Distribution systems high impedance fault location: A spectral domain model considering parametric error processing

被引:32
|
作者
Nunes, J. U. N. [1 ]
Bretas, A. S. [2 ]
Bretas, N. G. [3 ]
Herrera-Orozco, A. R. [4 ]
Iurinic, L. U. [5 ]
机构
[1] Southern Fed Inst Educ Sci & Technol, Dept Elect Engn, BR-96015140 Pelotas, RS, Brazil
[2] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[3] Univ Sao Paulo, Dept Elect & Comp Engn, BR-13560480 Sao Carlos, SP, Brazil
[4] Technol Univ Pereira, Dept Elect Engn, Pereira 660003, Risaralda, Colombia
[5] Univ Reg Integrada Alto Uruguai & Missoes, Dept Comp Sci & Engn, BR-98400000 Frederico Westphalen, RS, Brazil
关键词
High-impedance fault; Fault location; Apparent impedance-based method; Least square method; Parametric error processing; ENHANCED PROTECTION SCHEME; LONG ARC; DISTANCE ESTIMATION; CIRCUIT ANALYSIS; IDENTIFICATION; ALGORITHM; DIAGNOSIS; LINES; AIR;
D O I
10.1016/j.ijepes.2019.02.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High impedance faults create specific technical challenges in the context of power system protection. The initial challenge is to detect these faults. If the fault is detected successfully, maintenance actions must be taken to avoid further risk to the population. The following technical challenge after detection is the location of these faults, which contributes significantly to the fast and safe restoration of the system. Although high impedance faults location is a topic of great concern, few studies are specifically devoted to this subject. This work presents an analytical formulation for the high impedance faults location in distribution systems. Initially, a system model which incorporates specific characteristics of this fault type is developed in the spectral domain. Using this model, the fault distance is estimated through a weighted least squares estimator associated with a parametric error processing algorithm. This algorithm detects the presence of parameter errors based on the composed measurement error in normalized form and further corrects the model. The validation of the presented technique is evaluated through comparative case studies considering the IEEE 13 node test feeder modeled in the Alternative Transient Program. Test results are encouraging indicating the formulation's potential for real-life applications.
引用
收藏
页码:227 / 241
页数:15
相关论文
共 50 条
  • [31] A double-ended third harmonic method for vegetation high impedance fault location in overhead distribution systems
    Gallas, Mairon
    Farias, Patrick Escalante
    Wontroba, Aldair
    Morais, Adriano Peres
    Vieira, Joa Paulo Abreu
    Rossini, Jean Pereira
    Junior, Ghendy Cardoso
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 231
  • [32] New impedance-based fault location method for unbalanced power distribution systems
    Alwash, Shamam F.
    Ramachandaramurthy, Vigna K.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (06): : 1008 - 1021
  • [33] A Comparison of Impedance-Based Fault Location Methods for Power Underground Distribution Systems
    Personal, Enrique
    Garcia, Antonio
    Parejo, Antonio
    Francisco Larios, Diego
    Biscarri, Felix
    Leon, Carlos
    ENERGIES, 2016, 9 (12):
  • [34] Impedance-Based Fault Location Technique for Distribution Systems in Presence of Distributed Generation
    Abo-Shady, F. M.
    Alaam, M. A.
    Azmy, Ahmed M.
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2013,
  • [35] Fault location algorithm for distribution systems with distributed generation based on impedance and metaheuristic methods
    Pessoa, Andre Luis da Silva
    Oleskovicz, Mario
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 225
  • [36] A new single end wideband impedance based fault location scheme for distribution systems
    Aboshady, F. M.
    Thomas, D. W. P.
    Sumner, Mark
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 173 : 263 - 270
  • [37] Application For The Analysis Of Low Impedance Fault Location Algorithms In Distribution Systems With Distributed Generation
    Giral-Ramirez, Diego Armando
    Guerrero, Luis Imbachi
    Hernandez-Suarez, Cesar Augusto
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2024, 27 (09): : 3173 - 3178
  • [38] Extended Impedance-Based Fault Location Formulation for Unbalanced Underground Distribution Systems
    Filomena, Andre D.
    Resener, Mariana
    Salim, Rodrigo H.
    Bretas, Arturo S.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4217 - 4224
  • [39] Fault Location in Distribution Systems: A Method Considering the Parameter Estimation Using a RNA Online
    Farias, P. E.
    Morais, A. P. D.
    Cardoso Junior, G.
    Rossini, J. P.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (12) : 4741 - 4749
  • [40] Wideband Synchronous Measurement-Based Detection and Location of High Impedance Fault for Resonant Distribution Systems With Integration of DERs
    Wei, Mingjie
    Shi, Fang
    Zhang, Hengxu
    Chen, Weijiang