An algorithm for automatically detecting the pulse waveform of radial artery

被引:0
|
作者
Diao, Y [1 ]
Wu, SC [1 ]
Liu, YJ [1 ]
Zhang, S [1 ]
机构
[1] Beijing Univ Technol, Biomed Engn Ctr, Beijing 100022, Peoples R China
关键词
pulse wave; waveform detection; wavelet analysis;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A detecting algorithm of the pulse waveform of radial artery based on-continuous wavelet transform (CWT) is proposed in this paper. At present, the hemodynamic parameters can be detected widely by using, the instrument based on the pulse wave of radial artery. But operators a. re demanded to have some medical knowledge to artificially detect a waveform used to compute hemodynamic parameters, thus limiting its application.. As a result, we propose a new algorithm, making use of wavelet analysis, to detect pulse waveform of radial artery. Experiment results show that this algorithm has good accuracy, can improve the intelligence of hemodynamic parameters detecting instrument, and has simplify operation, which benefits popularization of hemodynamic parameters detection in family health care.
引用
收藏
页码:185 / 188
页数:4
相关论文
共 50 条
  • [21] Star algorithm: Detecting the ultrasonic endocardial boundary automatically
    Yao, W
    Tian, JM
    Zhao, BZ
    Chen, NN
    Qian, GZ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (07): : 943 - 951
  • [22] RESPIRATORY VARIATIONS IN PULSE OXIMETRY PLETHYSMOGRAPHIC WAVEFORM AMPLITUDE CALCULATED AUTOMATICALLY AND CONTINUOUSLY
    Novotni, D.
    Arnal, J. -M.
    Vanek, P.
    Lopez, R.
    Demory, D.
    Wysocki, M.
    INTENSIVE CARE MEDICINE, 2010, 36 : S350 - S350
  • [23] Estimation of central blood pressure using radial pulse waveform
    Wei, Ran
    Im, Jae Joong
    Park, Sung Ha
    Jung, Nam Sik
    2007 INTERNATIONAL SYMPOSIUM ON INFORMATION TECHNOLOGY CONVERGENCE, PROCEEDINGS, 2007, : 250 - +
  • [24] The differences in waveform between photoplethysmography pulse wave and radial pulse wave in movement station
    Li, Kun
    Zhang, Song
    Yang, Lin
    Luo, Zhichang
    Gu, Guanxiong
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 2657 - 2664
  • [25] Development of a Hybrid Force-Displacement Sensor Based on Fiber Bragg Grating for Radial Artery Pulse Waveform Measurement
    Tang, Zhongxin
    Wang, Shuxin
    Shi, Chaoyang
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 20045 - 20054
  • [26] Automatically detecting criminal identity deception: An adaptive detection algorithm
    Wang, G. Alan
    Chen, Hsinchun
    Xu, Jennifer J.
    Atabakhsh, Homa
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS, 2006, 36 (05): : 988 - 999
  • [27] TIB: A Time Management Algorithm of PDES for Automatically Detecting Concurrency
    Chen, Lili
    Yao, Yiping
    SIMUL: 2009 FIRST INTERNATIONAL CONFERENCE ON ADVANCES IN SYSTEM SIMULATION, 2009, : 138 - 143
  • [28] Algorithm for automatically producing layered sprites by detecting camera movement
    Jinzenji, K
    Ishibashi, S
    Kotera, H
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING - PROCEEDINGS, VOL I, 1997, : 767 - 770
  • [29] Monitoring cardiac output from the radial artery pressure waveform
    Orme, R. M. L'E.
    Pigott, D. W.
    ANAESTHESIA, 2007, 62 (01) : 90 - 91
  • [30] Model of radial artery based on human pulse
    Wang, Xuemin
    Yang, Cheng
    Lu, Xiaozuo
    Sun, Tao
    Zhou, Peng
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2013, 46 (06): : 487 - 492