Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

被引:17
|
作者
Shen, Junlin [1 ]
Du, Xiangying [1 ]
Guo, Daode [1 ]
Cao, Lizhen [1 ]
Gao, Yan [1 ]
Bai, Mei [2 ]
Li, Pengyu [1 ]
Liu, Jiabin [1 ]
Li, Kuncheng [1 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing 100053, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Dept Biomed Engn, Beijing 100053, Peoples R China
关键词
Iterative reconstruction; Coronary CT angiography; Radiation dose; IMAGE QUALITY; PROTOCOL;
D O I
10.1016/j.ejrad.2012.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17-35.08 HU) and Group 3 (34.34-35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [21] Tube current reduction and iterative image reconstruction for computed tomography myelography
    Paprottka, Karolin J.
    Schultz, Vivian
    Kupfer, Karina
    Beer, Meinrad
    Zimmer, Claus
    Kirschke, Jan S.
    Baum, Thomas
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [23] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [24] Dual-source CT coronary angiography: effectiveness of radiation dose reduction with lower tube voltage
    Sabarudin, Akmal
    Yusof, Ahmad Khairuddin Md
    Tay, May Fang
    Ng, Kwan-Hoong
    Sun, Zhonghua
    RADIATION PROTECTION DOSIMETRY, 2013, 153 (04) : 441 - 447
  • [25] Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
    Herzog, Christopher
    Mulvihill, Denise M.
    Nguyen, Shaun A.
    Savino, Giancarlo
    Schmidt, Bernhard
    Costello, Philip
    Vogl, Thomas J.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1232 - 1240
  • [26] Significant reduction of radiation dose using image noise reduction technology in coronary angiography and intervention
    Kastrati, M.
    Langenbrink, L.
    Piatkowski, M.
    Michaelsen, J.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 878 - 878
  • [27] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026
  • [28] Reduction in radiation exposure using a focused low-voltage scan before coronary CT angiography
    Al'Aref, Subhi J.
    Einstein, Andrew J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 246 - 248
  • [29] Radiation Dose Reduction in Coronary CT Angiography Time to Buckle Down
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (08) : 897 - 899
  • [30] Accuracy of coronary artery calcium scoring with tube current reduction by 75%, using an adaptive iterative reconstruction algorithm
    Luhur, Reny
    Schuijf, Joanne D.
    Mews, Jurgen
    Blobel, Jorg
    Ham, Bernd
    Lembcke, Alexander
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):