The electromagnetic environment assessment of nuclear magnetic resonance device in hospital

被引:0
|
作者
Fu, Lu [1 ]
Yan, Zhaowen [1 ]
Shi, Guochang [1 ]
机构
[1] Beihang Univ, Dept Elect Informat Engn, Beijing, Peoples R China
来源
2012 10TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION & EM THEORY (ISAPE) | 2012年
关键词
electromagnetic environment; test; NMR device;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this paper is to assess electromagnetic environment of nuclear magnetic resonance (NMR) device in hospital, in considering of the proposed construction of subway lines which would pass the hospital. A method is proposed to quantitatively analyze and evaluate electromagnetic interference of NMR device. It is derived through the analysis and evaluation: when subway line passes through the hospital, the field strength surrounding the hospital can reach 30dBuT to 40dBuT at several frequencies, which is greater than 20dBuT-the threshold of the NMR device. It can ensure the NMR equipment working normally, after applying an electromagnetic shielding measure which makes sure that the electromagnetic shielding effectiveness reaches 80dB.
引用
收藏
页码:1099 / 1102
页数:4
相关论文
共 50 条
  • [21] Numerical method of designing nuclear magnetic resonance logging device sensor
    Hu Hai-Tao
    Xiao Li-Zhi
    Wu Xi-Ling
    ACTA PHYSICA SINICA, 2012, 61 (14)
  • [22] COMMUNICATION DEVICE FOR PATIENTS UNDERGOING NUCLEAR MAGNETIC-RESONANCE IMAGING
    ELLIS, JH
    DALLAS, CS
    RUSSELL, RJ
    RADIOLOGY, 1983, 149 (03) : 855 - 855
  • [24] Electromagnetic interference in the hospital environment
    Kimmel, William D.
    Gerke, Daryl D.
    Medical Device and Diagnostic Industry, 1995, 17 (05): : 97 - 101
  • [25] Characterization of the electromagnetic environment in a hospital
    Lauer, Oliver
    Riederer, Markus
    Karoui, Naceur
    Vahldieck, Ruediger
    Keller, Emanuela
    Froehlich, Juerg
    2008 ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 19TH INTERNATIONAL ZURICH SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, 2008, : 474 - +
  • [26] Quality assessment of Radix Codonopsis by quantitative nuclear magnetic resonance
    Li, Chia-Ying
    Xu, Hong-Xi
    Han, Quan-Bin
    Wu, Tian-Shung
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2124 - 2129
  • [27] Assessment of pomegranate postharvest quality using nuclear magnetic resonance
    Zhang, Lu
    McCarthy, Michael J.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2013, 77 : 59 - 66
  • [28] NONINVASIVE ARTERIAL PULSATILE BLOOD-FLOW OF THE LIMBS - ELECTROMAGNETIC DEVICE, NUCLEAR-MAGNETIC-RESONANCE BLOOD-FLOW SCANNER
    BOCCALON, H
    ADVANCES IN VASCULAR PATHOLOGY 1989, VOLS 1 & 2, 1989, 868 : 109 - 114
  • [29] NUCLEAR MAGNETIC RESONANCE
    PAKE, GE
    SOLID STATE PHYSICS, 1956, 2 : 1 - 91
  • [30] NUCLEAR MAGNETIC RESONANCE
    JONAS, J
    GUTOWSKY, HS
    ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1968, 19 : 447 - +