Relationship between Cortical Bone Thickness and Cancellous Bone Density at Dental Implant Sites in the Jawbone

被引:29
|
作者
Wang, Shiuan-Hui [1 ]
Shen, Yen-Wen [2 ,3 ]
Fuh, Lih-Jyh [2 ,3 ]
Peng, Shin-Lei [4 ]
Tsai, Ming-Tzu [5 ]
Huang, Heng-Li [2 ,6 ]
Hsu, Jui-Ting [2 ,6 ]
机构
[1] China Med Univ, Master Program Biomed Engn, Taichung 404, Taiwan
[2] China Med Univ, Sch Dent, Taichung 404, Taiwan
[3] China Med Univ & Hosp, Dept Dent, Taichung 404, Taiwan
[4] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 404, Taiwan
[5] Hungkuang Univ, Dept Biomed Engn, Taichung 433, Taiwan
[6] Asia Univ, Dept Bioinformat & Med Engn, Taichung 413, Taiwan
关键词
jawbone; cancellous bone density; cortical bone thickness; dental cone-beam computed tomography; dental implant site; BEAM COMPUTED-TOMOGRAPHY; PRIMARY STABILITY; TRABECULAR BONE; DIFFERENT REGIONS; VOXEL VALUES; MULTISLICE; IMMEDIATE; QUALITY; CT;
D O I
10.3390/diagnostics10090710
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implant surgery is a common treatment for missing teeth. Its survival rate is considerably affected by host bone quality and quantity, which is often assessed prior to surgery through dental cone-beam computed tomography (CBCT). Dental CBCT was used in this study to evaluate dental implant sites for (1) differences in and (2) correlations between cancellous bone density and cortical bone thickness among four regions of the jawbone. In total, 315 dental implant sites (39 in the anterior mandible, 42 in the anterior maxilla, 107 in the posterior mandible, and 127 in the posterior maxilla) were identified in dental CBCT images from 128 patients. All CBCT images were loaded into Mimics 15.0 to measure cancellous bone density (unit: grayscale value (GV) and cortical bone thickness (unit: mm)). Differences among the four regions of the jawbone were evaluated using one-way analysis of variance and Scheffe's posttest. Pearson coefficients for correlations between cancellous bone density and cortical bone thickness were also calculated for the four jawbone regions. The results revealed that the mean cancellous bone density was highest in the anterior mandible (722 +/- 227 GV), followed by the anterior maxilla (542 +/- 208 GV), posterior mandible (535 +/- 206 GV), and posterior maxilla (388 +/- 206 GV). Cortical bone thickness was highest in the posterior mandible (1.15 +/- 0.42 mm), followed by the anterior mandible (1.01 +/- 0.32 mm), anterior maxilla (0.89 +/- 0.26 mm), and posterior maxilla (0.72 +/- 0.19 mm). In the whole jawbone, a weak correlation (r= 0.133,p= 0.041) was detected between cancellous bone density and cortical bone thickness. Furthermore, except for the anterior maxilla (r= 0.306,p= 0.048), no correlation between the two bone parameters was observed (allp> 0.05). Cancellous bone density and cortical bone thickness varies by implant site in the four regions of the jawbone. The cortical and cancellous bone of a jawbone dental implant site should be evaluated individually before surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Relationship of Bone Mineralization Density Distribution (BMDD) in Cortical and Cancellous Bone Within the Iliac Crest of Healthy Premenopausal Women
    B. M. Misof
    D. W. Dempster
    Hua Zhou
    P. Roschger
    N. Fratzl-Zelman
    P. Fratzl
    S. J. Silverberg
    E. Shane
    A. Cohen
    E. Stein
    T. L. Nickolas
    R. R. Recker
    J. Lappe
    J. P. Bilezikian
    K. Klaushofer
    Calcified Tissue International, 2014, 95 : 332 - 339
  • [32] Relationship of Bone Mineralization Density Distribution (BMDD) in Cortical and Cancellous Bone Within the Iliac Crest of Healthy Premenopausal Women
    Misof, B. M.
    Dempster, D. W.
    Zhou, Hua
    Roschger, P.
    Fratzl-Zelman, N.
    Fratzl, P.
    Silverberg, S. J.
    Shane, E.
    Cohen, A.
    Stein, E.
    Nickolas, T. L.
    Recker, R. R.
    Lappe, J.
    Bilezikian, J. P.
    Klaushofer, K.
    CALCIFIED TISSUE INTERNATIONAL, 2014, 95 (04) : 332 - 339
  • [33] Stress and strain distribution behavior in the bone due to the effect of cancellous bone, dental implant material and the bone height
    Hedia, HS
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2002, 12 (02) : 111 - 119
  • [34] Osteocyte lacunar density decreases with age: Differences between cortical and cancellous bone.
    Ovesel, D
    Melsen, F
    Eriksen, EF
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (04) : 809 - 809
  • [35] Osteocyte lacunar density decreases with age: Differences between cortical and cancellous bone.
    Ovesel, D
    Melsen, F
    Eriksen, EF
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S467 - S467
  • [36] The Bindex® ultrasound device: reliability of cortical bone thickness measures and their relationship to regional bone mineral density
    Behrens, Martin
    Felser, Sabine
    Mau-Moeller, Anett
    Weippert, Matthias
    Pollex, Johannes
    Skripitz, Ralf
    Herlyn, Philipp K. E.
    Fischer, Dagmar-C
    Bruhn, Sven
    Schober, Hans-Christof
    Zschorlich, Volker
    Mittlmeier, Thomas
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (09) : 1528 - 1540
  • [37] Correlation Between Distal Radial Cortical Thickness and Bone Mineral Density
    Webber, Tracy
    Patel, Shaun P.
    Pensak, Michael
    Fajolu, Olukemi
    Rozental, Tamara D.
    Wolf, Jennifer Moriatis
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03): : 493 - 499
  • [38] Relationship between carotid plaque thickness and bone mineral density
    Park, J. -H.
    Suk, S. -H.
    Koh, I. -S.
    CEREBROVASCULAR DISEASES, 2015, 39 : 25 - 25
  • [39] Relationship Between Prepatellar Fat Thickness and Bone Mineral Density
    Agir, Hatice
    Orhan, Ozlem
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2024, 34 (05): : 533 - 538
  • [40] Influence of cortical bone quality on stress distribution in bone around dental implant
    Kitagawa, T
    Tanimoto, Y
    Nemoto, K
    Aida, M
    DENTAL MATERIALS JOURNAL, 2005, 24 (02) : 219 - 224