Test for arsenic speciation in waters based on a paper-based analytical device with scanometric detection

被引:49
|
作者
Pena-Pereira, Francisco [1 ]
Villar-Blanco, Lorena [1 ]
Lavilla, Isela [1 ]
Bendicho, Carlos [1 ]
机构
[1] Univ Vigo, Fac Chem, Analyt & Food Chem Dept, Campus As Lagoas Marcosende S-N, Vigo 36310, Spain
关键词
Paper-based analytical device; Arsenic speciation; Non-instrumental detection; Scanometric analysis; Water analysis; Screening; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; MICROFLUIDIC DEVICES; HYDRIDE GENERATION; CELLULOSE FIBERS; ANALYTICAL-CHEMISTRY; AQUEOUS SAMPLES; DRINKING-WATER; PRECONCENTRATION; NANOPARTICLES;
D O I
10.1016/j.aca.2018.01.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, simple and affordable method for arsenic speciation analysis is described in this work. The proposed methodology involves in situ arsine generation, transfer of the volatile to the headspace and its reaction with silver nitrate at the detection zone of a paper-based analytical device (PAD). Thus, silver nitrate acts as a recognition element for arsine in the paper-based sensor. The chemical reaction between the recognition element and the analyte derivative results in the formation of a colored product which can be detected by scanning the detection zone and data treatment with an image processing and analysis program. Detection and injection zones were defined in the paper substrate by formation of hydrophobic barriers, thus enabling the formation of the volatile derivative without affecting the chemical stability of the recognition element present in the PAD. Experimental parameters influencing the analytical performance of the methodology, namely color mode detection, composition of the paper-based sensor and hydride generation and mass transfer conditions, were evaluated. Under optimal conditions, the proposed method showed limits of detection and quantification of 1.1 and 3.6 ng mL(-1), respectively. Remarkably, the limit of detection of the method reported herein was much lower than the maximum contaminant levels set by both the World Health Organization and the US Environmental Protection Agency for arsenic in drinking water, unlike several commercially available arsenic test kits. The repeatability, expressed as relative standard deviation, was found to be 7.1% (n = 8). The method was validated against the European Reference Material ERM (R)-CA615 groundwater and successfully applied to the determination of As(III), As(V) and total inorganic As in different water samples. Furthermore, the method can be used for the screening analysis of total arsenic in waters when a cut-off level of 7 ng mL(-1) is used. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Semi-quantitative microfluidic paper-based analytical device for ionic silica detection
    Mami Ogawa
    Aya Katoh
    Ryuichi Matsubara
    Haruka Kondo
    Mizuki Otsuka
    Tetsuya Sawatsubashi
    Yuki Hiruta
    Daniel Citterio
    Analytical Sciences, 2023, 39 : 1361 - 1370
  • [42] Colorimetric speciation of Cr on paper-based analytical devices based on field amplified stacking
    Zhai, Hui-Min
    Zhou, Ting
    Fang, Fang
    Wu, Zhi-Yong
    TALANTA, 2020, 210
  • [43] Simultaneous electrochemical detection in paper-based analytical devices
    Noviana, Eka
    Henry, Charles S.
    CURRENT OPINION IN ELECTROCHEMISTRY, 2020, 23 : 1 - 6
  • [44] An origami paper-based analytical device for DNA damage analysis
    Xue, Wei
    Zhao, Dan
    Zhang, Qiang
    Chang, Yangyang
    Liu, Meng
    CHEMICAL COMMUNICATIONS, 2021, 57 (87) : 11465 - 11468
  • [45] Bladder cancer hunting: A microfluidic paper-based analytical device
    Jiang, Qingyun
    Han, Tingting
    Ren, Haijun
    Aziz, Aziz Ur Rehman
    Li, Na
    Zhang, Hangyu
    Zhang, Zhengyao
    Liu, Bo
    ELECTROPHORESIS, 2020, 41 (16-17) : 1509 - 1516
  • [46] Text-Displaying Colorimetric Paper-Based Analytical Device
    Yamada, Kentaro
    Suzuki, Koji
    Citterio, Daniel
    ACS SENSORS, 2017, 2 (08): : 1247 - 1254
  • [47] Microfluidic Paper-Based Analytical Device for the Determination of Nitrite and Nitrate
    Jayawardane, B. Manori
    Wei, Shen
    McKelvie, Ian D.
    Kolev, Spas D.
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7274 - 7279
  • [48] Microfluidic Paper-Based Analytical Device for Aerosol Oxidative Activity
    Sameenoi, Yupaporn
    Panymeesamer, Pantila
    Supalakorn, Natcha
    Koehler, Kirsten
    Chailapakul, Orawon
    Henry, Charles S.
    Volckens, John
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (02) : 932 - 940
  • [49] A 3D microfluidic paper-based analytical device with smartphone-assisted colorimetric detection for iodine speciation in seaweed samples
    Placer, Lorena
    Lavilla, Isela
    Pena-Pereira, Francisco
    Bendicho, Carlos
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
  • [50] Paper-Based Microfluidic Device for Extracellular Lactate Detection
    Nan, Yan
    Zuo, Peng
    Ye, Bangce
    BIOSENSORS-BASEL, 2024, 14 (09):