Coriolis flowmeter damping for two-phase flow due to decoupling

被引:18
|
作者
Basse, Nils T. [1 ]
机构
[1] Siemens AS, Flow Instruments, Coriolisvej 1, DK-6400 Sonderborg, Denmark
关键词
Coriolis flowmeter; Damping theory; Two-phase flow; Decoupling; METERS;
D O I
10.1016/j.flowmeasinst.2016.09.005
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Coriolis flowmeters experience measurement errors due to both single- and two-phase flow. For two-phase flow, severe damping may occur, which leads to a (temporary) inability of the flowmeter to operate. The dominating part of the damping is caused by decoupling of the continuous and the dispersed phase. This paper presents the theory of damping due to decoupling in two-phase flow. Using a simple structural model, we provide examples of mixtures with water as the continuous phase. The dispersed phase is either air, or oil or sand.
引用
收藏
页码:40 / 52
页数:13
相关论文
共 50 条
  • [1] Measurement of the Flow Rate of a Two-Phase Flow by a Coriolis Flowmeter
    Pushnov, A. V.
    MEASUREMENT TECHNIQUES, 2013, 56 (04) : 421 - 425
  • [2] Measurement of the Flow Rate of a Two-Phase Flow by a Coriolis Flowmeter
    A. V. Pushnov
    Measurement Techniques, 2013, 56 : 421 - 425
  • [3] Coriolis mass flowmeter works under two-phase flow
    不详
    HYDROCARBON PROCESSING, 2003, 82 (01): : 25 - +
  • [4] Performance study of Coriolis mass flowmeter for hydrogen two-phase flow measurement
    Pei, Xiangxiang
    Zhang, Xiaobin
    JOURNAL OF FLUIDS AND STRUCTURES, 2025, 133
  • [5] Coriolis Flowmeter for Two-Phase Flow Measurement Based on RS-Stacking Model
    Sun L.
    Zhao Z.
    Gao J.
    Zhang J.
    Shao X.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2023, 56 (11): : 1195 - 1204
  • [6] Damping of tubes due to internal two-phase flow
    Gravelle, A.
    Ross, A.
    Pettigrew, M. J.
    Mureithi, N. W.
    JOURNAL OF FLUIDS AND STRUCTURES, 2007, 23 (03) : 447 - 462
  • [7] Gas-liquid two-phase flow measurement by combining a Coriolis flowmeter with a flow conditioner and analytical models
    Meribout, Mahmoud
    Shehzad, Faisal
    Kharoua, Nabil
    Khezzar, Lyes
    MEASUREMENT, 2020, 163
  • [8] A neural network to correct mass flow errors caused by two-phase flow in a digital coriolis mass flowmeter
    Liu, RP
    Fuent, MJ
    Henry, MP
    Duta, MD
    FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (01) : 53 - 63
  • [9] Mass flowrate and water volume fraction measurements using Coriolis flowmeter in oil-water two-phase flow
    Zhang, Xiu-Gang
    Zhang, Qin-Ming
    Wang, Dong
    Lin, Zong-Hu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2004, 25 (06): : 983 - 985
  • [10] Damping of tubes with internal two-phase flow
    Gravelle, Alexandre
    Ross, Annie
    Pettigrew, Michel J.
    Mureithi, Njuki W.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9, 2007, : 563 - 571