Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers

被引:90
|
作者
Keller, Geoffray [1 ,2 ]
Cassar, Emmanuel [3 ]
Desebbe, Olivier [1 ,2 ]
Lehot, Jean-Jacques [1 ,2 ]
Cannesson, Maxime [1 ,2 ]
机构
[1] Louis Pradel Hosp, Hosp Civils Lyon, Dept Anesthesiol & Intens Care, Groupement Hosp Est, F-69500 Bron, France
[2] Univ Lyon 1, INSERM, ERI 22, F-69500 Bron, France
[3] Louis Pradel Hosp, Hosp Civils Lyon, Dept Cardiol, Groupement Hosp Est, F-69500 Bron, France
来源
CRITICAL CARE | 2008年 / 12卷 / 02期
关键词
D O I
10.1186/cc6822
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Pleth Variability Index (PVI) is a new algorithm that allows continuous and automatic estimation of respiratory variations in the pulse oximeter waveform amplitude. Our aim was to test its ability to detect changes in preload induced by passive leg raising (PLR) in spontaneously breathing volunteers. Methods We conducted a prospective observational study. Twenty-five spontaneously breathing volunteers were enrolled. PVI, heart rate and noninvasive arterial pressure were recorded. Cardiac output was assessed using transthoracic echocardiography. Volunteers were studied in three successive positions: baseline (semirecumbent position); after PLR of 45 with the trunk lowered in the supine position; and back in the semirecubent position. Results We observed significant changes in cardiac output and PVI during changes in body position. In particular, PVI decreased significantly from baseline to PLR (from 21.5 +/- 8.0% to 18.3 +/- 9.4%; P < 0.05) and increased significantly from PLR to the semirecumbent position (from 18.3 +/- 9.4% to 25.4 +/- 10.6 %; P < 0.05). A threshold PVI value above 19% was a weak but significant predictor of response to PLR (sensitivity 82%, specificity 57%, area under the receiver operating characteristic curve 0.734 +/- 0.101). Conclusion PVI can detect haemodynamic changes induced by PLR in spontaneously breathing volunteers. However, we found that PVI was a weak predictor of fluid responsiveness in this setting.
引用
收藏
页数:7
相关论文
共 43 条
  • [1] Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers
    Geoffray Keller
    Emmanuel Cassar
    Olivier Desebbe
    Jean-Jacques Lehot
    Maxime Cannesson
    Critical Care, 12
  • [2] Comparing Pleth variability index (PVI) variation induced by passive leg raising and Trendelenburg position in healthy volunteers
    Demirci, Osman Lutfi
    Isik, Gulsah Cikrikci
    Corbacioglu, Seref Kerem
    Cevik, Yunsur
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2020, 38 (02): : 278 - 281
  • [3] Detection of fluid responsiveness by changes of perfusion index and pleth-variability index during passive leg raising in spontaneously breathing post-surgical patients: a prospective interventional study
    Rauch, Simon
    Seraglio, Paolo Mario
    Cappello, Tomas Dal
    Roveri, Giulia
    Falk, Markus
    Bock, Matthias
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [4] Variations in pulse oximetry plethysmographic waveform amplitude induced by passive leg raising in spontaneously breathing volunteers
    Delerme, Samuel
    Renault, Robin
    Le Manach, Yannick
    Lvovschi, Virginie
    Bendahou, Mouhssine
    Riou, Bruno
    Ray, Patrick
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2007, 25 (06): : 637 - 642
  • [5] Changes in the Cardiac Index Induced by Unilateral Passive Leg Raising in Spontaneously Breathing Patients: A Novel Way to Assess Fluid Responsiveness
    Zhao, Zhiyong
    Zhang, Zhongwei
    Lin, Qionghua
    Shen, Lihua
    Wang, Pengmei
    Zhang, Shan
    Xia, Zhili
    Li, Fangfang
    Xing, Qian
    Zhu, Biao
    FRONTIERS IN MEDICINE, 2022, 9
  • [6] Relation between pulse oximetry plethysmographic waveform amplitude induced by passive leg raising and cardiac index in spontaneously breathing subjects
    Delerme, Samuel
    Castro, Samuel
    Freund, Yonathan
    Nazeyrollas, Pierre
    Josse, Marie-Odile
    Madonna-Py, Beatrice
    Rouff, Edwin
    Riou, Bruno
    Ray, Patrick
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (04): : 505 - 510
  • [7] Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device
    Matthieu Biais
    Lionel Vidil
    Philippe Sarrabay
    Vincent Cottenceau
    Philippe Revel
    François Sztark
    Critical Care, 13
  • [8] Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device
    Biais, Matthieu
    Vidil, Lionel
    Sarrabay, Philippe
    Cottenceau, Vincent
    Revel, Philippe
    Sztark, Francois
    CRITICAL CARE, 2009, 13 (06): : R195
  • [9] Pulse oximetry-derived pleth variability index can predict dexmedetomidine-induced changes in blood pressure in spontaneously breathing patients
    Sato, Makoto
    Kunisawa, Takayuki
    Kurosawa, Atsushi
    Sasakawa, Tomoki
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 318 - 324
  • [10] First Day of Life Reference Values for Pleth Variability Index in Spontaneously Breathing Term Newborns
    Latini, Giuseppe
    Dipaola, Lucia
    De Felice, Claudio
    NEONATOLOGY, 2012, 101 (03) : 179 - 182