Sound Localization in Real-Time Vocoded Cochlear-Implant Simulations With Normal-Hearing Listeners

被引:12
|
作者
Ausili, Sebastian A. [1 ]
Backus, Bradford [2 ]
Agterberg, Martijn J. H. [1 ,3 ]
van Opstal, A. John [1 ]
van Wanrooij, Marc M. [1 ]
机构
[1] Radboud Univ Nijmegen, Dept Biophys, Donders Inst Brain Cognit & Behav, Nijmegen, Netherlands
[2] Oticon Med, Copenhagen, Denmark
[3] Radboud Univ Nijmegen, Med Ctr, Dept Otorhinolaryngol, Donders Inst Brain Cognit & Behav, Nijmegen, Netherlands
来源
TRENDS IN HEARING | 2019年 / 23卷
基金
欧洲研究理事会; 欧盟地平线“2020”;
关键词
cochlear implant; auditory perception; psychoacoustics; acoustic stimulation; QUALITY-OF-LIFE; SPEECH RECOGNITION; SPECTRAL CHANNELS; HEAD POSITION; HORIZONTAL-PLANE; SPATIAL RELEASE; STATIC EYE; EARS; NOISE; PERCEPTION;
D O I
10.1177/2331216519847332
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Bilateral cochlear-implant (CI) users and single-sided deaf listeners with a CI are less effective at localizing sounds than normal-hearing (NH) listeners. This performance gap is due to the degradation of binaural and monaural sound localization cues, caused by a combination of device-related and patient-related issues. In this study, we targeted the device-related issues by measuring sound localization performance of 11 NH listeners, listening to free-field stimuli processed by a real-time CI vocoder. The use of a real-time vocoder is a new approach, which enables testing in a free-field environment. For the NH listening condition, all listeners accurately and precisely localized sounds according to a linear stimulus-response relationship with an optimal gain and a minimal bias both in the azimuth and in the elevation directions. In contrast, when listening with bilateral real-time vocoders, listeners tended to orient either to the left or to the right in azimuth and were unable to determine sound source elevation. When listening with an NH ear and a unilateral vocoder, localization was impoverished on the vocoder side but improved toward the NH side. Localization performance was also reflected by systematic variations in reaction times across listening conditions. We conclude that perturbation of interaural temporal cues, reduction of interaural level cues, and removal of spectral pinna cues by the vocoder impairs sound localization. Listeners seem to ignore cues that were made unreliable by the vocoder, leading to acute reweighting of available localization cues. We discuss how current CI processors prevent CI users from localizing sounds in everyday environments.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Effects of rate and age in processing interaural time and level differences in normal-hearing and bilateral cochlear-implant listeners
    Anderson, Sean R.
    Easter, Kyle
    Goupell, Matthew J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 146 (05): : 3232 - 3254
  • [22] Effect of Vibrotactile Stimulation on Auditory Timbre Perception for Normal-Hearing Listeners and Cochlear-Implant Users
    Verma, Tushar
    Aker, Scott C.
    Marozeau, Jeremy
    TRENDS IN HEARING, 2023, 27
  • [23] Pulse-rate discrimination by cochlear-implant and normal-hearing listeners with and without binaural cues
    Carlyon, Robert P.
    Long, Christopher J.
    Deeks, John M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (04): : 2276 - 2286
  • [24] The Effects of Aging on Speech Perception in Noise: Comparison between Normal-Hearing and Cochlear-Implant Listeners
    Jin, Su-Hyun
    Liu, Chang
    Sladen, Douglas P.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2014, 25 (07) : 656 - 665
  • [25] Pulse-rate discrimination by cochlear-implant and normal-hearing listeners with and without binaural cues
    Carlyon, Robert P.
    Long, Christopher J.
    Deeks, John M.
    Journal of the Acoustical Society of America, 2008, 123 (04): : 2276 - 2286
  • [26] Sentence recognition in noise promoting or suppressing masking release by normal-hearing and cochlear-implant listeners
    Kwon, Bomjun J.
    Perry, Trevor T.
    Wilhelm, Cassie L.
    Healy, Eric W.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (04): : 3111 - 3119
  • [27] Effect of channel separation and interaural mismatch on fusion and lateralization in normal-hearing and cochlear-implant listeners
    Kan, Alan
    Goupell, Matthew J.
    Litovsky, Ruth Y.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 146 (02): : 1448 - 1463
  • [28] The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6-20 channels
    Dorman, MF
    Loizou, PC
    Fitzke, J
    Tu, ZM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (06): : 3583 - 3585
  • [29] Recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6-20 channels
    Dorman, Michael F.
    Loizou, Philipos C.
    Fitzke, Jeanette
    Tu, Zhemin
    Journal of the Acoustical Society of America, 1998, 104 (06):
  • [30] Role of semantic context and talker variability in speech perception of cochlear-implant users and normal-hearing listeners
    O'Neill, Erin R.
    Parke, Morgan N.
    Kreft, Heather A.
    Oxenham, Andrew J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 149 (02): : 1224 - 1239