Deriving concentrations of oxygen and carbon in human tissues using single- and dual-energy CT for ion therapy applications

被引:51
|
作者
Landry, Guillaume [1 ]
Parodi, Katia [2 ]
Wildberger, Joachim E. [3 ]
Verhaegen, Frank [1 ,4 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, NL-6201 BN Maastricht, Netherlands
[2] Univ Munich, Dept Phys, Munich, Germany
[3] Maastricht Univ Med Ctr, Dept Radiol, Maastricht, Netherlands
[4] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 15期
关键词
CARLO DOSE CALCULATIONS; PROTON THERAPY; BIOLOGICAL TISSUES; NUMBERS; DISTRIBUTIONS; RADIOTHERAPY; PET; SEGMENTATION; VERIFICATION; TOMOGRAPHY;
D O I
10.1088/0031-9155/58/15/5029
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dedicated methods of in-vivo verification of ion treatment based on the detection of secondary emitted radiation, such as positron-emission-tomography and prompt gamma detection require high accuracy in the assignment of the elemental composition. This especially concerns the content in carbon and oxygen, which are the most abundant elements of human tissue. The standard single-energy computed tomography (SECT) approach to carbon and oxygen concentration determination has been shown to introduce significant discrepancies in the carbon and oxygen content of tissues. We propose a dual-energy CT (DECT)-based approach for carbon and oxygen content assignment and investigate the accuracy gains of the method. SECT and DECT Hounsfield units (HU) were calculated using the stoichiometric calibration procedure for a comprehensive set of human tissues. Fit parameters for the stoichiometric calibration were obtained from phantom scans. Gaussian distributions with standard deviations equal to those derived from phantom scans were subsequently generated for each tissue for several values of the computed tomography dose index (CTDIvol). The assignment of %weight carbon and oxygen (%wC,%wO) was performed based on SECT and DECT. The SECT scheme employed a HU versus %wC,O approach while for DECT we explored a Z(eff) versus %wC,O approach and a (Z(eff), rho(e)) space approach. The accuracy of each scheme was estimated by calculating the root mean square (RMS) error on %wC,O derived from the input Gaussian distribution of HU for each tissue and also for the noiseless case as a limiting case. The (Z(eff), rho(e)) space approach was also compared to SECT by comparing RMS error for hydrogen and nitrogen (%wH,%wN). Systematic shifts were applied to the tissue HU distributions to assess the robustness of the method against systematic uncertainties in the stoichiometric calibration procedure. In the absence of noise the (Z(eff), rho(e)) space approach showed more accurate %wC,O assignment (largest error of 2%) than the Z(eff) versus %wC,O and HU versus %wC,O approaches (largest errors of 15% and 30%, respectively). When noise was present, the accuracy of the (Z(eff), rho(e)) space (DECT approach) was decreased but the RMS error over all tissues was lower than the HU versus %wC,O (SECT approach) (5.8%wC versus 7.5%wC at CTDIvol = 20 mGy). The DECT approach showed decreasing RMS error with decreasing image noise (or increasing CTDIvol). At CTDIvol = 80 mGy the RMS error over all tissues was 3.7% for DECT and 6.2% for SECT approaches. However, systematic shifts greater than +/-5HU undermined the accuracy gains afforded by DECT at any dose level. DECT provides more accurate %wC,O assignment than SECT when imaging noise and systematic uncertainties in HU values are not considered. The presence of imaging noise degrades the DECT accuracy on %wC,O assignment but it remains superior to SECT. However, DECT was found to be sensitive to systematic shifts of human tissue HU.
引用
收藏
页码:5029 / 5048
页数:20
相关论文
共 50 条
  • [1] Dual-Energy CT with Single- and Dual-Source Scanners: Current Applications in Evaluating the Genitourinary Tract
    Kaza, Ravi K.
    Platt, Joel F.
    Cohan, Richard H.
    Caoili, Elaine M.
    Al-Hawary, Mahmoud M.
    Wasnik, Ashish
    RADIOGRAPHICS, 2012, 32 (02) : 353 - 369
  • [2] Application of single- and dual-energy CT brain tissue segmentation to PET monitoring of proton therapy
    Berndt, Bianca
    Landry, Guillaume
    Schwarz, Florian
    Tessonnier, Thomas
    Kamp, Florian
    Dedes, George
    Thieke, Christian
    Wrl, Matthias
    Kurz, Christopher
    Ganswindt, Ute
    Verhaegen, Frank
    Debus, Juergen
    Belka, Claus
    Sommer, Wieland
    Reiser, Maximilian
    Bauer, Julia
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2427 - 2448
  • [3] Deep Learning Electronic Cleansing for Single- and Dual-Energy CT Colonography
    Tachibana, Rie
    Nappi, Janne J.
    Ota, Junko
    Kohlhase, Nadja
    Hironaka, Toru
    Kim, Se Hyung
    Regge, Daniele
    Yoshida, Hiroyuki
    RADIOGRAPHICS, 2018, 38 (07) : 2034 - 2050
  • [4] Single- and dual-energy CT with monochromatic synchrotron x-rays
    Dilmanian, FA
    Wu, XY
    Parsons, EC
    Ren, B
    Kress, J
    Button, TM
    Chapman, LD
    Coderre, JA
    Giron, F
    Greenberg, D
    Krus, DJ
    Liang, Z
    Marcovici, S
    Petersen, MJ
    Roque, CT
    Shleifer, M
    Slatkin, DN
    Thomlinson, WC
    Yamamoto, K
    Zhong, Z
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 371 - 387
  • [5] Advanced dual-energy CT applications for the evaluation of the soft tissues of the neck
    Forghani, R.
    Mukherji, S. K.
    CLINICAL RADIOLOGY, 2018, 73 (01) : 70 - 80
  • [6] Dual-energy CT for range prediction in proton and ion therapy
    Moehler, C.
    Wohlfahrt, P.
    Richter, C.
    Jaekel, O.
    Greilich, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S869 - S870
  • [7] VOXSI: A voxelized single- and dual-energy CT scenario generator for quantitative imaging
    van der Heyden, Brent
    Schyns, Lotte E. J. R.
    Podesta, Mark
    Vaniqui, Ana
    Almeida, Isabel P.
    Landry, Guillaume
    Verhaegen, Frank
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 47 - 52
  • [8] Comparison of proton range predictions between Single- and Dual-Energy CT using prompt gamma imaging
    Boon-Keng, T.
    Xie, Y.
    O'Grady, F.
    Lalonde, A.
    Petzoldt, J.
    Smeets, J.
    Janssens, G.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S95 - S96
  • [9] Comparison of single- and dual-energy CT combined with artificial intelligence for the diagnosis of pulmonary nodules
    Zhu, X.
    Zhu, L.
    Song, D.
    Wang, D.
    Wu, F.
    Wu, J.
    CLINICAL RADIOLOGY, 2023, 78 (02) : e99 - e105
  • [10] Material Separation Using Dual-Energy CT: Current and Emerging Applications
    Patino, Manuel
    Prochowski, Andrea
    Agrawal, Mukta D.
    Simeone, Frank J.
    Gupta, Rajiv
    Hahn, Peter F.
    Sahani, Dushyant V.
    RADIOGRAPHICS, 2016, 36 (04) : 1087 - 1105