Coriolis flowmeter damping for two-phase flow due to decoupling

被引:18
|
作者
Basse, Nils T. [1 ]
机构
[1] Siemens AS, Flow Instruments, Coriolisvej 1, DK-6400 Sonderborg, Denmark
关键词
Coriolis flowmeter; Damping theory; Two-phase flow; Decoupling; METERS;
D O I
10.1016/j.flowmeasinst.2016.09.005
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Coriolis flowmeters experience measurement errors due to both single- and two-phase flow. For two-phase flow, severe damping may occur, which leads to a (temporary) inability of the flowmeter to operate. The dominating part of the damping is caused by decoupling of the continuous and the dispersed phase. This paper presents the theory of damping due to decoupling in two-phase flow. Using a simple structural model, we provide examples of mixtures with water as the continuous phase. The dispersed phase is either air, or oil or sand.
引用
收藏
页码:40 / 52
页数:13
相关论文
共 50 条
  • [31] Mass flow measurement of oil-water two-phase flow based on coriolis flow meter and SVM
    Ma, Long-Bo
    Zhang, Hong-Jian
    Zhou, Hong-Liang
    He, Qing
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2007, 21 (02): : 200 - 205
  • [32] Damping measurements in tube bundles subjected to two-phase cross flow
    Moran, Joaquin E.
    Weaver, David S.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9, 2007, : 187 - 196
  • [33] Two-phase damping and interface surface area in tubes with internal flow
    Anscufter, Frangois
    Beguin, Cederic
    Ross, Annie
    Pettigrew, Michel J.
    Mureithi, Njuki W.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9, 2007, : 537 - 547
  • [35] On the Damping in Tube Arrays Subjected to Two-Phase Cross-Flow
    Moran, J. E.
    Weaver, D. S.
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2013, 135 (03):
  • [36] The effect of flow conditions on the sensitivity of the Coriolis flowmeter
    Bobovnik, G
    Kutin, J
    Bajsic, I
    FLOW MEASUREMENT AND INSTRUMENTATION, 2004, 15 (02) : 69 - 76
  • [37] Damping ratio and excitation force of a vibrating tube in two-phase flow
    Kawamura, Koji
    Yasuo, Akira
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2002, 68 (10): : 2872 - 2879
  • [38] Two-phase flow metering of heavy oil using a Coriolis mass flow meter: A case study
    Henry, Manus
    Tombs, Michael
    Duta, Mihaela
    Zhou, Feibiao
    Mercado, Ronaldo
    Kenyery, Frank
    Shen, Joseph
    Morles, Martin
    Garcia, Carlos
    Langansan, Robbie
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (06) : 399 - 413
  • [39] Matrix Pencil Method for Coriolis Mass Flow Meter Signal Processing in Two-Phase Flow Conditions
    Ibryaeva, O.
    Salov, D.
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [40] Volumetric flow rate measurement with capacitive electromagnetic flowmeter in oil-water two-phase flow
    Wang, Baoliang
    Fu, Yongfeng
    Huang, Zhiyao
    Li, Haiqing
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,