At-line near-infrared spectroscopy for monitoring concentrations in temperature-triggered glutamate fermentation

被引:11
|
作者
Liang, Jingbo [1 ]
Zhang, Dalong [1 ]
Guo, Xuan [1 ]
Xu, Qingyang [1 ]
Xie, Xixian [1 ]
Zhang, Chenglin [1 ]
Bai, Gang [2 ]
Xiao, Xue [2 ]
Chen, Ning [1 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Biotechnol, Educ Minist, Key Lab Ind Microbiol, Tianjin 300457, Peoples R China
[2] Nankai Univ, Coll Pharm, Tianjin 300071, Peoples R China
关键词
Near-infrared spectroscopy; Glutamate; Glucose; Lactate; Alanine; Multivariate calibration model; NIR SPECTROSCOPY; WINE; ACID; FEASIBILITY; PREDICTION;
D O I
10.1007/s00449-013-0962-y
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Rapid development in the glutamate fermentation industry has dictated the need for effective fermentation monitoring by rapid and precise methods that provide real-time information for quality control of the end-product. In recent years, near-infrared (NIR) spectroscopy and multivariate calibration have been developed as fast, inexpensive, non-destructive and environmentally safe techniques for industrial applications. The purpose of this study was to develop models for monitoring glutamate, glucose, lactate and alanine concentrations in the temperature-triggered process of glutamate fermentation. NIR measurements of eight batches of samples were analyzed by partial least-squares regression with several spectral pre-processing methods. The coefficient of determination (R (2)), model root-mean square error of calibration (RMSEC), root-mean square error of prediction (RMSEP) and residual predictive deviation (RPD) of the test calibration for the glutamate concentration were 0.997, 3.11 g/L, 2.56 g/L and 19.81, respectively. For the glucose concentration, R (2), RMSEC, RMSEP and RPD were 0.989, 1.37 g/L, 1.29 g/L and 9.72, respectively. For the lactate concentration, R (2), RMSEC, RMSEP and RPD were 0.975, 0.078 g/L, 0.062 g/L and 6.29, respectively. For the alanine concentration, R (2), RMSEC, RMSEP and RPD were 0.964, 0.213 g/L, 0.243 g/L and 5.29, respectively. New batch fermentation as an external validation was used to check the models, and the results suggested that the predictive capacity of the models for the glutamate fermentation process was good.
引用
收藏
页码:1879 / 1887
页数:9
相关论文
共 50 条
  • [31] Determination of moisture in hard gelatin capsules using near-infrared spectroscopy: Applications to at-line process control of pharmaceutics
    Berntsson, O
    Zackrisson, G
    Ostling, G
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) : 895 - 900
  • [32] On-line monitoring of the buffer capacity of particleboard furnish by near-infrared spectroscopy
    Andre, N.
    Young, T. M.
    Rials, T. G.
    APPLIED SPECTROSCOPY, 2006, 60 (10) : 1204 - 1209
  • [33] Use of near-infrared spectroscopy for on-line monitoring the quality of prepreg cloth
    Li, Wei
    Huang, Yu Dong
    Chen, Ping
    ADVANCED COMPOSITES LETTERS, 2008, 17 (02) : 41 - 48
  • [34] REAL TIME AND IN SITU NEAR-INFRARED SPECTROSCOPY (NIRS) FOR QUANTITATIVE MONITORING OF BIOMASS, GLUCOSE, ETHANOL AND GLYCERINE CONCENTRATIONS IN AN ALCOHOLIC FERMENTATION
    do Nascimento, R. J. A.
    de Macedo, G. R.
    dos Santos, E. S.
    de Oliveira, J. A.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (02) : 459 - 468
  • [35] Near-infrared spectroscopy for bioprocess monitoring and control
    Yeung, KSY
    Hoare, M
    Thornhill, NF
    Williams, T
    Vaghjiani, JD
    BIOTECHNOLOGY AND BIOENGINEERING, 1999, 63 (06) : 684 - 693
  • [36] Monitoring blood loss with near-infrared spectroscopy
    Torella, F
    Cowley, R
    McCollum, CN
    Thorniley, MS
    BRITISH JOURNAL OF SURGERY, 2001, 88 (05) : 753 - 753
  • [37] Implanted near-infrared spectroscopy for cardiac monitoring
    Bhunia, Sourav K.
    Cinbis, Can
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [38] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    Dunn, Jeffrey F.
    Zhang, Qiong
    Wu, Ying
    Srinivasan, Sathyanarayanan
    Smith, Michael R.
    Shaw, R. Anthony
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [39] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    University of Calgary, Experimental Imaging Centre, Faculty of Medicine, 3330 Hospital Drive NW, Calgary, AB T2N 4N1, Canada
    不详
    不详
    不详
    不详
    J Biomed Opt, 2008, 6
  • [40] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243