Fault-Ride-Through Schemes of Grid-Interfaced DFIG: A comparative study under Symmetrical Grid Faults

被引:0
|
作者
Ali, S. M. [1 ]
Jawad, M. [1 ]
Ullah, Z. [1 ]
Khan, B. [1 ]
Mehmood, C. A. [1 ]
Farid, U. [1 ]
机构
[1] COMSATS IIT, Elect Engn, Abbottabad, Pakistan
关键词
Fault-Ride-Through (FRT); Wind energy; Doubly-Fed Induction Generator (DFIG); PI Control; Power control; FED INDUCTION GENERATOR; WIND TURBINES; ENHANCEMENT; CAPABILITY; STRATEGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The stabilized operation of Doubly Fed Induction Generator (DFIG) during symmetrical faults is a demanding problem for power system engineers. Transient peaks, oscillations, and higher-order frequency harmonics in DC link voltage and rotor circuitry will lead to the violations of the grid-code objectives during grid faults. Control actions must be taken to ensure safe operation of the Wind Energy Conversion System (WECS) during voltage sags/dips or short-circuit conditions without affecting system reliability. Based on the analysis, we propose a hybrid Fault-Ride-Through (FRT) strategy, considering grid-code specifications and converters control functions. Our work also presents a comparative and critical analysis of active FRT schemes under symmetrical faults. Moreover, our work discusses the effect of voltage and current parameters on the steady-state performance and stability of WECS. Furthermore, we analyze transient response of various performance parameters for the comparison of aforesaid schemes, such as rotor voltages and currents, DC link voltage, electromagnetic torque, active and reactive power support, and rotor speed. We used IEEE 5 Bus System interfaced with 9MW DFIG-Wind Turbine (WT) for the FRT performance evaluation in MATLAB/Simulink.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Capability of Asymmetrical Grid Faults Ride-through for DFIG-based Wind Turbines
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 3533 - 3540
  • [32] Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults
    Mohammadi, Jafar
    Afsharnia, Saeed
    Vaez-Zadeh, Sadegh
    Farhangi, Shahrokh
    IET RENEWABLE POWER GENERATION, 2016, 10 (08) : 1114 - 1122
  • [33] Improvement Low-Voltage Ride-Through Control of DFIG During Grid Faults
    Riouch, Tariq
    El-Bachtiri, Rachid
    2014 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2014, : 1596 - 1601
  • [34] A Comparative Analysis of Grid Forming and Grid Following Control Methodologies for Power Inverters Under Fault Ride Through Events
    Cakiroglu, Alper
    Akdemir, Huseyin
    Altm, Mufit
    Kasnakoglu, Cosku
    2024 INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES, SEST 2024, 2024,
  • [35] Converter Control During Low Voltage Ride Through Operation for Grid-Interfaced Solar PV Battery Assisted System
    Rai, Rashmi
    Singh, Bhim
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (09) : 9181 - 9191
  • [36] Fault-Ride through Improvement of DFIG under Symmetrical/Asymmetrical Voltage Dips
    Bekiroglu, Erdal
    Yazar, Muhammed Duran
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (05) : 510 - 523
  • [37] Current-Limiting Droop Controller with Fault-Ride-Through Capability for Grid-Tied Inverters
    Paspatis, A. G.
    Konstantopoulos, G. C.
    Mayfield, M.
    Nikolaidis, V. C.
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,
  • [38] Optimal control of DFIG wind turbines for load reduction under symmetrical grid fault
    Xu, Hao
    Hu, Shuju
    Song, Bin
    Xu, Honghua
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2014, (11): : 20 - 26
  • [39] Fault-ride-through strategies for grid-tied and grid-forming smart-transformers suited for islanding and interconnected operation
    Rodrigues, Justino
    Moreira, Carlos
    Lopes, Joao Pecas
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 189
  • [40] Fault-Ride-Through Approach for Grid-Tied Smart Transformers without Local Energy Storage
    Rodrigues, Justino
    Moreira, Carlos
    Lopes, Joao Pecas
    ENERGIES, 2021, 14 (18)