EFFECT OF INCLINATION ON HEAT TRANSFER IN LARGE FLATTENED-TUBE STEAM CONDENSERS

被引:0
|
作者
Davies, William A. [1 ]
Kang, Yu [1 ]
Hrnjak, Pega [1 ,2 ]
Jacobi, Anthony M. [1 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Air Conditioning & Refrigerat Ctr ACRC, Urbana, IL 61801 USA
[2] CTS Creat Thermal Solut Inc, Urbana, IL USA
基金
美国国家科学基金会;
关键词
air-cooled condenser; inclination; heat transfer; condensation; flattened tube; FILM CONDENSATION; FLOW;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An experimental study of convective steam condensation inside a large, inclined, flattened-tube air-cooled condenser for power plants is presented. This is the second of a two-part study. The first part presents pressure drop and visualization results, while this study presents the experimental method along with heat transfer results. The condenser in this study is steel with brazed aluminum fins. The condenser measures 10.72m in length, with a cross section of 214 mm x 18 mm. The condenser tube was cut in half lengthwise and covered with a polycarbonate viewing window in order to provide visualization access simultaneously with the heat transfer measurements. Inlet steam mass flux ranged from 6.2 - 9.5 kg m(-2) s(-1), and condenser capacity varied from 25 31 kW. The angle of inclination was varied from horizontal to 75 downward. The experiments were performed with a uniform fin-face velocity of crossflowing air at 2.2 m/s. Condenser capacity was found to increase linearly with increasing downward inclination angle of the condenser, at a rate of 0.048% per degree of inclination below horizontal. This improvement was found to be the result of improved drainage and increased void fraction near the condenser outlet.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] EXPERIMENTAL STUDY OF THE EFFECT OF INCLINATION ANGLE ON THE HEAT TRANSFER CHARACTERISTICS OF STEAM CONDENSATION IN THE VERTICAL TUBE
    Liu, Jiabao
    Cao, Xiaxin
    Yang, Peixun
    PROCEEDINGS OF 2024 31ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 6, ICONE31 2024, 2024,
  • [12] Effect of tube inclination on pool boiling heat transfer
    Kang, MG
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 188 - 192
  • [13] HEAT-TRANSFER COEFFICIENTS OF STEAM CONDENSERS
    KURMARAO, PSV
    CHEMICAL ENGINEERING, 1980, 87 (17) : 112 - &
  • [14] EFFECT OF MATERIAL CHOICE ON HEAT-TRANSFER IN STEAM SURFACE CONDENSERS
    SPENCER, E
    MATERIALS PERFORMANCE, 1979, 18 (03) : 29 - 32
  • [15] Tube-side heat transfer and friction characteristics of titanium corrugated tubes used for steam condensers
    Kim, Nae-Hyun
    Go, Min-Geon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (09) : 4535 - 4543
  • [16] Tube-side heat transfer and friction characteristics of titanium corrugated tubes used for steam condensers
    Nae-Hyun Kim
    Min-Geon Go
    Journal of Mechanical Science and Technology, 2018, 32 : 4535 - 4543
  • [17] A new inundation correlation for the prediction of heat transfer in steam condensers
    Hu, Hong Gang
    Zhang, Chao
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2008, 54 (01) : 34 - 46
  • [18] Effect of inclination angle of lower tube on saturated pool boiling heat transfer of upper tube
    Kang, Myeong-Gie
    NUCLEAR ENGINEERING AND DESIGN, 2022, 388
  • [19] Effect of tube inclination angel on heat transfer characteristics of supercritical CO2 in tube
    Yang, Chuan-Yong
    Xu, Jin-Liang
    Wang, Xiao-Dong
    Zhang, Wei
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (09): : 1522 - 1528
  • [20] Influence of inclination angle on heat transfer performance of heat pipe radiator with an array of pulsating condensers
    Xiahou, Guowei
    Zhang, Shun
    Ma, Rui
    Zhang, Junjie
    He, Yecong
    APPLIED THERMAL ENGINEERING, 2021, 191