Intravenous fluid temperature management by infrared thermometer

被引:5
|
作者
Lapostolle, F [1 ]
Catineau, J [1 ]
Le Toumelin, P [1 ]
Proust, C [1 ]
Garrigue, B [1 ]
Galinski, M [1 ]
Adnet, F [1 ]
机构
[1] Hop Avicenne, EA 3409, SAMU, F-93009 Bobigny, France
来源
AMERICAN JOURNAL OF EMERGENCY MEDICINE | 2006年 / 24卷 / 02期
关键词
D O I
10.1016/j.ajem.2005.08.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The management of intravenous (IV) fluid temperature is a daily challenge in critical care, anesthesiology, and emergency medicine. Infusion of IV fluids at the right temperature partly influences clinical outcomes of critically ill patients. Nowadays, intravenous fluid temperature is poorly managed, as no suitable device is routinely available. Infrared (IR) thermorneters have been recently developed for industrial, personal, or medical purposes. The aim of this study was to evaluate the accuracy of an IR thermometer in measuring temperature of warmed and cooled infusion fluids in fluid bags. Methods: This study compared temperatures simultaneously recorded by an infrared thermometer and a temperature sensor. Temperatures of warmed (41 degrees C) and cooled (4 degrees C) infusion fluids in fluid bags were recorded by 2 independent operators every minute until IV bags' temperature reached ambient temperature. Results: The relation curve was established with 576 measures. Temperature measures performed with an IR thermometer were perfectly linear and perfectly correlated with the reference method (R-2 = 0.995, P < 10(-5)). Conclusion: Infrared thermometers are efficient to measure IV fluid bag temperature in the range of temperatures used in clinical practice. As these devices are easy to use and inexpensive, they could be largely used in critical care, anesthesiology, or emergency medicine. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:174 / 176
页数:3
相关论文
共 50 条
  • [31] Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
    Gasim G.I.
    Musa I.R.
    Abdien M.T.
    Adam I.
    BMC Research Notes, 6 (1)
  • [32] Development of In-Process Temperature Measurement of Grinding Surface with an Infrared Thermometer
    Ito, Yukio
    Kita, Yoshiyuki
    Fukuhara, Yoshiya
    Nomura, Mamoru
    Sasahara, Hiroyuki
    JOURNAL OF MANUFACTURING AND MATERIALS PROCESSING, 2022, 6 (02):
  • [33] Intravenous fluid management; an ongoing predicament
    Moussa, O. M.
    Corless, D. J.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 168 - 168
  • [34] INTRAVENOUS FLUID MANAGEMENT BY PEDIATRIC INTENSIVISTS
    Hassinger, Amanda
    Valentine, Stacey
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 153 - 153
  • [35] Comparison of forehead temperature screening with infrared thermometer and thermal imaging scanner
    Carpene, G.
    Henry, B. M.
    Mattiuzzi, C.
    Lippi, G.
    JOURNAL OF HOSPITAL INFECTION, 2021, 111 : 208 - 209
  • [36] Self-Calibrating Infrared Thermometer for Low-Temperature Measurement
    Barry, Tim
    Fuller, Gary
    Hayatleh, Khaled
    Lidgey, John
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (06) : 2047 - 2052
  • [37] DETERMINATION OF NORMAL EAR TEMPERATURE WITH AN INFRARED-EMISSION DETECTION THERMOMETER
    CHAMBERLAIN, JM
    TERNDRUP, TE
    ALEXANDER, DT
    SILVERSTONE, FA
    WOLFKLEIN, G
    ODONNELL, R
    GRANDNER, J
    ANNALS OF EMERGENCY MEDICINE, 1995, 25 (01) : 15 - 20
  • [38] Measurement of brood patch temperature of British passerines using an infrared thermometer
    Deeming, D. Charles
    Du Feu, Christopher R.
    BIRD STUDY, 2008, 55 : 139 - 143
  • [39] INFRARED TYMPANIC THERMOMETER - EVALUATION OF A NEW CLINICAL THERMOMETER
    SHINOZAKI, T
    DEANE, R
    PERKINS, FM
    CRITICAL CARE MEDICINE, 1988, 16 (02) : 148 - 150
  • [40] Temperature Variance between a Traceable Infrared Dual Laser Thermometer and Blood Product Core Temperature
    Willems, Shelly
    Carpenter, Erica
    Naczek, Christine
    Treml, Angela
    TRANSFUSION, 2020, 60 : 207A - 207A