Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers

被引:90
|
作者
Keller, Geoffray [1 ,2 ]
Cassar, Emmanuel [3 ]
Desebbe, Olivier [1 ,2 ]
Lehot, Jean-Jacques [1 ,2 ]
Cannesson, Maxime [1 ,2 ]
机构
[1] Louis Pradel Hosp, Hosp Civils Lyon, Dept Anesthesiol & Intens Care, Groupement Hosp Est, F-69500 Bron, France
[2] Univ Lyon 1, INSERM, ERI 22, F-69500 Bron, France
[3] Louis Pradel Hosp, Hosp Civils Lyon, Dept Cardiol, Groupement Hosp Est, F-69500 Bron, France
来源
CRITICAL CARE | 2008年 / 12卷 / 02期
关键词
D O I
10.1186/cc6822
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Pleth Variability Index (PVI) is a new algorithm that allows continuous and automatic estimation of respiratory variations in the pulse oximeter waveform amplitude. Our aim was to test its ability to detect changes in preload induced by passive leg raising (PLR) in spontaneously breathing volunteers. Methods We conducted a prospective observational study. Twenty-five spontaneously breathing volunteers were enrolled. PVI, heart rate and noninvasive arterial pressure were recorded. Cardiac output was assessed using transthoracic echocardiography. Volunteers were studied in three successive positions: baseline (semirecumbent position); after PLR of 45 with the trunk lowered in the supine position; and back in the semirecubent position. Results We observed significant changes in cardiac output and PVI during changes in body position. In particular, PVI decreased significantly from baseline to PLR (from 21.5 +/- 8.0% to 18.3 +/- 9.4%; P < 0.05) and increased significantly from PLR to the semirecumbent position (from 18.3 +/- 9.4% to 25.4 +/- 10.6 %; P < 0.05). A threshold PVI value above 19% was a weak but significant predictor of response to PLR (sensitivity 82%, specificity 57%, area under the receiver operating characteristic curve 0.734 +/- 0.101). Conclusion PVI can detect haemodynamic changes induced by PLR in spontaneously breathing volunteers. However, we found that PVI was a weak predictor of fluid responsiveness in this setting.
引用
收藏
页数:7
相关论文
共 43 条
  • [31] Predicting response to volume expansion during an ordeal of passive leg raising: a comparison between cardiac index variations and changes in blood pressure
    Rebet, O.
    Fischer, M-O
    Gerard, J-L
    Hanouz, J-L
    Fellahi, J-L
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A295 - A295
  • [32] Changes in Stroke Volume Variation Induced by Passive Leg Raising to Predict Fluid Responsiveness in Cardiac Surgical Patients With Protective Ventilation
    Ma, Guo-Guang
    Tu, Guo-Wei
    Zheng, Ji-Li
    Zhu, Du-Ming
    Hao, Guang-Wei
    Hou, Jun-Yi
    Su, Ying
    Luo, Jing-Chao
    Liu, Kai
    Luo, Zhe
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (06) : 1526 - 1533
  • [33] Dynamic changes of pulse pressure but not of pulse pressure variation during passive leg raising predict preload responsiveness in critically ill patients with spontaneous breathing activity
    Shi, Rui
    Moretto, Francesca
    Prat, Dominique
    Jacobs, Frederic
    Teboul, Jean-Louis
    Hamzaoui, Olfa
    JOURNAL OF CRITICAL CARE, 2022, 72
  • [34] Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically ventilated patients: a multicentre prospective observational study
    Mallat, Jihad
    Fischer, Marc-Olivier
    Granier, Maxime
    Vinsonneau, Christophe
    Jonard, Marie
    Mahjoub, Yazine
    Baghdadi, Fawzi Ali
    Preau, Sebastien
    Poher, Fabien
    Rebet, Olivier
    Bouhemad, Belaid
    Lemyze, Malcolm
    Marzouk, Mehdi
    Besnier, Emmanuel
    Hamed, Fadi
    Rahman, Nadeem
    Abou-Arab, Osama
    Guinot, Pierre-Gregoire
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (03) : 308 - 316
  • [35] Changes in arterial blood pressure induced by passive leg raising predict hypotension during the induction of sedation in critically ill patients without severe cardiac dysfunction
    YU Tao
    PAN Chun
    GUO Feng-mei
    YANG Yi
    QIU Hai-bo
    中华医学杂志(英文版), 2013, 126 (13) : 2445 - 2450
  • [36] Changes in arterial blood pressure induced by passive leg raising predict hypotension during the induction of sedation in critically ill patients without severe cardiac dysfunction
    Yu Tao
    Pan Chun
    Guo Feng-mei
    Yang Yi
    Qiu Hai-bo
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2445 - 2450
  • [37] Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?
    Temistocle Taccheri
    Francesco Gavelli
    Jean-Louis Teboul
    Rui Shi
    Xavier Monnet
    Critical Care, 25
  • [38] Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?
    Taccheri, Temistocle
    Gavelli, Francesco
    Teboul, Jean-Louis
    Shi, Rui
    Monnet, Xavier
    CRITICAL CARE, 2021, 25 (01)
  • [39] PASSIVE LEG RAISING-INDUCED CHANGES IN PEAK VELOCITY VARIATION OF LEFT VENTRICULAR OUTFLOW TRACT TO PREDICT FLUID RESPONSIVENESS IN POSTOPERATIVE CRITICALLY ILL ELDERLY PATIENTS
    Wan, Jing-jie
    Chen, Jun
    Xu, Li
    Peng, Ke
    Xie, Jin
    SHOCK, 2023, 60 (01): : 18 - 23
  • [40] Can Passive Leg Raising (PLR) Test Induced End-Tidal Carbon Dioxide (ETCO2) Changes Predict Fluid Responsiveness in Mechanically Ventilated Patients?
    Taggu, Alai
    CHEST, 2015, 148 (04)