词
CARLO DOSE CALCULATIONS; PROTON THERAPY; BIOLOGICAL TISSUES; NUMBERS; DISTRIBUTIONS; RADIOTHERAPY; PET; SEGMENTATION; VERIFICATION; TOMOGRAPHY;
D O I
10.1088/0031-9155/58/15/5029
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dedicated methods of in-vivo verification of ion treatment based on the detection of secondary emitted radiation, such as positron-emission-tomography and prompt gamma detection require high accuracy in the assignment of the elemental composition. This especially concerns the content in carbon and oxygen, which are the most abundant elements of human tissue. The standard single-energy computed tomography (SECT) approach to carbon and oxygen concentration determination has been shown to introduce significant discrepancies in the carbon and oxygen content of tissues. We propose a dual-energy CT (DECT)-based approach for carbon and oxygen content assignment and investigate the accuracy gains of the method. SECT and DECT Hounsfield units (HU) were calculated using the stoichiometric calibration procedure for a comprehensive set of human tissues. Fit parameters for the stoichiometric calibration were obtained from phantom scans. Gaussian distributions with standard deviations equal to those derived from phantom scans were subsequently generated for each tissue for several values of the computed tomography dose index (CTDIvol). The assignment of %weight carbon and oxygen (%wC,%wO) was performed based on SECT and DECT. The SECT scheme employed a HU versus %wC,O approach while for DECT we explored a Z(eff) versus %wC,O approach and a (Z(eff), rho(e)) space approach. The accuracy of each scheme was estimated by calculating the root mean square (RMS) error on %wC,O derived from the input Gaussian distribution of HU for each tissue and also for the noiseless case as a limiting case. The (Z(eff), rho(e)) space approach was also compared to SECT by comparing RMS error for hydrogen and nitrogen (%wH,%wN). Systematic shifts were applied to the tissue HU distributions to assess the robustness of the method against systematic uncertainties in the stoichiometric calibration procedure. In the absence of noise the (Z(eff), rho(e)) space approach showed more accurate %wC,O assignment (largest error of 2%) than the Z(eff) versus %wC,O and HU versus %wC,O approaches (largest errors of 15% and 30%, respectively). When noise was present, the accuracy of the (Z(eff), rho(e)) space (DECT approach) was decreased but the RMS error over all tissues was lower than the HU versus %wC,O (SECT approach) (5.8%wC versus 7.5%wC at CTDIvol = 20 mGy). The DECT approach showed decreasing RMS error with decreasing image noise (or increasing CTDIvol). At CTDIvol = 80 mGy the RMS error over all tissues was 3.7% for DECT and 6.2% for SECT approaches. However, systematic shifts greater than +/-5HU undermined the accuracy gains afforded by DECT at any dose level. DECT provides more accurate %wC,O assignment than SECT when imaging noise and systematic uncertainties in HU values are not considered. The presence of imaging noise degrades the DECT accuracy on %wC,O assignment but it remains superior to SECT. However, DECT was found to be sensitive to systematic shifts of human tissue HU.
引用
收藏
页码:5029 / 5048
页数:20
相关论文
共 50 条
  • [31] Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality
    Lukas Lenga
    Franziska Trapp
    Moritz H. Albrecht
    Julian L. Wichmann
    Addison A. Johnson
    Ibrahim Yel
    Tommaso D’Angelo
    Christian Booz
    Thomas J. Vogl
    Simon S. Martin
    European Radiology, 2019, 29 : 4603 - 4612
  • [32] Clinical photon-counting CT increases CT number precision and reduces patient size dependence compared to single- and dual-energy CT
    Flores, Jessica D.
    Poludniowski, Gavin
    Szum, Adrian
    Walther, Georg
    Lundberg, Johan
    Nowik, Patrik
    Granberg, Tobias
    BRITISH JOURNAL OF RADIOLOGY, 2025,
  • [33] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [34] Improvement of Breast Tumor Delineation for Preoperative Radiation Therapy Using Dual-Energy CT
    Noid, G.
    Currey, A. D.
    Bergom, C.
    Kelly, T. R.
    Wadhwa, A.
    Paulson, E. S.
    Basir, Z.
    Kong, A.
    Bovi, J. A.
    Tai, A.
    Gilat-Schmidt, T.
    Liu, Y.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E704 - E704
  • [35] Deep Learning-Based Dual-Energy CT Imaging Using Only a Single-Energy CT Data
    Zhao, W.
    Lv, T.
    Shen, L.
    Dai, X.
    Cheng, K.
    Jia, M.
    Chen, Y.
    Xing, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E276 - E276
  • [36] Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues
    Yang, M.
    Virshup, G.
    Clayton, J.
    Zhu, X. R.
    Mohan, R.
    Dong, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05): : 1343 - 1362
  • [37] Dual-energy CT shows brain ischemia and hyperbaric oxygen therapy efficacy in acute CO intoxication
    Uzkeser, Mustafa
    Kocak, Abdullah Osman
    Akbas, Ilker
    Polat, Gokhan
    Kantarci, Mecit
    Emet, Mucahit
    Aslan, Sahin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (07): : 1327.e3 - 1327.e4
  • [38] Impact of beam-hardening corrections on proton relative stopping power estimates from single- and dual-energy CT
    Chacko, Michael S.
    Wu, Dee
    Grewal, Hardev S.
    Sonnad, Jagadeesh R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09):
  • [39] Feasibility of Single Scan for Simultaneous Evaluation of Regional Krypton and Iodine Concentrations with Dual-Energy CT: An Experimental Study
    Hong, Sae Rom
    Chang, Suyon
    Im, Dong Jin
    Suh, Young Joo
    Hong, Yoo Jin
    Hur, Jin
    Kim, Young Jin
    Choi, Byoung Wook
    Lee, Hye-Jeong
    RADIOLOGY, 2016, 281 (02) : 597 - 605
  • [40] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133